Purpose: To investigate the possibility of reducing the injected activity for whole-body [18F]FDG-PET/CT studies of paediatric oncology patients and to assess the usefulness of time-of-flight (TOF) acquisition on PET image quality at reduced count levels.

Procedures: Twenty-nine paediatric oncology patients (12F/17M, 3-18 years old (median age 13y), weight 45±20 kg, BMI 19±4 kg/m), who underwent routine whole-body PET/CT examinations on a Siemens Biograph mCT TrueV system with TOF capability (555ps) were included in this study. The mean injected activity was 156 ± 45 MBq (3.

View Article and Find Full Text PDF

Objective:: The aim of this study is to report a local diagnostic reference level (DRL) for paediatric whole-body (WB) fludeoxyglucose (F-FDG) positron emission tomography (PET) CT examinations.

Methods:: The Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) national DRL (NDRL) age category (0-4 years and 5-14 years), the International Commission on Radiological Protection age category (ICRP age) (<1, >1-5, >5-10, and >10-15 years), and European guideline weight category ( EG weight) (<5, 5-<15, 15-<30, 30-<50, and 50-<80 kg) were used to determine a local DRL for WB F FDG PET/CT studies. Two-structured questionnaires were designed to collect dose data, patient demographics, equipment details, and acquisition protocols for WB F-FDG PET/CT procedures.