Publications by authors named "Tausif Monif"

Background: A novel and accurate high-throughput tandem mass spectroscopic method has been developed and validated for determination of imatinib, a inhibitor against chronic myeloid leukemia.

Materials & Methods: Chromatographic separation was carried on XTerra RP18 column (150 mm × 4.6 mm, 5 µm particle size) manufactured by Waters Corporation, MA, USA.

View Article and Find Full Text PDF

A liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous determination of simvastatin (SV) and simvastatin acid (SVA) in human plasma. To improve assay sensitivity and achieve simultaneous analysis, SVA monitored in (-)ESI (electrospray ionization) mode within the first 4.5 min and SV thereafter in (+)ESI mode.

View Article and Find Full Text PDF

Purpose: This study was designed to characterize the pharmacokinetic profile and to assess bioequivalence of the sponsor's test formulation (imatinib mesylate 400 mg tablets) with an innovator product (Gleevec 400 mg tablets, Novartis Pharmaceuticals) under fed conditions, in adult patients of Philadelphia chromosome positive chronic myeloid leukemia (Ph+ CML) stabilized on imatinib mesylate 400 mg. In addition, the aim of this study was to monitor the safety profile of investigational medicinal products (IMPs).

Materials And Methods: A multicenter, randomized, open label, two-period, crossover, single dose bioequivalence study was designed for conduct under fed conditions in 42 adult Ph+ CML patients already stabilized on imatinib 400 mg tablets.

View Article and Find Full Text PDF

We established a sensitive, selective, and rapid analytical method for the quantitation and pharmacokinetic investigation of mycophenolate mofetil in human plasma. To our knowledge, this is the first method that characterizes presence of mycophenolate mofetil glucuronide in clinical samples through tandem mass spectrometry detection and resolves mycophenolate mofetil from its glucuronide metabolite. Liquid chromatography coupled to tandem mass spectrometry detection in positive ion mode was selected to provide optimal selectivity and sensitivity.

View Article and Find Full Text PDF

An analytical method based on solid phase extraction was developed and validated for analysis of adefovir in human plasma. Adefovir-d was used as an internal standard and Synergi MAX RP80A (150 mm×4.6 mm, 4 µm) column provided the desired chromatographic separation of compounds followed by detection with mass spectrometry.

View Article and Find Full Text PDF

A reliable, simple, and robust liquid chromatography-tandem mass spectro-metric (LC-MS/MS) method has been developed and validated that employs solid-phase extraction for the simultaneous estimation of amlodipine and valsartan in human K3EDTA plasma using amlodipine-d4 and valsartan-d9 as internal standards. Chromatographic separation of amlodipine and valsartan was achieved on the Luna C18 (2)100A (150 × 4.6 mm, 5 μm) column using acetonitrile: 5 mM ammonium formate solution (80:20, v/v) as the mobile phase at a flow rate of 0.

View Article and Find Full Text PDF

A sensitive, accurate and selective liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for the simultaneous quantitation of atorvastatin (AT) and its equipotent hydroxyl metabolites, 2-hydroxy atorvastatin (2-AT) and 4-hydroxy atorvastatin (4-AT), in human plasma. Electrospray ionization (ESI) interface in negative ion mode was selected to improve the selectivity and the sensitivity required for this application. Additionally, a solid phase extraction (SPE) step was performed to reduce any ion-suppression and/or enhancement effects.

View Article and Find Full Text PDF

Objectives: To demonstrate the bioequivalence between the test and reference formulations of losartan/hydrochlorothiazide 50 + 12.5 mg tablet and evaluate the effect of ethnicity on pharmacokinetics properties of losartan, losartan carboxylic acid and hydrochlorothiazide on healthy Asian Indian and Japanese volunteers.

Methods: Randomized, open-label, crossover, bioavailability studies were conducted separately in healthy Asian Indian and Japanese volunteers.

