Publications by authors named "Thevenot D"

Unlabelled: The presence of highly pathogenic Shiga-toxin-producing Escherichia coli (STEC) in shellfish, upstream waters and sediment from coastal shellfish sites was evaluated using the ISO/TS-13136 method. Shellfish (oysters, mussels and cockles), water and sediment samples were collected monthly over a period of 1 year. The method used real-time PCR detection of stx1, stx2 and eae genes and genetic markers corresponding to the five major serogroups (O157, O26, O103, O111 and O145) on enrichment broths and the identification of STEC when these genes and markers were detected.

View Article and Find Full Text PDF

This study was designed to evaluate the capacity of three Hafnia strains to inhibit the growth of an E. coli strain O26:H11 in an uncooked pressed model cheese, in the presence or absence of a microbial consortium added to mimic a cheese microbial community. Inoculated at 2 log CFU/ml into pasteurized milk without Hafnia, the E.

View Article and Find Full Text PDF

The involvement of the pathogenic Shiga-toxin-producing Escherichia coli (STEC; also called verocytotoxic-producing E. coli or VTEC) in sporadic cases and disease outbreaks is presently increasing. Infrequent cases are due to ingestion of milk and dairy products.

View Article and Find Full Text PDF

Background: On 22 June 2011, 8 patients with hemolytic uremic syndrome (HUS) or bloody diarrhea were reported in France. All 8 were attendees of a community center event on 8 June near Bordeaux. Three Escherichia coli cases were confirmed by isolation of Shiga toxin-producing E.

View Article and Find Full Text PDF

Aims: Our main objective was to optimize the enrichment of Escherichia coli O26 in raw milk cheeses for their subsequent detection with a new automated immunological method.

Methods And Results: Ten enrichment broths were tested for the detection of E. coli O26.

View Article and Find Full Text PDF

Enterohemorrhagic Escherichia coli O157:H7 is an important pathogen associated with infections caused by consumption of undercooked raw meat. Sensitive and rapid detection methods for E. coli O157:H7 are essential for the meat industry to ensure a safe meat supply.

View Article and Find Full Text PDF

Growth and survival of acid-resistant (AR) and non-acid-resistant (NAR) Shiga-toxin-producing Escherichia coli (STEC) strains were investigated during the manufacture and ripening of microfiltered milk Camembert cheeses. The induction of acid resistance of the STEC strains in cheeses was also studied. Six different mixtures of AR and/or NAR STEC strains were inoculated separately into microfiltered milk at a level of 10(3) CFU mL(-1).

View Article and Find Full Text PDF

Both pathogenic and nonpathogenic E. coli exhibit a stress response to sublethal environmental stresses. Several studies have reported acid tolerance and survival characteristics of E.

View Article and Find Full Text PDF

The Driver-Pressures-State-Impact-Response approach is applied to heavy metals in the Seine River catchment (65,000 km(2); 14 million people of which 10 million are aggregated within Paris megacity; 30% of French industrial and agricultural production). The contamination pattern at river mouth is established on the particulate material at different time scales: 1930-2000 for floodplain cores, 1980-2003 for suspended particulate matter (SPM) and bed-sediments, 1994-2003 for atmospheric fallout and annual flood deposits. The Seine has been among the most contaminated catchments with maximum contents recorded at 130 mg kg(-1) for Cd, 24 for Hg, 558 for Pb, 1620 for Zn, 347 for Cu, 275 for Cr and 150 for Ni.

View Article and Find Full Text PDF

River basin metal pollution originates from heavy industries (plating, automobile) and from urban sources (Paris conurbation: 2740 km(2), 9.47 million inhabitants). The natural sources of metal have been found to be limited due to sedimentary nature of this catchment and to the very low river sediment transport (10 t km(-2) y(-1)).

View Article and Find Full Text PDF

The purpose of this study was dual: 1. to evaluate the serotype distribution of 1028 Listeria monocytogenes isolates collected in 13 French salting factories and their products and 2. to identify sources of L.

View Article and Find Full Text PDF

Pork meat and processed pork products have been the sources of outbreaks of listeriosis in France and in other European countries during the last decade. The aim of this review is to understand how contamination, survival and growth of Listeria monocytogenes can occur in pork meat products. This study discusses the presence of L.

View Article and Find Full Text PDF

Total atmospheric deposition, i.e. both wet and dry ones, was sampled during three different sampling periods between 1994 and 2002.

