A spectrometer built using an external cavity pulsed quantum cascade laser is described. The spectrometer has a tuning range from 10 - 13 µm (1,000 - 769 cm) and is designed to target volatile organic compounds (VOCs) which often exhibit water-free molecular absorption within the region. The spectrometer utilizes a hollow silica waveguide gas cell which has an internal volume of a few millilitres, a fast response time (∼1 s), and is advantageous when only low sample volumes, similar to the cell volume, are available.
View Article and Find Full Text PDFPart quality monitoring and control in wire-based directed energy deposition additive manufacturing (w-DEDAM) processes has been garnering continuous interest from both the academic and industrial sectors. However, maintaining a consistent layer height and ensuring that the wall height aligns closely with the design, as depicted in computer-aided design (CAD) models, pose significant challenges. These challenges arise due to the uncertainties associated with the manufacturing process and the working environment, particularly with extended processing times.
View Article and Find Full Text PDFA pressure sensor specified for aerodynamic applications and based on optical fibre strain sensors mounted on a circular glass fibre reinforced polymer membrane is presented. The use of two fibre optic strain sensing technologies is explored, the novel intrinsic fibre segment interferometry (FSI) approach and fibre Bragg gratings (FBGs), with the use of FSI shown to offer a pressure resolution that is 15 times larger than that achieved using an FBG. A number of design and fabrication issues are considered, including the position of the fibres relative to the neutral axis of the membrane and the influence of the membrane support structure on the thermal and pressure sensitivities of the sensor, with particular regards to pressure and temperature discrimination.
View Article and Find Full Text PDFThe use of polarizing optics for both beam steering and phase measurement applications in displacement measuring interferometer designs is almost universal. Interferometer designs that employ polarizing optics in this manner are particularly sensitive to the effects of unwanted optical cavities that form within the optics due to polarization leakage and back reflections from material interfaces. Modeling techniques commonly employed in the design of such interferometers are poorly suited to the analysis of multiple passes through polarizing optics.
View Article and Find Full Text PDFChemical sensors based on optical absorption require accurate knowledge of the optical pathlength of the sample cell. Integrating spheres offer increased pathlengths compared to single pass cells combined with tolerance to misalignment, making them attractive for use in challenging environments subject to vibration. However, the equivalent optical pathlength can be degraded by dirt and / or condensation on the inner surface of the sphere.
View Article and Find Full Text PDFA novel suite of instrumentation for the characterisation of materials held inside an air-tight tube furnace operated up to 250 °C has been developed. Real-time detection of released gases (volatile organic compounds (VOCs), CO, NO, NO, SO, CO and O) was achieved combining commercial off-the-shelf (COTS) gas sensors and sorbent tubes for further qualitative and semi-quantitative analysis by gas chromatography-mass spectrometry coupled to thermal desorption (TD-GC-MS). The test system was designed to provide a controlled flow (1000 cm min) of hydrocarbon free air through the furnace.
View Article and Find Full Text PDFWe have investigated the release of gases and volatile organic compounds (VOCs) from a carbon fibre reinforced epoxy composite matrix used in aircraft structural components. Analysis was performed at several temperatures both up to and above the recommended operating temperature (121 °C) for the material, to a maximum of 250 °C. Gas chromatography-mass spectrometry (GC-MS) combined with thermal desorption (TD-GC-MS) was used to identify and quantify VOCs, and in parallel real-time gas detection with commercial off-the-shelf (COTS) gas sensors.
View Article and Find Full Text PDFA dual beam optical coherence tomography (OCT) instrument has been developed for flow measurement that offers advantages over microscope derived imaging techniques. It requires only a single optical access port, allows simultaneous imaging of the microfluidic channel, does not require fluorescent seed particles, and can provide a millimetre-deep depth-section velocity profile (as opposed to horizontal-section). The dual beam instrument performs rapid re-sampling of particle positions, allowing measurement of faster flows.
View Article and Find Full Text PDFWe present the development of an external cavity Bragg grating stabilized laser for tunable diode laser spectroscopy (TDLS). Our design uses a planar integrated silica-on-silicon platform incorporating a custom written Bragg grating as the wavelength-selective element of the laser cavity. We have developed a prototype singlemode laser at 1651 nm and performed a detailed characterization of its performance for the purpose of spectroscopic measurement of methane at this wavelength using a 25 cm path-length single-pass cell.
View Article and Find Full Text PDFA novel dual beam Optical Coherence Tomography (OCT) instrument has been developed for high velocity flow measurement, principally in microfluidics applications. The scanned dual beam approach creates a pair of image-frames separated by a small spatiotemporal offset. Metre-per-second flow measurement is achieved by rapid re-imaging by the second beam allowing for particle tracking between each image-frame of the pair.
View Article and Find Full Text PDFConfocal scanning combined with low-coherence interferometry is used to provide remote refractive index and thickness measurements of transparent materials. The influence of lens aberrations in the confocal measurement is assessed through ray-trace modeling of the axial point-spread functions generated using optical configurations comprised of paired aspherics and paired achromats. Off-axis parabolic mirrors are suggested as an alternative to lenses and are shown to exhibit much more symmetric profiles provided the system numerical aperture is not too high.
View Article and Find Full Text PDFThis paper investigates the application of feature tracking algorithms as an alternative data processing method for laser speckle instrumentation. The approach is capable of determining both the speckle pattern translation and rotation and can therefore be used to detect the in-plane rotation and translation of an object simultaneously. A performance assessment of widely used feature detection and matching algorithms from the computer vision field, for both translation and rotation measurements from laser speckle patterns, is presented.
