Publications by authors named "Taylor M Duguay"

Objectives: Computed tomography (CT) myocardial perfusion imaging (CT-MPI) with hyperemia induced by regadenoson was evaluated for the detection of myocardial ischemia, safety, relative radiation exposure, and patient experience compared with single-photon emission computed tomography (SPECT) imaging.

Materials And Methods: Twenty-four patients (66.5 y, 29% male) who had undergone clinically indicated SPECT imaging and provided written informed consent were included in this phase II, IRB-approved, and FDA-approved clinical trial.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to evaluate the utilization of invasive and noninvasive tests and compare cost in patients presenting with chest pain to the emergency department (ED) who underwent either triple-rule-out computed tomography angiography (TRO-CTA) or standard of care.

Materials And Methods: We performed a retrospective single-center analysis of 2156 ED patients who presented with acute chest pain with a negative initial troponin and electrocardiogram for myocardial injury. Patient cohorts matched by patient characteristics who had undergone TRO-CTA as a primary imaging test (n=1139) or standard of care without initial CTA imaging (n=1017) were included in the study.

View Article and Find Full Text PDF

Purpose: This study investigated the impact of gender differences on the diagnostic performance of machine-learning based coronary CT angiography (cCTA)-derived fractional flow reserve (CT-FFR) for the detection of lesion-specific ischemia.

Method: Five centers enrolled 351 patients (73.5% male) with 525 vessels in the MACHINE (Machine leArning Based CT angiograpHy derIved FFR: a Multi-ceNtEr) registry.

View Article and Find Full Text PDF

In this article, the authors discuss the technical background and summarize the current body of literature regarding virtual monoenergetic (VM) images derived from dual-energy CT data, which can be reconstructed between 40 and 200 keV. Substantially improved iodine attenuation at lower kiloelectron volt levels and reduced beam-hardening artifacts at higher kiloelectron volt levels have been demonstrated from all major manufacturers of dual-energy CT units. Improved contrast attenuation with VM imaging at lower kiloelectron volt levels enables better delineation and diagnostic accuracy in the detection of various vascular or oncologic abnormalities.

View Article and Find Full Text PDF

Objectives: This study was conducted to investigate the influence of coronary artery calcium (CAC) score on the diagnostic performance of machine-learning-based coronary computed tomography (CT) angiography (cCTA)-derived fractional flow reserve (CT-FFR).

Background: CT-FFR is used reliably to detect lesion-specific ischemia. Novel CT-FFR algorithms using machine-learning artificial intelligence techniques perform fast and require less complex computational fluid dynamics.

View Article and Find Full Text PDF

Objective: The purpose of this study is to assess the value of an automated model-based plaque characterization tool for the prediction of major adverse cardiac events (MACE).

Methods: We retrospectively included 45 patients with suspected coronary artery disease of which 16 (33%) experienced MACE within 12 months. Commercially available plaque quantification software was used to automatically extract quantitative plaque morphology: lumen area, wall area, stenosis percentage, wall thickness, plaque burden, remodeling ratio, calcified area, lipid rich necrotic core (LRNC) area and matrix area.

View Article and Find Full Text PDF

Objective: The objective of this study was to correlate early recurrence of atrial fibrillation (AF) after ablation with noninvasive imaging using cardiac computed tomography (CT).

Methods: CT image data of 260 patients who had undergone wide area circumferential ablation (WACA) between October 2005 and August 2010 as well as from 30 subjects in sinus rhythm without a history of AF (control group) were retrospectively analyzed. To evaluate early outcome of AF ablation, all AF patients underwent follow-up with a 30-day event monitor 3 to 4 months after ablation.

View Article and Find Full Text PDF

Purpose: To develop institutional diagnostic reference levels (IDRL) for coronary CT angiography (CCTA) according to patient size by analyzing radiation dose changes over the past 10 years.

Materials And Methods: This IRB approved retrospective investigation analyzed radiation dose data from CCTA between 2007 and 2016 at our institution. Annual trends in radiation dose were described for each scanner type and scanning mode.