View Article and Find Full Text PDF

A pharmacokinetic bioequivalence study was conducted in Asian subjects, to compare a fixed dose combination capsule single oral dose of alpha adrenoceptor blocker-Alfuzosin hydrochloride 10mg extended release and muscarinic antagonists-Solifenacin succinate 5mg against individually administered Xatral XL 10mg tablets (Alfuzosin) of Sanofi Synthelabo Limited, United Kingdom (UK) and Vesicare 5mg tablets (Solifenacin) of Astellas Pharma Limited, UK under fed conditions. Blood samples were collected pre-dose up to 72 h post dose for determination of plasma Alfuzosin and Solifenacin concentrations and calculation of the pharmacokinetic parameters. ANOVA was performed on the log (natural)-transformed pharmacokinetic parameters.

View Article and Find Full Text PDF

Introduction: Oxycodone is a semisynthetic opioid agonist used for the relief of moderate to severe pain. A new generic oxycodone hydrochloride (HCl) extended release (ER) tablet is currently being developed by Ranbaxy Pharmaceutical Inc., New Brunswick, NJ, USA.

View Article and Find Full Text PDF

In this study a rapid, simple and sensitive assay to quantify clozapine in human plasma by using reverse phase high performance liquid chromatographic method has been developed. Clozapine was extracted from human plasma using a mixture of chloroform: n-hexane 50:50 employing liquid-liquid extraction method. The calibration curve was found to be linear in the concentration range of 25-800 ng/ml.

View Article and Find Full Text PDF

A reliable, selective and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of lamotrigine in human plasma using lamotrigine-C3, d3 as an internal standard. Analyte and internal standard were extracted from human plasma by solid-phase extraction and detected in positive ion mode by tandem mass spectrometry with electrospray ionization (ESI) interface. Chromatographic separation was performed on a Chromolith SpeedROD; RP-18e column (50-4.

View Article and Find Full Text PDF

A sensitive, accurate and highly stereoselective assay for the simultaneous determination of venlafaxine (VEN) and its equipotent metabolite, O-desmethyl venlafaxine (ODV), in human plasma was developed and validated. Analytes were simultaneously extracted from plasma using solid-phase extraction and detected by tandem mass spectrometry in positive ion mode with a turbo ion spray interface. Deuterium-labeled VEN and ODV were used as internal standards.

View Article and Find Full Text PDF

Metaxalone is a skeletal muscle relaxant, an approved drug for pain relief. Published bioanalytical methods lacked detailed stability evaluation in blood and plasma. An accurate, precise, high-throughput tandem mass spectroscopic method has been developed and validated.

View Article and Find Full Text PDF

A bioanalytical method was developed and validated to estimate donepezil, 6-desmethyl donepezil and 5-desmethyl donepezil simultaneously in human plasma using galantamine as an internal standard (IS). The chromatographic separation was achieved on a reverse-phase XTerra RP (150 × 4.6 mm, 5 µm) column without affecting recovery (mean recovery > 60% with CV < 10%) for all analytes.

View Article and Find Full Text PDF

A bioequivalence study for venlafaxine generic formulation was conducted as an open label, balanced, randomized, two-way crossover, single-dose study. In this study, a comparison of various pharmacokinetic parameters of venlafaxine hydrochloride 150 mg modified release capsules of Ranbaxy and EFEXOR®-XR 150 mg capsules of Wyeth, in healthy, adult, male, human subjects under fasting condition was performed to conclude bioequivalence. Venlafaxine and its major active metabolite O-desmethylvenlafaxine (ODV) are racemates.

View Article and Find Full Text PDF

Background: Type 2 diabetes mellitus is associated with a 2- to 4-fold increased risk of coronary heart disease (CHD). Combined therapy with an antihyperglycaemic agent and an HMG-CoA reductase inhibitor (statin) is indicated for the treatment of diabetic patients at risk of CHD. Patients with type 2 diabetes are generally considered to be at equivalent cardiovascular disease risk to patients with established CHD, and should have low-density lipoprotein (LDL) cholesterol levels reduced to <100 mg/dL or by 30-40%.

