Publications by authors named "Tatiana Trejos"

Coulson et al. [1] proposed methodology for the estimation of the P and S terms used in glass interpretation when assessing the value of the findings given activity level propositions. These terms arise in a model proposed by Evett [2], Evett and Buckleton [3], and are based on survey data.

View Article and Find Full Text PDF

Several organizations have outlined the need for standardized methods for conducting physical fit comparisons. This study answers this call by developing and evaluating a systematic and transparent approach for examining, documenting, and interpreting textile physical fits, using qualitative feature descriptors and a quantitative metric (Edge Similarity Score, ESS) for the physical fit examination of textile materials. Here, the results from 1027 textile physical fit comparisons are reported.

View Article and Find Full Text PDF

A physical fit is an important observation that can result from the forensic analysis of trace evidence as it conveys a high degree of association between two items. However, physical fit examinations can be time-consuming, and potential bias from analysts may affect judgment. To overcome these shortcomings, a data analysis algorithm using mutual information and a decision tree has been developed to support practitioners in interpreting the evidence.

View Article and Find Full Text PDF

This paper describes the construction and use of a machine-learning model to provide objective support for a physical fit examination of duct tapes. We present the ForensicFit package that can preprocess and database raw tape images. Using the processed tape image, we trained a convolutional neural network to compare tape edges and predict membership scores (i.

View Article and Find Full Text PDF

This study reports the use of direct analysis in real time-mass spectrometry (DART-MS) for the detection of organic gunshot residues (OGSR) in a variety of matrices of interest for forensics, customs, and homeland security. Detection limits ranged from (0.075 to 12) ng, with intra- and inter-day reproducibility below 0.

View Article and Find Full Text PDF

This study assists the interpretation of glass and paint evidence by filling an existing gap in the background occurrence that reflects the socioeconomic and demographic circumstances in the United States. The collection was performed in a college US city (Morgantown, West Virginia) to determine the effect of the type of clothing worn at different seasons on the presence of glass and paint. Tape lifts and sole scrapings (1038) were collected from 210 participants and up to six clothing and footwear areas per individual.

View Article and Find Full Text PDF

This study expands upon a previously developed method that quantifies the similarity of the compared tape edges by systematically studying the effect of several separation methods and tape grades on the quality of a fit. Analysts examined more than 3300 pairs of hand-torn or scissor-cut duct tapes from three different tape grades while they were kept blind from the ground truth to minimize bias. The samples were examined following a three-step methodology: 1) qualitative assessment of the overall edge alignment and description of edge pattern, 2) macroscopic evaluation of the edges' features, 3) bin by bin subunit assessment of tape edges and estimation of the edge similarity score.

View Article and Find Full Text PDF

In this study, glass from 30 different portable electronic devices (PED) screens, 15 screen protectors (SP), and 3 brands of liquid glass (LG) were analyzed using a µ-XRF instrument equipped with two silicon drift detectors (SDD). Additional analysis of six fragments, all originating from the same PED and SP screen, assessed the elemental homogeneity within a single glass source. Examinations of the 30 PEDs and the majority of the SP screens revealed spectra with low sodium and high potassium, which is likely due to the ion exchange process at the surface during the glass manufacturing process.

View Article and Find Full Text PDF

This study describes the use of single particle inductively coupled plasma time-of-flight mass spectrometry (spICP-TOFMS) for the detection and classification of inorganic gunshot residue (IGSR) particles. To establish reliable multi-element criteria to classify IGSR particles, leaded and lead-free IGSR reference materials were analyzed, and the elemental compositions of the individual particles were quantified. The results suggest that expanded element compositions may be used to classify IGSR particles via spICP-TOFMS compared to those used in conventional IGSR analysis using scanning electron microscopy energy dispersive X-ray spectroscopy (SEM-EDS).

View Article and Find Full Text PDF

Analysis of gunshot residue currently lacks effective screening methods that can be implemented in real time at the crime scene. Historically, SEM-EDS has been the standard for analysis; however, advances in technology have brought portable instrumentation to the forefront of forensic science disciplines, including the screening of GSR. This study proposes electrochemical methods with disposable screen-printed carbon electrodes for GSR screening at the laboratory and points of care due to their rapid, cost-efficient, and compact platform.

View Article and Find Full Text PDF

Consensus concentration values for seventeen (17) major and trace elements typically present in soda-lime glass manufactured using the "float " process and used in the quantitative analysis and forensic comparison of glass samples were determined using laser ablation (LA) micro sampling coupled to inductively coupled plasma mass spectrometry (ICP-MS). This is the first reporting of the chemical characterization of a new set of float glass intended for use as matrix-matched calibration standards in the forensic analysis and comparison of glass by LA-ICP-MS using a standard test method (ASTM E2927-16e1). Three Corning Float Glass Standards (CFGS) were manufactured at low, medium, and high concentrations of 32 elements typically encountered in float glass samples as found in forensic casework.

View Article and Find Full Text PDF

Seventeen laboratories participated in three interlaboratory exercises to assess the performance of refractive index, micro X-ray Fluorescence Spectroscopy (μXRF), and Laser Induced Breakdown Spectroscopy (LIBS) data for the forensic comparison of glass samples. Glass fragments from automotive windshields were distributed to the participating labs as blind samples and participants were asked to compare the glass samples (known vs. questioned) and report their findings as they would in casework.

