Once regarded as a rare complication, the potentially fatal bone cement implantation syndrome (BCIS) has been increasingly reported. BCIS can present as transient desaturation, hypotension, cardiac dysrhythmias, and cardiovascular collapse. Diagnosis of BCIS is often clinical and confirmed with computed tomography (CT) imaging postoperatively.
View Article and Find Full Text PDFCoronavirus disease (COVID-19) was declared a pandemic by the World Health Organization on 11 March 2020 because of its rapid worldwide spread. In the operating room, as part of hospital outbreak response measures, anesthesiologists are required to have heightened precautions and tailor anesthetic practices to individual patients. In particular, by minimizing the many aerosol-generating procedures performed during general anesthesia, anesthesiologists can reduce exposure to patients' respiratory secretions and the risk of perioperative viral transmission to healthcare workers and other patients.
View Article and Find Full Text PDFSince the first use of the flexible fibreoptic bronchoscope, a plethora of new airway equipment has become available. It is essential for clinicians to understand the role and limitations of the available equipment to make appropriate choices. The recent 4th National Audit Project conducted in the United Kingdom found that poor judgement with inappropriate choice of equipment was a contributory factor in airway morbidity and mortality.
View Article and Find Full Text PDFBackground And Aims: Fibre-optic intubation (FOI) through supraglottic airway devices (SADs) is useful in the management of the difficult airway. We compared two methods of FOI through seven SADs in a randomised crossover manikin study to assess each device's performance and discuss implications on SAD selection.
Methods: Thirty anaesthetsiologists, 15 seniors and 15 juniors, each performed low skill FOI (LSFOI) with seven SADs using both 'direct' and 'indirect' methods.
Background: The Bonfils Intubation Fibrescope (Bonfils) and the McCoy laryngoscope (McCoy) are airway devices designed to assist tracheal intubation in difficult cases. Individually, both the Bonfils and McCoy have demonstrated superiority to the Macintosh laryngoscope in a simulated difficult airway. In this study, we compared the Bonfils with the McCoy laryngoscope in patients whose tracheal intubation had been intentionally hindered.
View Article and Find Full Text PDFThe Bonfils Retromolar Intubation Fiberscope is a rigid, straight fiberoptic device with a 40-degree curved tip, which facilitates targeted intubation. Bonfils, using a retromolar approach to intubate tracheas of children with Pierre Robin syndrome, was first described in 1983. After an initial steep learning curve, the Bonfils becomes a useful device in the management of normal and difficult airways.
View Article and Find Full Text PDF