View Article and Find Full Text PDFThe development of reliable, affordable and efficient sensors is a key step in providing tools for efficient monitoring of critical environmental parameters. This review focuses on the use of tapered optical fibres as an environmental sensing platform. Tapered fibres allow access to the evanescent wave of the propagating mode, which can be exploited to facilitate chemical sensing by spectroscopic evaluation of the medium surrounding the optical fibre, by measurement of the refractive index of the medium, or by coupling to other waveguides formed of chemically sensitive materials.
View Article and Find Full Text PDFA new method for the analysis and design of fiber Bragg gratings (FBGs) based on the theory of transmission lines has been developed and verified both theoretically and experimentally. The method is an extension of the coupled-mode theory and utilizes the equivalent transmission lines in order to simulate any type of grating, with an easy and direct implementation. The method provides the ability to analyze the optical devices without using full wave approaches, while also facilitating the incorporation of core materials with a complex or non-linear refractive index, non-uniform distributions of the grating's refractive index, and tilted and phase-shifted gratings.
View Article and Find Full Text PDFThis paper describes a technique for measuring refractive index and thickness of transparent plates using a fibre-optic low-coherence interferometer. The interferometer is used to independently measure quantities related to the phase and group refractive indices, n and n, of the material under investigation. Additionally, the dispersion of the phase index dependent quantity is measured by taking advantage of the range of wavelengths available from a broadband source.
View Article and Find Full Text PDFThe diameter of long-period fiber gratings (LPFGs) fabricated in optical fibers with a low cutoff wavelength was be reduced by hydrofluoric acid etching, enhancing the sensitivity to refractive index by more than a factor of 3, to 2611 nm/refractive index unit in the range from 1.333 to 1.4278.
View Article and Find Full Text PDFA laser diode's junction voltage is a sensitive measure of its temperature and can be used in a thermal control feedback loop. To compensate for the temperature dependence of the laser's internal resistance, we have measured the dynamic resistance, ∂V/∂I, by modulating the injection current and measuring the demodulated voltage. The junction voltage was thus controlled while operating at fixed DC injection current.
View Article and Find Full Text PDFDuct-profiling in test samples up to 25 mm in diameter has been demonstrated using a passive, low-coherence probe head with a depth resolution of 7.8 μm, incorporating an optical-fibre-linked conical mirror addressed by a custom-built array of single-mode fibres. Zemax modelling, and experimental assessment of instrument performance, show that degradation of focus, resulting from astigmatism introduced by the conical mirror, is mitigated by the introduction of a novel lens element.
View Article and Find Full Text PDFA long period grating (LPG) modified with a mesoporous film infused with a calixarene as a functional compound was employed for the detection of individual volatile organic compounds (VOCs) and their mixtures. The mesoporous film consisted of an inorganic part, SiO₂ nanoparticles (NPs), along with an organic moiety of poly(allylamine hydrochloride) polycation PAH, which was finally infused with the functional compound, p-sulphanato calix[4]arene (CA[4]) or p-sulphanato calix[8]arene (CA[8]). The LPG sensor was designed to operate at the phase matching turning point to provide the highest sensitivity.
View Article and Find Full Text PDFThe central wavelengths of the resonance bands are critical aspect of the performance of long period gratings (LPGs) as sensors, particularly for devices designed to operate near the phase matching turning point (PMTP), where the sensitivity to measurements can vary rapidly. Generally, LPGs are characterized by their period, but the amplitude of the amplitude of the index modulation is also an important factor in determining the wavelengths of the resonance bands. Variations in fabrication between LPG sensors can increase or decrease the sensitivity of the LPG to strain, temperature or surrounding refractive index.
View Article and Find Full Text PDFHollow silica waveguides (HSWs) are used to produce long path length, low-volume gas cells, and are demonstrated with quantum cascade laser spectroscopy. Absorption measurements are made using the intrapulse technique, which allows measurements to be made across a single laser pulse. Simultaneous laser light and gas coupling is achieved through the modification of commercially available gas fittings with low dead volume.
View Article and Find Full Text PDFWe present a four beam ratiometric setup for an integrating sphere based gas cell, which can correct for changes in pathlength due to sphere wall contamination. This allows for the gas absorption coefficient to be determined continuously without needing to recalibrate the setup. We demonstrate the technique experimentally, measuring methane gas at 1651nm.
View Article and Find Full Text PDFThe use of a range of optical techniques to monitor the process of fabricating optical fiber tapers is investigated. Thermal imaging was used to optimize the alignment of the optical system; the transmission spectrum of the fiber was monitored to confirm that the tapers had the required optical properties and the strain induced in the fiber during tapering was monitored using in-line optical fiber Bragg gratings. Tapers were fabricated with diameters down to 5 μm and with waist lengths of 20 mm using single-mode SMF-28 fiber.
View Article and Find Full Text PDFWe present the results of a detailed analysis of the noise behavior of two CCD spectrometers in common use, an AvaSpec-3648 CCD UV spectrometer and an Ocean Optics S2000 Vis spectrometer. Light sources used include a deuterium UV/Vis lamp and UV and visible LEDs. Common noise phenomena include source fluctuation noise, photoresponse nonuniformity, dark current noise, fixed pattern noise, and read noise.
View Article and Find Full Text PDFAn optical fibre long period grating (LPG), modified with a coating of silica core gold shell (SiO2:Au) nanoparticles (NPs) deposited using the layer-by-layer method, was employed for the development of a biosensor. The SiO2:Au NPs were electrostatically assembled onto the LPG with the aid of a poly(allylamine hydrochloride) (PAH) polycation layer. The LPG sensor operates at the phase matching turning point to provide the highest sensitivity.
View Article and Find Full Text PDF