Background: Improvements of soft tissue to the abutment surface results in more stable peri-implant conditions, however, few human histological studies have compared soft tissue responses around different abutment materials.
Purpose: To describe the peri-implant tissue around 3 abutment materials; titanium, zirconia, and gold alloy, over an 8-week healing period.
Materials And Methods: Fifteen edentulous sites were treated with implants.
According to the study, there were unexpected tiny bone spicules being inspected in peri-implant soft tissue. These displaced autogenous bone chips were probably presented when preparing implant sites. The displaced bone spicules seemed not induced significant inflammatory reactions; on contrary, defects of specimens and dissolving bone spicules pictures were demonstrated.