View Article and Find Full Text PDF

Objectives: We sought to investigate the diagnostic performance of coronary CT angiography (cCTA)-derived plaque markers combined with deep machine learning-based fractional flow reserve (CT-FFR) to identify lesion-specific ischemia using invasive FFR as the reference standard.

Methods: Eighty-four patients (61 ± 10 years, 65% male) who had undergone cCTA followed by invasive FFR were included in this single-center retrospective, IRB-approved, HIPAA-compliant study. Various plaque markers were derived from cCTA using a semi-automatic software prototype and deep machine learning-based CT-FFR.

View Article and Find Full Text PDF

Computed tomographic (CT) coronary artery calcium scoring (CAC) has been validated as a well-established screening method for cardiovascular risk stratification and treatment management that is used in addition to traditional risk factors. The purpose of this review is to present an update on current and future applications of CAC. Areas covered: The topic of CAC is summarized from its introduction to current application with focus on the validation and clinical integration including cardiovascular risk prediction and outcome, cost-effectiveness, impact on downstream medical testing, and the technical advances in scanner and software technology that are shaping the future of CAC.

View Article and Find Full Text PDF

Purpose To compare two technical approaches for determination of coronary computed tomography (CT) angiography-derived fractional flow reserve (FFR)-FFR derived from coronary CT angiography based on computational fluid dynamics (hereafter, FFR) and FFR derived from coronary CT angiography based on machine learning algorithm (hereafter, FFR)-against coronary CT angiography and quantitative coronary angiography (QCA). Materials and Methods A total of 85 patients (mean age, 62 years ± 11 [standard deviation]; 62% men) who had undergone coronary CT angiography followed by invasive FFR were included in this single-center retrospective study. FFR values were derived on-site from coronary CT angiography data sets by using both FFR and FFR.

View Article and Find Full Text PDF

Purpose: To investigate the effect of an iterative beam-hardening correction algorithm (iBHC) on artifact reduction and image quality in coronary CT angiography (cCTA) with low tube voltage.

Material And Methods: Thirty-six patients (17 male, mean age, 57.3 ± 14.

View Article and Find Full Text PDF

Objectives: To investigate the minimum iodine delivery rate (IDR) required to achieve diagnostic coronary attenuation (300 HU) with dual-energy coronary CTA.

Methods: Acquisitions were performed on a circulation phantom with a third- generation dual-source CT scanner. Contrast media was injected for a fixed time whilst IDRs varied from 1.

View Article and Find Full Text PDF

Objectives: To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition.

Methods: 78 patients (58% male, 61.5±9.

View Article and Find Full Text PDF

This study investigated the performance of coronary computed tomography angiography (cCTA) with cCTA-derived fractional flow reserve (CT-FFR) compared with invasive coronary angiography (ICA) with fractional flow reserve (FFR) for therapeutic decision making in patients with suspected coronary artery disease (CAD). Seventy-four patients (62 ± 11 years, 62% men) with at least 1 coronary stenosis of ≥50% on clinically indicated dual-source cCTA, who had subsequently undergone ICA with FFR measurement, were retrospectively evaluated. CT-FFR values were computed using an on-site machine-learning algorithm to assess the functional significance of CAD.

View Article and Find Full Text PDF

Objectives: To investigate the progression of coronary atherosclerosis burden by coronary CT angiography (CCTA) and to demonstrate its association with the incidence of major adverse cardiac events (MACE).

Methods: We retrospectively studied patients with stable angina who had undergone repeat CCTA due to recurrent or worsening symptoms. Lipid-rich, fibrous, calcified and total plaque burden as well as coronary diameter stenosis were quantitatively analysed.

View Article and Find Full Text PDF

Invasive coronary angiography (ICA) with measurement of fractional flow reserve (FFR) by means of a pressure wire technique is the established reference standard for the functional assessment of coronary artery disease (CAD) ( 1 , 2 ). Coronary computed tomographic (CT) angiography has emerged as a noninvasive method for direct assessment of CAD and plaque characterization with high diagnostic accuracy compared with ICA ( 3 , 4 ). However, the solely anatomic assessment provided with both coronary CT angiography and ICA has poor discriminatory power for ischemia-inducing lesions.

