Publications by authors named "Tayfun Ozdemir"

In this study, different prosthetic designs that could be applied instead of advanced surgical techniques in atrophic maxilla were evaluated with finite element analysis. Atrophic posterior maxilla was modeled using computer tomography images and four models were prepared as follows: Model 1 (M1), two implants supporting a three-unit distal cantilever prosthesis; Model 2 (M2), two implants supporting a three-unit conventional fixed partial denture; Model 3 (M3), three implants supporting three connected crowns; and Model 4 (M4), two implants supporting two connected crowns. Implants 4 mm in width and 8 mm or 13 mm in length were used.

View Article and Find Full Text PDF

Limbus vertebra is a condition characterized by marginal interosseous herniation of the nucleus pulposus, and causes non specific symptoms like low back pain, back pain, muscle spasms and radiculopathy. It is frequently confused with vertebral fracture, infection, schmorl nodule or tumour because it has not a spesific symptom. It usually causes mechanical low back pain rather than inflammatory low back pain.

View Article and Find Full Text PDF

It is important to develop functional transmucosal implant surfaces that reduce the number of initially adhering bacteria and they need to be modified to improve the anti-bacterial performance. Commercially pure Ti sheets were anodized in an electrolyte containing ethylene glycol, distilled water and ammonium fluoride at room temperature to produce TiO2 nanotubes. These structures were then annealed at 450°C to transform them to anatase.

View Article and Find Full Text PDF

Background: It has been reported in many articles that marginal bone resorptions are prevented by platform-switching design. However, what occurs when these implants are placed in the apical position is not completely known.

Purpose: This report describes a randomized controlled clinical trial study that aims to test the hypothesis that less resorption will occur when platform-switching implants are placed 1 mm below bone level.

View Article and Find Full Text PDF

The present study assesses histopathologically and histomorphometrically the effects of light-emitting diode (LED) photobiomodulation therapy (LPT) on bone healing in BioOss-filled femoral defects of rats. It has been reported that LPT modulates cellular metabolic processes, leading to an enhanced regenerative potential for biological tissues. Thirty-six male Wistar rats with femoral bone defects were divided into 4 groups: defect group (empty bone defect, without application of LPT), graft group (bone defect filled with BioOss, without application of LPT), (defect+LPT) group (empty bone defect, with application of LPT), and (graft+LPT) group (bone defect filled with BioOss, with application of LPT).

View Article and Find Full Text PDF

The purpose of this study was to compare the efficacy between the use of bovine bone graft material and platelet-rich fibrin (PRF) mixture (test group) and bovine bone graft material and collagen membrane combination (control group) in 2-stage maxillary sinus augmentation. According to specific inclusion/exclusion criteria, patients treated between 2008 and 2012 were selected. Panoramic radiographs were used for radiologic assessments.

View Article and Find Full Text PDF

Purpose: Simultaneous insertion of multiple implants may exhibit suboptimal positions, especially in edentulous jaws considered for a fixed restoration. The aim of this study was to compare the incidence of and confounding factors in implant positioning errors related to the use of freehand and computer-aided treatment methods.

Materials And Methods: A total of 353 implants were placed in 54 patients with at least one edentulous jaw using freehand and computer-aided methods involving 16 mucosa- and 12 bone-supported single- and multiple-type stereolithographic surgical guides.

View Article and Find Full Text PDF

Aim: To assess the efficacy of quick-release lornoxicam (LNX) on patient-reported acute pain after dental implant surgery.

Materials And Methods: The study included subjects in good general health, aged 18 to 65 and scheduled to receive a maximum of three implants in the same quadrant. Participants received either 8 mg LNX or placebo and were asked to use the medications in case of pain in the first 120 min after implant surgery.

View Article and Find Full Text PDF

Purpose: The relationship of conventional multi-slice computed tomography (CT)- and cone beam CT (CBCT)-based gray density values and the primary stability parameters of implants that were placed by stereolithographic surgical guides were analyzed in this study.