View Article and Find Full Text PDF

The aims of the present study were: (i) to investigate the occurrence of Listeria monocytogenes in dried sausage processing plants on surfaces before and during processing, (ii) to study the contamination in meat and sausages at different stages of maturation, (iii) to assess the distribution of L. monocytogenes in the different plants and products studied. Thirteen dried sausage processing plants were sampled at two different times of the working day.

View Article and Find Full Text PDF

Listeria monocytogenes has been recognized as one of the most important foodborne pathogens dealt with by the food. The bacterium has been found in every part along the pork processing industry from the slaughterhouse to the cutting room and the delicatessen factories. During the fermentation and drying of sausages, L.

View Article and Find Full Text PDF

Total atmospheric deposition, i.e., both wet and dry deposition, was sampled during 11 months in the "Ile-de-France" region, France.

View Article and Find Full Text PDF

The wet, dry and total atmospheric depositions of some metals (Al, Cd, Cr, Cu, Fe, Na, Pb and Zn) were sampled at two sites and atmospheric fallout fluxes were determined for these locations. This work, led by two different research groups, allowed to reach two main goals: to define a simple analytical procedure to secure accurate shipboard sampling and analysis of atmospheric deposition, and to assess anthropogenic impacts of heavy metals to the environment. The first step about the validation step showed that the prevalent deposition type was dry deposition which represents 40, 60 and 80% for Cd, Cu and Pb, respectively.

View Article and Find Full Text PDF

Dredging rivers is needed to ensure safe navigable waters, rivers and waterways. To anticipate the management of dredged materials in the case of the river Seine basin, the quality of the sediments in the river is checked every 3 years before dredging operations. The river Seine Basin is heavily submitted to pollution pressure from nearby industrial activities and urban expansion of Paris and its region.

View Article and Find Full Text PDF

An acetylcholinesterase (AChE) based amperometric bioelectrode for a selective detection of low concentrations of organophosphorus pesticides has been developed. The amperometric needle type bioelectrode consists of a bare cavity in a PTFE isolated Pt-Ir wire, where the AChE was entrapped into a photopolymerised polymer of polyvinyl alcohol bearing styrylpyridinium groups (PVA-SbQ). Cyclic voltammetry, performed at Pt and AChE/Pt disk electrodes, confirmed the irreversible, monoelectronic thiocholine oxidation process and showed that a working potential of +0.

View Article and Find Full Text PDF

In rivers, sediments are frequently accumulating persistent chemicals, especially for those that are more contaminated as a consequence of pressure related to environmental pollution and human activity. The Seine river basin (France) is heavily polluted from nearby industrial activities, and the urban expansion of Paris and its suburbs within the Ile de France region and the sediments present in the Seine river basin are contaminated. To ensure safe, navigable waters, rivers and waterways must be dredged.

View Article and Find Full Text PDF

Aliphatic hydrocarbons were assessed in runoff and waste waters from an urban catchment located in Paris. Runoff were sampled from different types of urban surfaces (11 roofs representing four different covering materials, two courtyards and six streets). Waste water samples were collected at the catchment outlet during dry and wet weather periods as well.

View Article and Find Full Text PDF

Two Divisions of the International Union of Pure and Applied Chemistry (IUPAC), namely Physical Chemistry (Commission 1.7 on Biophysical Chemistry formerly Steering Committee on Biophysical Chemistry) and Analytical Chemistry (Commission V.5 on Electroanalytical Chemistry) have prepared recommendations on the definition, classification and nomenclature related to electrochemical biosensors: these recommendations could, in the future, be extended to other types of biosensors.

View Article and Find Full Text PDF

Urban surface contamination, by atmospheric deposits as well as human activities, is a major concern for urban pollution management. Besides coarse street deposits which are clearly perceived and easily removed, suspended solid (SS) surface loads and contamination by heavy metals and hydrocarbons are rarely assessed although they could be of major importance with regards to combined or separate server overflow (CSO and SSO) impacts. Both dry and wet vacuum sampling procedures have been first compared, in the laboratory, using dry and sieved clay or street deposits.

View Article and Find Full Text PDF

Of small species capable of reaching a platinum working electrode from biological samples, calcium cations have been found to inhibit significantly glucose biosensor responses. The sensitivities to glucose of sensors immersed in carbonate buffer saline solutions decreased when 0.5 mM calcium chloride was added.

View Article and Find Full Text PDF

The development of an electrochemically based implantable sensor for glucose is described. The sensor is needle-shaped, about the size of a 28-gauge needle. It is flexible and must be implanted subcutaneously by using a 21-gauge catheter, which is then removed.

View Article and Find Full Text PDF