Publications by authors named "Thadi Mohan"

Hybrid bioprinting uses sequential printing of melt-extruded biodegradable thermoplastic polymer and cell-encapsulated bioink in a predesigned manner using high- and low-temperature print heads for the fabrication of robust three-dimensional (3D) biological constructs. However, the high-temperature print head and melt-extruded polymer cause irreversible thermal damage to the bioprinted cells, and it affects viability and functionality of 3D bioprinted biological constructs. Thus, there is an urgent need to develop innovative approaches to protect the bioprinted cells, coming into contact or at close proximities to the melt-extruded thermoplastic polymer and the high-temperature print head during hybrid bioprinting.

View Article and Find Full Text PDF

Background: Lateral UKA is a technically more challenging procedure than medial UKA accounting for < 1% of all knee arthroplasties. Robotic UKA for lateral compartment arthritis is rare and has not been reported in India.

Materials And Methods: This is a prospective single-centre clinical study of six patients (five females and one male) who underwent robotic-arm-assisted lateral UKA (RALUKA) between May 2018 and January 2020 with patient-specific 3D-CT preoperative plan.

View Article and Find Full Text PDF

Aim: The objective of the study is to compare the accuracy of implant positioning and limb alignment achieved in robotic-arm assisted total knee arthroplasty(RATKA) and manual total knee arthroplasty(MTKA) to their respective preoperative plan.

Patients And Methods: This was a prospective observational study conducted in a tertiary care centre between August 2018 and January 2020. 143 consecutive RATKA(105 patients) and 151 consecutive MTKA(111 patients) performed by two experienced arthroplasty surgeons were included.

View Article and Find Full Text PDF

Background: Our study aims to determine the planned accuracy of the tibial component placement in robotic arm assisted unicompartmental knee arthroplasty (UKA) versus the conventional jig based UKA of the initial cases done in India for the first time with this particular robotic system.Materials & Methods: Study group 1 consisted of patients who underwent robotic arm (MAKO, Stryker, USA) assisted UKA. Group 2 consists of patients who underwent a standard conventional jig based (Oxford knee, Biomet, UK).

View Article and Find Full Text PDF

Background: Haemophilia is characterized by a partial or complete deficiency of clotting factor VIII or IX. The repeated bleeding episodes into the joints contributes to subsequent chronic arthropathy which debilitates the patient and affects the quality of life. There are lot of hurdles in successful management of such patients.

View Article and Find Full Text PDF

Background: No scientific evidence exists regarding the amount of bone cement used and discarded in primary cemented Total knee arthroplasty (TKA). The aim of this study was to identify the exact amount of bone cement utilized for component fixation in primary TKA.

Methods: In a prospective study carried out at five centers, 133 primary cemented TKAs were performed.

View Article and Find Full Text PDF

Background: Incorrect positioning of the implant and improper alignment of the limb following total knee arthroplasty (TKA) can lead to rapid implant wear, loosening, and suboptimal function. Studies suggest that alignment errors of > 3° are associated with rapid failure and less satisfactory function. Computer navigated systems have been developed to enhance precision in instrumentation during surgery.

View Article and Find Full Text PDF