Purpose: The causes and frequency of medication errors occurring during information technology downtime were evaluated.
Methods: Individuals from a convenience sample of 78 hospitals who were directly responsible for supporting and maintaining clinical information systems (CISs) and automated dispensing systems (ADSs) were surveyed using an online tool between February 2007 and May 2007 to determine if medication errors were reported during periods of system downtime. The errors were classified using the National Coordinating Council for Medication Error Reporting and Prevention severity scoring index.