Publications by authors named "Thibaud Lacour"

Gender-differences in survival following transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) have been suggested. The objective of this study was to analyze outcomes following TAVR according to gender and to compare outcomes between TAVR and SAVR in women, at a nationwide level. Based on the French administrative hospital-discharge database, the study collected information for all consecutive patients treated with TAVR and SAVR between 2010 and 2019.

View Article and Find Full Text PDF

Background: Conduction abnormalities following transcatheter aortic valve replacement (TAVR) often may require permanent pacemaker implantation (PPM).

Objective: The purpose of this study was to evaluate outcomes associated with PPM after a TAVR procedure in a large, nationwide-level population.

Methods: Based on the administrative hospital discharge database, the incidence of all-cause death, cardiovascular death, and hospitalization for heart failure (HF) were retrospectively collected, based on the presence or absence of PPM, in the first 30 days following all TAVRs in France from 2010 to 2019.

View Article and Find Full Text PDF

Background: Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) and redo surgical aortic valve replacement (SAVR) represent the 2 treatments for aortic bioprosthesis failure. Clinical comparison of both therapies remains limited by the number of patients analyzed.

Objectives: The purpose of this study was to analyze the outcomes of VIV TAVR versus redo SAVR at a nationwide level in France.

View Article and Find Full Text PDF

Risk-benefit assessment for transcatheter aortic valve implantation (TAVI) is still a matter of debate. We aimed to identify patients with a bad outcome within 1 year after TAVI, and to develop a Futile TAVI Simple score (FTS). Based on the administrative hospital-discharge database, all consecutive patients treated with percutaneous TAVI in France between 2010 and 2018 were included.

View Article and Find Full Text PDF

Background: Valve-in-valve transcatheter aortic valve implantation (TAVI) has emerged as a treatment for aortic bioprosthesis failure in case of prohibitive risk for redo surgery. However, clinical evaluation of valve-in-valve TAVI remains limited by the number of patients analysed.

Aim: To evaluate outcomes of valve-in-valve TAVI compared with native aortic valve TAVI at a nationwide level in France.

View Article and Find Full Text PDF

Important health resources are dedicated worldwide to the management of COVID-19. This new disease, due to its large diffusion, may significantly hamper the prognosis of other pathologies, such as ST-segment elevation myocardial infarction (STEMI) because of (a) a possible direct negative impact and (b) shortage of first response medical resources and increased delays to reperfusion. We report the case of a 68-year-old man admitted for anterior STEMI and asymptomatic COVID-19.

View Article and Find Full Text PDF

Aims: The aim of this study was to describe the midterm outcomes in nonagenarians undergoing transcatheter aortic valve implantation (TAVI).

Methods And Results: Based on the French administrative hospital discharge database, the study collected information for all consecutive patients with aortic stenosis (AS), and specifically those treated with TAVI between 2010 and 2018. Cox regression was used for the analysis of predictors of events.

View Article and Find Full Text PDF

Background: Two competing transcatheter aortic valve replacement (TAVR) technologies are currently available. Head-to-head comparisons of the relative performances of these 2 devices have been published. However, long-term clinical outcome evaluation remains limited by the number of patients analyzed, in particular, for recent-generation devices.

View Article and Find Full Text PDF

Introduction: We sought to develop an efficient method to upgrade pacing-induced cardiomyopathy (PICM) patients from a leadless pacemaker (LPM) to cardiac resynchronization therapy.

Methods And Results: Three consecutive patients with chronic atrial fibrillation, implanted with an LPM, with permanent right ventricular pacing, and who developed left ventricular systolic dysfunction due to PICM, were included. A conventional biventricular pacemaker with two different coronary sinus leads, one used for left lateral ventricular pacing, one for early right ventricular sensing, was implanted.

View Article and Find Full Text PDF