View Article and Find Full Text PDF

Objectives: The aim of this work was to develop a simple, sensitive and selective LC/MS/MS method for the assay of valganciclovir and ganciclovir in human plasma.

Design And Methods: Sample preparation involved solid phase extraction on mix mode cation exchanger. Separation was performed on Chromolith RP18e column using water, trifluoroacetic acid (1M, pH 4.

View Article and Find Full Text PDF

Plasma estimation of valaciclovir, an antiviral drug, is challenging due to both in-vivo and ex-vivo hydrolysis to active metabolite acyclovir. A simultaneous method is described involving the solid-phase ion-exchange extraction procedure requiring 100 μL of plasma volume, a reverse-phase Lichrosphere RP Select B (125 × 6 mm, 5 μm) column and isocratic mobile phase to achieve the desired chromatographic separation. ESI-MS/MS multiple reaction monitoring in positive polarity, detected mass pairs for valaciclovir (m/z 325.

View Article and Find Full Text PDF

Background: To evaluate the venlafaxine:O-desmethyl venlafaxine (active metabolite) in vivo formation ratio (MR) in three independent bioequivalence (BE) studies consisting of single-dosed (under fasted and fed conditions) and multiple-dosed clinical trials on healthy subjects. The pooled data pharmacokinetic (PK) analysis demonstrates a model to conduct enantiomer/racemate/active metabolite bioanalysis for regulatory submission of bioavailability/bioequivalence (BA/BE) studies using an interesting MR concept.

Results: BE was established for all three studies.

View Article and Find Full Text PDF

Terbinafine, a widely used antifungal drug, is a challenging molecule for quantitative bioanalysis due to certain factors contributing assay variability. Despite previous attempts at human plasma determination of terbinafine, exhaustive stability of the drug or an internal standard was lacking. Internal standard stability with negligible variation throughout the analysis is an indicator of a reliable bioanalytical method as the majority of LC-MS/MS assays are based on analyte/IS response ratios for quantitation.

View Article and Find Full Text PDF

LC- ESI- MS/MS simultaneous bioanalytical method was developed to determine acitretin and its metabolite isoacitretin in human plasma using acitretin-d3 used as the internal standard for both analytes. The compounds were extracted using protein precipitation coupled with liquid-liquid extraction with flash freezing technique. Negative mass transitions (m/z) of acitretin, isoacitretin and acitretin-d3 were detected in multiple reactions monitoring (MRM) mode at 325.

View Article and Find Full Text PDF

Background: Valsartan is a selective angiotensin II type 1 receptor blocker indicated for the treatment of hypertension. Although the bioavailability and pharmacokinetic properties of valsartan have been well characterized, a literature search did not identify any reports concerning the bioavailability of valsartan in the Indian population.

Objective: This study was undertaken to compare the pharmacokinetic properties of 2 branded generic valsartan formulations (tests A and B) with a branded innovator product (reference) in healthy Indian male subjects.

View Article and Find Full Text PDF

Objective: To assess the comparative bioavailability of two formulations (250 mg/5 mL suspension) of cefuroxime axetil (CAS 64544-07-6), administered with food, in healthy volunteers of both sexes.

Methods: The study was conducted using an open, randomized, two-period crossover design with a 1-week washout interval. Plasma samples were obtained for up to 12 h post dose.

View Article and Find Full Text PDF

A rapid, selective and sensitive high performance liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for the determination and pharmacokinetic investigation of cefuroxime in human plasma. Cefuroxime and the internal standard (IS), cefoxitin, were extracted from plasma samples using solid phase extraction with Oasis HLB cartridges. Chromatographic separation was performed on a LiChrospher 60 RP Select B column (125 mm x 4 mm i.

View Article and Find Full Text PDF