Publications by authors named "Taulu S"

Wearable magnetoencephalography based on optically pumped magnetometers (OPM-MEG) offers non-invasive and high-fidelity measurement of human brain electrophysiology. The flexibility of OPM-MEG also means it can be deployed in participants of all ages and permits scanning during movement. However, the magnetic fields generated by neuronal currents - which form the basis of the OPM-MEG signal - are much smaller than environmental fields, and this means measurements are highly sensitive to interference.

View Article and Find Full Text PDF

Education sculpts specialized neural circuits for skills like reading that are critical to success in modern society but were not anticipated by the selective pressures of evolution. Does the emergence of brain regions that selectively process novel visual stimuli like words occur at the expense of cortical representations of other stimuli like faces and objects? "Neuronal Recycling" predicts that learning to read should enhance the response to words in ventral occipitotemporal cortex (VOTC) and decrease the response to other visual categories such as faces and objects. To test this hypothesis, and more broadly to understand the changes that are induced by the early stages of literacy instruction, we conducted a randomized controlled trial with pre-school children (five years of age).

View Article and Find Full Text PDF

In face-to-face interactions with infants, human adults exhibit a species-specific communicative signal. Adults present a distinctive "social ensemble": they use infant-directed speech (parentese), respond contingently to infants' actions and vocalizations, and react positively through mutual eye-gaze and smiling. Studies suggest that this social ensemble is essential for initial language learning.

View Article and Find Full Text PDF

Magnetoencephalography (MEG) recordings are often contaminated by interference that can exceed the amplitude of physiological brain activity by several orders of magnitude. Furthermore, the activity of interference sources may spatially extend (known as source leakage) into the activity of brain signals of interest, resulting in source estimation inaccuracies. This problem is particularly apparent when using MEG to interrogate the effects of brain stimulation on large-scale cortical networks.

View Article and Find Full Text PDF

Optically pumped magnetometers (OPMs) are emerging as a near-room-temperature alternative to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). In contrast to SQUIDs, OPMs can be placed in a close proximity to subject's scalp potentially increasing the signal-to-noise ratio and spatial resolution of MEG. However, experimental demonstrations of these suggested benefits are still scarce.

View Article and Find Full Text PDF

The signal space separation (SSS) method is routinely employed in the analysis of multichannel magnetic field recordings (such as magnetoencephalography (MEG) data). In the SSS method, signal vectors are posed as a multipole expansion of the magnetic field, allowing contributions from sources internal and external to a sensor array to be separated via computation of the pseudo-inverse of a matrix of the basis vectors. Although powerful, the standard implementation of the SSS method on MEG systems based on optically pumped magnetometers (OPMs) is unstable due to the approximate parity of the required number of dimensions of the SSS basis and the number of channels in the data.

View Article and Find Full Text PDF

In magnetoencephalography, linear minimum norm inverse methods are commonly employed when a solution with minimal a priori assumptions is desirable. These methods typically produce spatially extended inverse solutions, even when the generating source is focal. Various reasons have been proposed for this effect, including intrisic properties of the minimum norm solution, effects of regularization, noise, and limitations of the sensor array.

View Article and Find Full Text PDF

Our objective is to formulate the problem of the magnetoencephalographic (MEG) sensor array design as a well-posed engineering problem of accurately measuring the neuronal magnetic fields. This is in contrast to the traditional approach that formulates the sensor array design problem in terms of neurobiological interpretability the sensor array measurements.We use the vector spherical harmonics (VSH) formalism to define a figure-of-merit for an MEG sensor array.

View Article and Find Full Text PDF

Methylmercury pollution is a global problem, and Minamata disease (MD) is a stark reminder that exposure to methylmercury can cause irreversible neurological damage. A "glove and stocking type" sensory disturbance due to injured primary sensory cortex (SI) (central somatosensory disturbance) is the most common neurologic sign in MD. As this sign is also prevalent in those with polyneuropathy, we aimed to develop an objective assessment for detecting central somatosensory disturbances in cases of chronic MD.

View Article and Find Full Text PDF

We aim to investigate the effects of head model inaccuracies on signal and source reconstruction accuracies for various sensor array distances to the head. This allows for the assessment of the importance of head modeling for next-generation magnetoencephalography (MEG) sensors, optically-pumped magnetometers (OPM).A 1-shell boundary element method (BEM) spherical head model with 642 vertices of radius 9 cm and conductivity of 0.

View Article and Find Full Text PDF

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions.

View Article and Find Full Text PDF

The excellent temporal resolution and advanced spatial resolution of magnetoencephalography (MEG) makes it an excellent tool to study the neural dynamics underlying cognitive processes in the developing brain. Nonetheless, a number of challenges exist when using MEG to image infant populations. There is a persistent belief that collecting MEG data with infants presents a number of limitations and challenges that are difficult to overcome.

