Ophthalmic Plast Reconstr Surg
January 2010
Purpose: To present the results of external dacryocystorhinostomy (ext-DCR) for epiphora using strict outcome criteria and provide an accurate baseline and evidence from which to compare the results of endonasal dacryocystorhinostomy.
Methods: Retrospective case notes review of 158 consecutive adult patients who underwent primary ext-DCR. Functional success was assessed according to the patients' symptoms and anatomical success was measured using objective tests of lacrimal system patency: 1) the functional endoscopic dye test and/or endoscopic endonasal inspection of the ostium; 2) syringing of the lacrimal system; and 3) the fluorescein dye retention test.