Publications by authors named "Terry Shirey"

Background: Interference studies of four glucose meters (Nova Biomedical [Waltham, MA] StatStrip [hospital grade], Roche Diagnostics [Indianapolis, IN] Accu-Chek Aviva [home grade], Abbott Diabetes Care [Alameda, CA] Precision FreeStyle Freedom [home grade], and LifeScan [Milpitas, CA] SureStep Flexx [hospital grade]) were evaluated and compared to the clinical laboratory plasma hexokinase reference method (Roche Hitachi 912 chemistry analyzer). These meters were chosen to reflect the continuum of care from hospital to home grade meters commonly seen in North America.

Methods: Within-run precision was determined using a freshly prepared whole blood sample spiked with concentrated glucose to give three glucose concentrations.

View Article and Find Full Text PDF

Objectives: Glucose meters are widely used in self and hospital monitoring of blood glucose. We examined the analytical performance of a StatStrip glucose monitoring system.

Design And Methods: Linearity, % recovery and within-run imprecision were studied using glucose-spiked whole blood.

View Article and Find Full Text PDF

Dysnatremia may cause life-threatening encephalopathy in marathon runners. Hypernatremia and exercise-associated hyponatremia (EAH) may manifest with mental status changes and, if untreated, progress to coma and death. We reviewed the on-site blood sodium testing and treatment in collapsed runners at the finish-line medical tent at the Boston marathons from 2001 through 2008.

View Article and Find Full Text PDF

We measured analytes in collapsed Boston Marathon runners to compare with changes in asymptomatic runners. Of collapsed runners at the 2007 marathon, 18.2% had a measurable cardiac troponin T (cTnT) value with a mean postrace level of 0.

View Article and Find Full Text PDF

Background: Most glucose meter comparisons to date have focused on performance specifications likely to impact subcutaneous dosing of insulin. We evaluated four hospital-based glucose meter technologies for accuracy, precision, and analytical interferences likely to be encountered in critically ill patients, with the goal of identifying and discriminating glucose meter performance specifications likely to impact intensive intravenous insulin dosing.

Methods: Precision, both within-run and day-to-day, was evaluated on all four glucose meters.

View Article and Find Full Text PDF

Purpose: Exercise-associated hyponatremia (EAH), as defined by a blood sodium concentration [Na+] less than 135 mmol/L, may lead to hypotonic encephalopathy with fatal cerebral edema. Understanding the pathogenetic role of antidiuresis may lead to improved strategies for prevention and treatment.

Methods: Normonatremic marathon runners were tested pre- and post-race for creatine kinase, interleukin-6, cortisol, prolactin, and arginine vasopressin.

View Article and Find Full Text PDF

Context: Recommendations for prevention and treatment of medical emergencies in participants in marathon races center on maintenance of adequate hydration status and administration of fluids. Recently, new recommendations for fluid replacement for marathon runners were promulgated by medical and athletic societies. These new guidelines encourage runners to drink ad libitum between 400 and 800 mL/h as opposed to the previous "as much as possible" advice.

View Article and Find Full Text PDF