View Article and Find Full Text PDF

We discuss specific challenges and solutions in infant MEG, which is one of the most technically challenging areas of MEG studies. Our results can be generalized to a variety of challenging scenarios for MEG data acquisition, including clinical settings. We cover a wide range of steps in pre-processing, including movement compensation, suppression of magnetic interference from sources inside and outside the magnetically shielded room, suppression of specific physiological artifact components such as cardiac artifacts.

View Article and Find Full Text PDF

Research on children and adults with developmental dyslexia-a specific difficulty in learning to read and spell-suggests that phonological deficits in dyslexia are linked to basic auditory deficits in temporal sampling. However, it remains undetermined whether such deficits are already present in infancy, especially during the sensitive period when the auditory system specializes in native phoneme perception. Because dyslexia is strongly hereditary, it is possible to examine infants for early predictors of the condition before detectable symptoms emerge.

View Article and Find Full Text PDF

Optically pumped magnetometers (OPMs) developed for magnetoencephalography (MEG) typically operate in the spin-exchange-relaxation-free (SERF) regime and measure a magnetic field component perpendicular to the propagation axis of the optical-pumping photons. The most common type of OPM for MEG employs alkali atoms, e.g.

View Article and Find Full Text PDF

Developmental dyslexia, a specific difficulty in learning to read and spell, has a strong hereditary component, which makes it possible to examine infants for early predictors of the condition even prior to the emergence of detectable symptoms. Using magnetoencephalography (MEG), we found smaller and shorter neural responses to simple sounds in infants at risk for dyslexia at 6 as compared to 12 months of age, a pattern that was reversed in age-matched controls. The findings indicate atypical auditory processing in at-risk infants across the sensitive period for native-language phoneme learning.

View Article and Find Full Text PDF

Word learning is a significant milestone in language acquisition. The second year of life marks a period of dramatic advances in infants' expressive and receptive word-processing abilities. Studies show that in adulthood, language processing is left-hemisphere dominant.

View Article and Find Full Text PDF

Objective: Magnetoencephalography (MEG) signals typically reflect a mixture of neuromagnetic fields, subject-related artifacts, external interference and sensor noise. Even inside a magnetically shielded room, external interference can be significantly stronger than brain signals. Methods such as signal-space projection (SSP) and signal-space separation (SSS) have been developed to suppress this residual interference, but their performance might not be sufficient in cases of strong interference or when the sources of interference change over time.

View Article and Find Full Text PDF

Objective: Electromagnetic recordings are useful for non-invasive measurement of human brain activity. They typically sample electric potentials on the scalp or the magnetic field outside the head using electroencephalography (EEG) or magnetoencephalography (MEG), respectively. EEG and MEG are not, however, symmetric counterparts: EEG samples a scalar field via a line integral over the electric field between two points, while MEG samples projections of a vector-valued field by small sensors.

View Article and Find Full Text PDF

Background: Magnetoencephalography (MEG) is an excellent non-invasive tool to study the brain. However, measurements often suffer from the contribution of external interference, including noise from the sensors. Suppression of noise from the data is critical for an accurate representation of brain signals.

View Article and Find Full Text PDF

How the human brain uses self-generated auditory information during speech production is rather unsettled. Current theories of language production consider a feedback monitoring system that monitors the auditory consequences of speech output and an internal monitoring system, which makes predictions about the auditory consequences of speech before its production. To gain novel insights into underlying neural processes, we investigated the coupling between neuromagnetic activity and the temporal envelope of the heard speech sounds (i.

View Article and Find Full Text PDF

A non-invasive functional-brain-imaging system based on optically-pumped-magnetometers (OPM) is presented. The OPM-based magnetoencephalography (MEG) system features 20 OPM channels conforming to the subject's scalp. We have conducted two MEG experiments on three subjects: assessment of somatosensory evoked magnetic field (SEF) and auditory evoked magnetic field (AEF) using our OPM-based MEG system and a commercial MEG system based on superconducting quantum interference devices (SQUIDs).

View Article and Find Full Text PDF

Cognitive neuroscience questions are commonly tested with experiments that involve a cohort of subjects. The cohort can consist of a handful of subjects for small studies to hundreds or thousands of subjects in open datasets. While there exist various online resources to get started with the analysis of magnetoencephalography (MEG) or electroencephalography (EEG) data, such educational materials are usually restricted to the analysis of a single subject.

View Article and Find Full Text PDF

Advanced Parkinson's disease (PD) is characterized by an excessive oscillatory beta band activity in the subthalamic nucleus (STN). Deep brain stimulation (DBS) of STN alleviates motor symptoms in PD and suppresses the STN beta band activity. The effect of DBS on cortical sensorimotor activity is more ambiguous; both increases and decreases of beta band activity have been reported.

View Article and Find Full Text PDF