View Article and Find Full Text PDF

This study investigated the prognostic value of coronary computed tomography angiography (cCTA)-derived fractional flow reserve (CT-FFR) in patients with acute coronary syndrome (ACS) and multivessel disease to gauge significance and guide management of non-culprit lesions. We retrospectively analyzed data of 48 patients (56 ± 10 years, 60% men) who were admitted for symptoms suggestive of ACS and underwent dual-source cCTA followed by invasive coronary angiography with culprit lesion intervention. Culprit lesions were retrospectively identified on cCTA using images obtained during invasive coronary angiography.

View Article and Find Full Text PDF

Coronary computed tomographic angiography (CCTA) has evolved as a rapid and highly sensitive method for the exclusion of obstructive coronary artery disease. Unfortunately, as it pertains to moderate and severe lesions, the ability to discriminate between those that are hemodynamically significant and those that are nonobstructive is lacking. Consequently, this deficiency can result in a significant number of unnecessary referrals for invasive angiography that yields nonobstructive results.

View Article and Find Full Text PDF

Recent studies demonstrated that sinogram affirmed iterative reconstructions (SAFIRE) can produce higher-resolution images with greater robustness for the reduction of various imaging artefacts. Eighty-five patients were prospectively evaluated and underwent a high-pitch spiral acquisition CT scan. In-stent noise, signal-to-noise ratio(SNR), stent-lumen attenuation increase ratio (SAIR), and subjective image quality score were measured and compared between the SAFIRE and Filter back projection (FBP) reconstructions.

View Article and Find Full Text PDF

Objective: We investigated the impact of iterative beam-hardening correction (IBHC) with advanced modeled iterative reconstruction (ADMIRE) of ultra-low radiation-dose tin filtered (Sn100 kVp) CACS acquisitions on image quality, calcium quantification, and risk classification.

Methods: CT data of 60 patients (55% male, age 62.3 ± 9.

View Article and Find Full Text PDF

Purpose To assess the accuracy of computed tomographic (CT) angiography for diagnosis of cerebral aneurysms 5 mm or smaller, with digital subtraction angiography (DSA) as the reference standard, in a large patient cohort Materials and Methods This retrospective study was approved by the local institutional review board with a waiver of written informed consent. A total of 1366 patients who underwent cerebral CT angiography followed by DSA were included. The performance of CT angiography for depiction of aneurysms was evaluated by two readers on a per-patient and per-aneurysm basis and based on size of aneurysm, location, and status of rupture.

View Article and Find Full Text PDF

Objectives: To investigate the diagnostic accuracy of CT coronary artery calcium scoring (CACS) with tin pre-filtration (Sn100kVp) using iterative beam-hardening correction (IBHC) calcium material reconstruction compared to the standard 120kVp acquisition.

Background: Third generation dual-source CT (DSCT) CACS with Sn100kVp acquisition allows significant dose reduction. However, the Sn100kVp spectrum is harder with lower contrast compared to 120kVp, resulting in lower calcium score values.

View Article and Find Full Text PDF

Purpose: To evaluate the relationship between fractional flow reserve (FFR)-determined coronary artery stenosis severity and myocardial perfusion parameters derived from dynamic myocardial CT perfusion imaging (CTP) in an ex-vivo porcine heart model.

Methods: Six porcine hearts were perfused according to Langendorff. Circulatory parameters such as arterial blood flow (ABF) (L/min), mean arterial pressure (MAP) (mmHg) and heart rate (bpm) were monitored.

View Article and Find Full Text PDF

Objectives: This study sought to evaluate the image quality and diagnostic accuracy of noncontrast quiescent-interval single-shot (QISS) magnetic resonance angiography (MRA) versus iodine-contrast computed tomography angiography (CTA) in patients with peripheral artery disease (PAD), with invasive digital subtraction angiography (DSA) as the reference standard.

Background: QISS is a recently introduced noncontrast MRA technique. Although the diagnostic accuracy of QISS is reportedly similar to that of contrast-enhanced MRA, its performance compared with contrast-enhanced CTA, the most frequently used noninvasive modality for evaluation of PAD, is unknown.

View Article and Find Full Text PDF