Purpose: To identify areas of consensus among experts on the performance of endothelial keratoplasty by using a modified Delphi approach, to help create a framework for novice surgeons to adopt these procedures.
Methods: Thirty-one international experts in endothelial keratoplasty participated. Two rounds of electronic survey were followed by a hybrid, virtual meeting.
Drowning is the third leading cause of death from unintentional injury worldwide, accounting for 7% of all injury-related deaths. The World Health Organization estimates that there are ≈236 000 deaths due to drowning worldwide each year. Significant efforts have focused on creating systems to prevent drowning, but an average of 4000 fatal and 8000 nonfatal drownings still occur annually in the United States-likely an underestimate.
View Article and Find Full Text PDFBackground: Incorporating emerging knowledge into Emergency Medical Service (EMS) competency assessments is critical to reflect current evidence-based out-of-hospital care. However, a standardized approach is needed to incorporate new evidence into EMS competency assessments because of the rapid pace of knowledge generation.
Objective: The objective was to develop a framework to evaluate and integrate new source material into EMS competency assessments.
Purpose: We aimed to compare the rate of 6-month endothelial cell loss (ECL) and 6-month graft survival in eyes that did not require a postoperative rebubble with eyes that did require a postoperative rebubble after Descemet membrane endothelial keratoplasty (DMEK) surgery.
Methods: A consecutive series of DMEK surgeries performed from September 2013 to March 2020 was retrospectively analyzed. Eyes that did not require a rebubble for graft detachment were compared with eyes with 1 rebubble and eyes with 2 or more rebubbles for 6-month ECL and graft survival.
Purpose: The purpose of this study was to determine whether controlled balanced salt solution (BSS) bursts during graft preparation can safely promote formation of a double-scrolled Descemet membrane endothelial keratoplasty (DMEK) graft in younger donor tissue.
Methods: DMEK grafts prepared from young donor tissue (average age, 55 years; range, 39-66 years) were floated in BSS to spontaneously form scrolls (N = 10 pairs). Controlled BSS bursts were used to promote double-scroll (DS) formation in 1 member of each pair.
Objective: Continued competency is poorly defined in emergency medical services (EMS), with no established method for verifying continued competency at a national level. The objective of this project was to refine understanding of continued competency for EMS clinicians in the U.S.
View Article and Find Full Text PDFThis article aims to provide guidance to health care workers for the provision of basic and advanced life support to children and neonates with suspected or confirmed coronavirus disease 2019 (COVID-19). It aligns with the 2020 American Heart Association Guidelines for Cardiopulmonary Resuscitation (CPR) and Emergency Cardiovascular care while providing strategies for reducing risk of transmission of severe acute respiratory syndrome coronavirus 2 to health care providers. Patients with suspected or confirmed COVID-19 and cardiac arrest should receive chest compressions and defibrillation, when indicated, as soon as possible.
View Article and Find Full Text PDFPurpose: The aim of this study was to determine whether loading a Descemet membrane endothelial keratoplasty (DMEK) graft using a drop-in procedure results in more endothelial cell loss (ECL) than the standard suction procedure.
Methods: Pairs of donor corneas with equivalent preprocessing endothelium were prepared using the standard protocol of our eye bank. One member of each pair was loaded into an injector using the standard suction protocol.
Purpose: To determine whether using younger donor tissue for Descemet membrane endothelial keratoplasty (DMEK) surgery influences clinical outcomes.
Methods: Scroll tightness, unscrolling time, rebubble rate, and preoperative and 3- and 6-month postoperative endothelial cell density (ECD) and endothelial cell loss (ECL) were compared for 661 DMEK grafts prepared from younger (aged younger than 50 yrs, n = 81) and older donors (aged 50 yrs or older, n = 580) with Student t test, χ2 test, or Mann-Whitney U test.
Results: There was no difference in overall unscrolling time (younger donors: 3.
The purpose is to determine if the preoperative central endothelial cell density (ECD) in triple (phacoemulsification plus intraocular lens implantation plus DSAEK) and non-triple Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) procedures have a relationship with the 5-year postoperative ECD or percent Endothelial Cell Loss (ECL).Out of 986 consecutive DSAEK surgeries for Fuchs dystrophy, 241 eyes had 5-year ECD measurements available. Endothelial cell densities were then evaluated against preoperative ECDs to obtain measures of ECL.