Materials And Methods: Eighteen edentulous jaws were randomly scanned by a CT (CT group) or a CBCT scanner (CBCT group) and radiographic gray density was measured from the planned implants. A total of 108 implants were placed, and primary stability parameters were measured by insertion torque value (ITV) and resonance frequency analysis (RFA).

View Article and Find Full Text PDF

Purpose: Deviations of implants that were placed by conventional computed tomography (CT)- or cone beam CT (CBCT)-derived mucosa-supported stereolithographic (SLA) surgical guides were analyzed in this study.

Materials And Methods: Eleven patients were randomly scanned by a multi-slice CT (CT group) or a CBCT scanner (CBCT group). A total of 108 implants were planned on the software and placed using SLA guides.

View Article and Find Full Text PDF

Objectives: The aims of this study were to investigate the incidence of bacteremia, bacteriology and antibiotic susceptibility against to causative bacteria associated with dental implant installation.

Study Design: 30 generally healthy patients were enrolled in this study. Blood samples were collected at baseline and at 30 minutes after dental implant installation and 24 hours after dental implant surgery.

View Article and Find Full Text PDF

Objectives: The aim of this study was to compare the surgical and post-operative outcomes of a computer-aided implant surgery performed by bone- and mucosa-supported stereolithographic (SLA) guides against the standard technique.

Material And Methods: Multiple- and single-type SLA guides from two commercial manufacturers were produced and a total of 341 implants were placed to 52 patients using the standard technique (Control group), bone- (bone-supported guide [BSG] group) and mucosa-supported SLA guides (Flapless group) in 21, 16 and 15 patients, respectively. Surgical duration (min), number of analgesics (tablets) as well as hemorrhage, difficulty in mouth opening (or trismus) and other incidences were recorded.

View Article and Find Full Text PDF

Objectives: Narrow diameter implants (NDIs; diameter >3.75 mm) are useful in replacement of missing incisor teeth and when the bucco-lingual width of the edentulous crest is insufficient. The present study evaluated the success and survival rates, peri-implant parameters, mechanical and prosthetic post-loading complications of NDIs followed over a 10-year period.

View Article and Find Full Text PDF

Background: Stereolithographic surgical guides provide significant benefits during the simultaneous placement of multiple implants with regard to the final prosthetic plan. However, deviation from the planning poses a significant risk. Deviations of implants that were placed by bone-, tooth-, and mucosa-supported stereolithographic surgical guides were examined in this study.

View Article and Find Full Text PDF

Purpose: Peri-implant dehiscence defects occur frequently after dental implant placement. Various graft materials and techniques are proposed for treatment. In this study, an injectable calcium phosphate cement (Augmentech, Wetzlar, Germany) applied to a peri-implant defect was investigated.

View Article and Find Full Text PDF

Background: The analgesic and anti-inflammatory efficacy of tenoxicam and meloxicam were evaluated in this double-masked, randomized, prospective study by analyzing pain scores and the need for rescue-analgesic agents following dental implant surgery.

Methods: One hundred patients, in whom 241 dental implants were placed, were divided into two groups. For 4 days beginning the day before surgery, the first group received meloxicam, 15 mg daily, and the second group received tenoxicam, 20 mg daily, followed by 1 hour preoperatively and for 2 days thereafter.

View Article and Find Full Text PDF

Background: The aim of the present study was to compare the peri-implant soft tissue health status of implants supporting overdentures with bar attachments or ball attachments in the mandible, as well as patient satisfaction with these attachment types.

Methods: The study included a Dolder bar group with 18 cases (43 implants) and a ball attachment group with 18 cases (51 implants). The mean function period in the Dolder bar group was 49 months (range: 12 to 72 months) and in the ball attachment group, the mean was 23 months (range: 12 to 40 months).

View Article and Find Full Text PDF