View Article and Find Full Text PDF

This study reports novel approaches for the detection of gunshot residues (GSR) from the hands of individuals using Laser-Induced Breakdown Spectroscopy (LIBS) and Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS). The methods' performance was evaluated using 159 GSR standard and authentic samples. Forty specimens generated from characterized microparticles were used as matrix-matched primer gunshot residue (pGSR) standards to examine the elemental profiles of leaded and lead-free residues, compared to SEM-EDS and solution-ICP-MS.

View Article and Find Full Text PDF
Article Synopsis
  • Gunshot residue (GSR) consists of both organic (OGSR) and inorganic species (IGSR), but previous methods primarily focused on identifying only IGSR particles.
  • This study proposes a new method using LC-MS/MS to detect both OGSR and IGSR in the same sample, improving detection confidence by reducing potential contamination from non-firearm sources.
  • The technique shows enhanced accuracy and efficiency, allowing analysis of both types of residues in under 20 minutes and expanding the range of detectable analytes compared to other existing methods.
View Article and Find Full Text PDF

The forensic analysis of inorganic gunshot residues (IGSR) involves analytical measurements from samples taken from skin and other substrates. The standard practice for IGSR analysis recommends the use of Scanning Electron Microscopy-Energy Dispersive X-Ray Spectroscopy (SEM-EDS) to identify the gunshot residues using combined information of the particle's morphology and elemental composition. However, the current deficit on IGSR standard reference materials (SRM) limits the optimization of SEM-EDS for modern, lead-free ammunition and the development of emerging analytical techniques.

View Article and Find Full Text PDF

This review paper covers the forensic-relevant literature in paint and glass evidence from 2016 to 2019 as a part of the 19th Interpol International Forensic Science Managers Symposium. The review papers are also available at the Interpol website at: https://www.interpol.

View Article and Find Full Text PDF

The increasing demand for rapid methods to identify both inorganic and organic gunshot residues (IGSR and OGSR) makes electrochemical methods, an attractive screening tool to modernize current practice. Our research group has previously demonstrated that electrochemical screening of GSR samples delivers a simple, inexpensive, and sensitive analytical solution that is capable of detecting IGSR and OGSR in less than 10 min per sample. In this study, we expand our previous work by increasing the number of GSR markers and applying machine learning classifiers to the interpretation of a larger population data set.

View Article and Find Full Text PDF

Physical fit examinations have long played a critical role in forensic science, particularly in the trace evidence, toolmark, and questioned documents disciplines. Specifically, in trace evidence, physical fits arise in various instances such as separated pieces of duct tape, torn textile fragments, and fractured polymeric items to name a few. The case report and research basis for forensic physical fit dates to the late 1700s and varies by material type.

View Article and Find Full Text PDF

Duct tape is a common type material found at crime scenes such as sexual assaults, murders, kidnappings, and bombings. During the examination of a known and questioned item, a 3D realignment along their edges is known as a physical fit and is often regarded as conclusive evidence that the items were once part of a single object. The conclusion of a fit between edges relies on the examiner's judgment to identify distinctive features across the tape ends.

View Article and Find Full Text PDF

This study applies Raman microspectroscopy to differentiate the chemical components in printing inks of different brands, colors, and type using the 532 nm and 785 nm excitation wavelengths. Spectra were collected from 319 inks (78 inkjet, 76 toner, 79 offset, and 86 intaglio) representing various colors. Comparisons were performed to calculate discrimination capability percentages for each ink type.

View Article and Find Full Text PDF

Improvements in printing technology have exacerbated the problem of document counterfeiting, prompting the need for analytical techniques that better characterize inks for forensic analysis and comparisons. In this study, 319 printing inks (toner, inkjet, offset, and Intaglio) were analyzed directly on the paper substrate using scanning electron microscopy-energy dispersive spectroscopy (SEM-EDS) and Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry (LA-ICP-MS). As anticipated, the high sensitivity of LA-ICP-MS pairwise comparisons resulted in excellent discrimination (average of ~ 99.

View Article and Find Full Text PDF

A searchable printing ink database was designed and validated as a tool to improve the chemical information gathered from the analysis of ink evidence. The database contains 319 samples from printing sources that represent some of the global diversity in toner, inkjet, offset, and intaglio inks. Five analytical methods were used to generate data to populate the searchable database including FTIR, SEM-EDS, LA-ICP-MS, DART-MS, and Py-GC-MS.

View Article and Find Full Text PDF

Elemental analysis of glass was conducted by 16 forensic science laboratories, providing a direct comparison between three analytical methods [micro-x-ray fluorescence spectroscopy (μ-XRF), solution analysis using inductively coupled plasma mass spectrometry (ICP-MS), and laser ablation inductively coupled plasma mass spectrometry]. Interlaboratory studies using glass standard reference materials and other glass samples were designed to (a) evaluate the analytical performance between different laboratories using the same method, (b) evaluate the analytical performance of the different methods, (c) evaluate the capabilities of the methods to correctly associate glass that originated from the same source and to correctly discriminate glass samples that do not share the same source, and (d) standardize the methods of analysis and interpretation of results. Reference materials NIST 612, NIST 1831, FGS 1, and FGS 2 were employed to cross-validate these sensitive techniques and to optimize and standardize the analytical protocols.

View Article and Find Full Text PDF

Glass fragments recovered from crime scenes are usually very small and therefore the amount of sample available to conduct forensic analyses is limited. Elemental analysis using conventional digestion methods consumes at least 2-3mg of glass per replicate. LA-ICP-MS requires 10,000 times less glass consumption per analysis ( approximately 280ng), and therefore the sample remains practically unaltered.

View Article and Find Full Text PDF