View Article and Find Full Text PDFCulturing all donor rims for fungus makes no sense. Only 1% of all cultures will be positive, and of those positive cultures, only 6% will also have a clinical infection. Prophylactically treating all positive cultures means 94% of patients will be treated unnecessarily.
View Article and Find Full Text PDFPurpose: To determine whether specific donor characteristics influence postoperative rebubble rate and 6-month endothelial cell loss (ECL) in Descemet membrane endothelial keratoplasty (DMEK).
Methods: A retrospective analysis of a consecutive series of 857 DMEK surgeries using eye bank-prepared donor tissue was performed between September 2013 and April 2018. DMEK graft characteristics including donor age, preoperative endothelial cell density (ECD), preservation time, death-to-preservation time, and donor diabetes status were analyzed for correlation with rebubble rate and 6-month postoperative ECL.
Purpose: The purpose of this study was to compare the clinical outcomes from using eye bank-prepared, endothelium-out preloaded Descemet membrane endothelial keratoplasty (DMEK) tissue with those obtained with endothelium-out surgeon-loaded DMEK tissue using the same surgical technique at 1 site.
Methods: This study retrospectively reviewed 400 consecutive cases of DMEK from March 2016 to April 2018. The last 200 cases using surgeon-loaded tissue were compared with the first 200 cases using preloaded tissue.
Purpose: To describe Descemet membrane endothelial keratoplasty (DMEK) cases complicated by spontaneous intraoperative fibrin formation.
Methods: DMEK surgeries performed at two centers using a standardized technique were reviewed retrospectively for the occurrence of intraoperative fibrin formation. Cases were assessed for recipient medical history, donor age, best spectacle-corrected visual acuity (BSCVA), intraoperative unscrolling time, 6-month endothelial cell loss (ECL), and the course of the mate donor cornea.
Purpose: To determine the relationship between anterior chamber depth (ACD) and percent endothelial cell loss (ECL) after Descemet Stripping Automated Endothelial Keratoplasty (DSAEK).
Method: In 78 eyes receiving triple procedure (DSAEK combined with cataract extraction and posterior chamber intraocular lens (PCIOL) implantation), ACD was measured preoperatively with an intraocular lens (IOL) Master and ECL was calculated with specular microscopy at 6 months, 1, 2, 3, and 4 years postoperatively. ACD and ECL from all 78 eyes were compared using correlation analysis and students t test.
Purpose: To determine the concentration of amphotericin B that would be both effective against Candida albicans contamination and safe for corneal endothelial cells (CECs) in cold storage conditions.
Methods: Triplicate media cultures were inoculated with 10 colony-forming units (CFUs)/mL of C. albicans (American Type Culture Collection 10231), supplemented with amphotericin B (0-20 μg/mL), stored in cold conditions (2°C-8°C) for 72 hours, and analyzed quantitatively for CFUs.
Cornea
September 2019
Purpose: To identify donor and recipient factors, including eye bank tissue observations, predictive of operative complications in the Cornea Preservation Time Study.
Methods: One thousand three hundred thirty study eyes undergoing Descemet stripping automated endothelial keratoplasty for Fuchs dystrophy or pseudophakic/aphakic corneal edema were randomized to receive a donor cornea with preservation time (PT) of 0 to 7 days (N = 675) or 8 to 14 days (N = 655). Donor factors included demographics, prelamellar corneal and postlamellar lenticule dissection thickness, central endothelial cell density, and tissue processing time.
With the success of Descemet's stripping automated endothelial keratoplasty (DSAEK) technique providing better outcomes in visual prognosis and theoretically lower rejection rate than penetrating keratoplasty, DSAEK dominated the realm of endothelial keratoplasty for the past decade. However, Descemet's membrane endothelial keratoplasty (DMEK) has become more and more popular worldwide due to its even lower rejection rate, faster visual recovery, better visual outcome, and lower long-term endothelial loss. In this article, we demonstrate the techniques and nuances of DMEK surgery in detail for corneal specialists who are beginning their DMEK surgeries.
View Article and Find Full Text PDF