Vascular catheterization is becoming a popular technique in laboratory rodents, facilitating repetitive blood sampling and infusion in individual animals. In mice, catheterization is complicated by their small body size, which may increase the risk of postoperative complications that may both threaten catheter longevity and animal welfare. Less obvious complications to a permanent catheter may include subclinical infection, visceral tissue damage from disseminating microthrombi released from the catheter, and distress from being isolated from conspecifics and other experimental stressors.
View Article and Find Full Text PDFWe compared 6 frequently used mouse blood-sampling methods (lateral tail incision; tail-tip amputation; sublingual, submandibular, and saphenous vein puncture; and retrobulbar sinus puncture during isoflurane anesthesia) with regard to induction of local and systemic inflammation, stomach contents, weight changes, and corticosterone levels at 6 h to 12 d after sampling. Local inflammation was assessed through histopathology and assessment of the expression of inflammation and tissue damage-related genes (, , , , , and ) in sampled tissue. Systemic inflammation was assessed through quantification of plasma haptoglobin levels, measurement of blood expression, and evaluation of histopathologic changes in lung, kidney, liver, and spleen.
View Article and Find Full Text PDFCatheterization of laboratory mice is commonly performed in biomedical research to infuse substances and for blood sampling. One approach is to catheterize the right common carotid artery and advance the catheter until the tip is positioned in the aorta or the proximal brachiocephalic trunk. Owing to the small body size of the mouse, a catheter tends to occupy a great part of even the larger vessel lumens, and this may increase vascular resistance with potential pathophysiological impacts on the heart.
View Article and Find Full Text PDFAutomated blood sampling through a vascular catheter is a frequently utilized technique in laboratory mice. The potential immunological and physiological implications associated with this technique have, however, not been investigated in detail. The present study compared plasma levels of the cytokines IL-1β, IL-2, IL-6, IL-10, IL-17A, GM-CSF, IFN-γ and TNF-α in male NMRI mice that had been subjected to carotid artery catheterization and subsequent automated blood sampling with age-matched control mice.
View Article and Find Full Text PDFBackground: Commercially available ELISA kits are popular among investigators that quantify faecal corticosterone or cortisol metabolites (FCM) for stress assessment in animals. However, in faeces, these assays mainly detect immunoreactive glucocorticoid metabolites. Since different assays contain antibodies of different origin, the detection level and cross-reactivity towards different metabolites and other steroids differ considerably between assays.
View Article and Find Full Text PDFThe physiological stress response is frequently gauged in animals, non-invasively, through measuring glucocorticoids in excreta. A concern with this method is, however, the unknown effect of variations in diets on the measurements. With an energy dense diet, leading to reduced defecation, will low concentrations of glucocorticoids be artificially inflated? Can this effect be overcome by measuring the total output of glucocorticoids in excreta? In a controlled laboratory setting we explored the effect in mice.
View Article and Find Full Text PDFMale BALB/c mice single-housed for a period of three weeks were found to respond with a more marked hypothermia to a challenge with a selective serotonergic agonist (8-OH-DPAT) than their group-housed counterparts. This effect of single housing was verified by screening a genetically heterogeneous population of male mice on a C57BL/6 background from a breeding colony. Enhanced activity of the implicated receptor (5-HT1A) leading to an amplified hypothermic effect is strongly associated with depressive states.
View Article and Find Full Text PDFRetro-bulbar sinus puncture and facial vein phlebotomy are two widely used methods for blood sampling in laboratory mice. However, the animal welfare implications associated with these techniques are currently debated, and the possible physiological and pathological implications of blood sampling using these methods have been sparsely investigated. Therefore, this study was conducted to assess and compare the impacts of blood sampling by retro-bulbar sinus puncture and facial vein phlebotomy.
View Article and Find Full Text PDFVascular catheterization is increasingly carried out in laboratory mice, but the long-term patency of catheters implanted in mice is limited owing to their small size. The authors compared mice that were catheterized in their right common carotid artery either with a silicone catheter with a polyurethane tip or with a 100% polyurethane catheter to determine which catheter type was better suited for long-term studies in mice. The catheters were inspected daily and were flushed if blood was visible in the catheters; if no blood was visible, they were flushed every 3 d.
View Article and Find Full Text PDFOral administration of perioperative analgesia to laboratory mice is beneficial compared with administration by injection. The mice become less stressed when allowed to voluntarily ingest the drug in a palatable feed item and it results in high and long-lasting serum concentrations of the drug. We have previously demonstrated sticky nut and chocolate paste to be well-liked by mice and readily ingested in most cases.
View Article and Find Full Text PDFFacial vein (cheek blood) and caudal vein (tail blood) phlebotomy are two commonly used techniques for obtaining blood samples from laboratory mice, while automated blood sampling through a permanent catheter is a relatively new technique in mice. The present study compared physiological parameters, glucocorticoid dynamics as well as the behavior of mice sampled repeatedly for 24 h by cheek blood, tail blood or automated blood sampling from the carotid artery. Mice subjected to cheek blood sampling lost significantly more body weight, had elevated levels of plasma corticosterone, excreted more fecal corticosterone metabolites, and expressed more anxious behavior than did the mice of the other groups.
View Article and Find Full Text PDFBackground: Studies have reported that heparin may be unsuitable as an anticoagulant in human plasma samples when quantifying cytokines using multiplex bead array assays. For mouse samples, multiplex assays have been validated for serum and EDTA-plasma, but it remains to be elucidated whether heparin influences the quantification of cytokines, and if so - to what extent. Furthermore, laboratory mice are often anesthetized for blood sampling, which causes acute stress that may influence circulating cytokine concentrations and thus bias experimental results.
View Article and Find Full Text PDFThe use of blood corticosterone and faecal corticosterone metabolites as biomarkers of post-surgical stress and pain in laboratory animals has increased during the last decade. However, many aspects of their reliability in laboratory mice remain uninvestigated. This study investigated serum corticosterone and adrenocorticotropic hormone (ACTH) in mice subjected to isoflurane anaesthesia and vasectomy, and mice subjected to isoflurane anaesthesia without surgery.
View Article and Find Full Text PDFBackground/aim: Automated blood sampling has the benefit of sampling without human intervention, thus minimizing the associated stress response. Since this technique has not been thoroughly investigated in mice, the present study was designed to evaluate this technology in mice.
Materials And Methods: Male catheterized BALB/c mice were subjected to automated blood sampling, fecal sampling and daily recording of body weight and food intake for three days post-surgery.
The analysis of glucocorticoids excreted in feces is becoming a widespread technique for determining animal wellbeing in a wide variety of settings. In the present study an extraction protocol and an ELISA assay for quantifying fecal corticosterone metabolites (FCM) in BALB/c and C57bl/6 mice were validated. Lower ratios of solvent (ethanol) to mass of fecal sample were found to be sufficient in extracting FCM compared to what has been reported previously.
View Article and Find Full Text PDFRecognition of pain and stress is a common challenge when working with laboratory mice. The aim of the current study was to identify noninvasive parameters to assess the severity and duration of possible pain and stress after vasectomy in BALB/c mice. Mice underwent isoflurane anesthesia with or without vasectomy.
View Article and Find Full Text PDFThe content of cadmium and selenium in horse kidneys from Jutland , Denmark, in relation to age, local geographical variation and possible relationship between the two elements has been investigated. During the winter of 1982-1983 kidneys from 50 horses were sampled and analysed for cadmium and selenium. The cadmium content of the horse kidneys was recorded in connection with the age of the horses.
View Article and Find Full Text PDF