Background: Precise measurement of the intraosseous corridor within the superior pubic ramus is essential for the accurate percutaneous placement of a retrograde superior ramus screw (SRS). However, conventional manual measurement methods are often subjective, leading to variations in results among observers. Our goal was to develop an automated and dependable method for determining the retrograde SRS corridor.
View Article and Find Full Text PDFObjective: Surgical treatment with internal fixation, specifically percutaneous fixation with three cannulated compression screws (CCSs), is the preferred choice for young and middle-aged patients. The mechanical advantage of the optimal spatial configuration with three screws provides maximum dispersion and cortical support. We suspect that the spatial proportion of the oblique triangle configuration (OTC) in the cross-section of the femoral neck isthmus (FNI) may significantly improve shear and fatigue resistance of the fixed structure, thereby stabilizing the internal fixation system in femoral neck fracture (FNF).
View Article and Find Full Text PDFCase: A 20-year-old man with a Tile C1.2 pelvic fracture was treated with skeletal traction. After 3 months, the patient was unable to stand and walk, and the right lower limb was shortened by 7 cm.
View Article and Find Full Text PDFHepatobiliary Pancreat Dis Int
December 2022
Experiments have demonstrated the regulation of long noncoding RNA (lncRNA) in tuberculosis (TB), and negative pressure treatment has been associated with the alleviation of TB. Here, we investigated the interaction of negative pressure and the lncRNA X-inactive specific transcript (XIST) in modulating Mycobacterium tuberculosis (MTB) infection. Initially, we established an in vitro cell model of MTB infection and an in vivo mouse model of MTB infection, followed by treatment with negative pressure.
View Article and Find Full Text PDFPurpose: This study was to test the hypothesis that intramedullary (IM) nailing fixation of midshaft clavicle fractures could result in better clinical outcomes and lower complications rates than plating fixation.
Methods: PubMed, Embase, and the Cochrane Library database were used to search all English language published randomized controlled trials (RCTs) of midshaft clavicle fractures using plating versus IM nailing. The characteristics of the study participants were collected.
Closed reduction and internal fixation with three cannulated compression screws is a common method for treating femoral neck fractures in young and middle-aged patients. Protocols including the inverted triangle configuration and dispersion of the screws still needed further supports. The purpose of this study was to explore a novel oblique triangle configuration (OTC) of three screws in fixing femoral neck fractures based on the morphology of the femoral neck isthmus (FNI).
View Article and Find Full Text PDFAims: Total hip arthroplasty (THA) in patients with hip-dislocation dysplasia remains challenging. This study aims to evaluate whether these patients may benefit from robotic-assisted techniques.
Methods: We reviewed 135 THAs (108 conventional THAs and 27 robotic-assisted THAs) for Crowe type III or IV from January 2017 to August 2019 in our institution.
Background: The cross-sectional area of three parallel screws might affect the stability of the internal fixation of femoral neck fractures. The screws fixed in the oblique-triangle configuration (OTC) were assumed to have a larger cross-sectional area, but the biomechanical stability has not yet been validated. In this study, finite element analyses were performed to compare the biomechanical properties of the internal fixation fixed by the OTC and the traditional Inverted Equilateral Triangle Configuration (IETC).
View Article and Find Full Text PDFOsteoarticular Tuberculosis (TB) is a challenging issue because of its chronicity and recurrence. Many drug delivery systems (DDSs) have been developed for general chemotherapy. Herein, we take advantage of instant hydrogelation to encapsulate drugs onto implants intraoperatively, optimizing the drug release profile against osteoarticular TB.
View Article and Find Full Text PDFObjectives: To investigate the cross-section shape of the femoral neck isthmus (FNI) in three-dimensional reconstruction model of the femoral neck.
Methods: From December 2009 to December 2012, computed tomography (CT) data of bilateral hip joint from 200 consecutive patients (137 males and 63 females, 69.41 ± 9.
Objective: A3 intertrochanteric fracture is an extremely unstable fracture, which is often treated with intramedullary nail, but the implant failure is common due to the posterior medial fragment cannot be reconstructed. A new medial sustainable nail (MSN-Ⅱ) which can reconstruct the femoral medial support by sustainable screw was introduced in this study. The mechanical effect was verified by biomechanical experiment.
View Article and Find Full Text PDFBackground: The reverse obliquity inter-trochanteric fracture is a distinct fracture pattern that is mechanically different from most inter-trochanteric fractures and the optional treatment of it is still controversial. The purpose of this study was to compare differences in the efficacy of a novel nail (medial support nail [MSN-II]) and proximal femoral nail anti-rotation (PFNA-II) in the treatment of reverse obliquity inter-trochanteric fractures (Arbeitsgemeinschaft fur Osteosynthesfrogen/Orthopedic Trauma Association [AO/OTA] 31-A3.1) using finite-element analysis.
View Article and Find Full Text PDFBackground: The femoral neck torsion angle (FNTA) is an important but often neglected parameter in assessments of the anatomical morphology of the femoral neck, which is often confused with the femoral neck anteversion angle (FNAA) in the current literature. Currently, the measurement methods reported in the literature all adopt the naked eye or two-dimensional (2D) visualization method, and the measurement parameters and details are not clearly defined. The objection of this research was to provide a reliable 3D method for determining the femoral neck axis, to improve the measurement method of the FNTA, and to analyze the anatomical and clinical significance of the results.
View Article and Find Full Text PDFBackground: There is a lack of data concerning the use of robotic devices in more complex total hip arthroplasty (THA) cases, such as hip dysplasia, ankylosing spondylolysis, and post-traumatic arthritis.
Case Presentation: This case study presented three cases in which the Mako robotic device was used to help accurately implement the surgical plan. The operations went smoothly.
Optimal acetabular cup orientation is of substantial importance to good long-term function and low complication rates after total hip arthroplasty (THA). The radiographic anteversion (RA) and inclination (RI) angles of the cup are typically studied due to the practicability, simplicity, and ease of interpretation of their measurements. A great number of methods have been developed to date, most of which have been performed on pelvic or hip anteroposterior radiographs.
View Article and Find Full Text PDFBackground: Lateral locking plate (LLP) fixation has gained popularity for the treatment of proximal humeral fractures (PHFs); however, complications can occur due to loss of the medial cortical buttress from fracture comminution.
Materials And Methods: We designed a novel intramedullary anatomical medial strut with allograft bone (IAMSAB) using MIMICS software to specifically fill the intramedullary canal of the proximal humeral bone. We used finite element analysis to evaluate the biomechanical characteristics of a LLP, LLP-intramedullary fixation system (IFS), LLP-anatomical medial locking plate (AMLP), or the combined application of a LLP and IAMSAB (LLP-IAMSAB) fixation construct in patients with a PHF and an unstable medial column.
Background: Available research about the anatomic patterns of intertrochanteric fractures is lacking, and fracture mapping has not previously been performed on intertrochanteric fractures. This study aimed to determine the major trajectories of intertrochanteric fracture lines using computed tomography data from a series of surgically treated patients.
Methods: In this study, 504 patients with intertrochanteric fractures were retrospectively analyzed.
The use of negative-pressure wound therapy (NPWT) has displayed significant clinical benefits in the healing of infected wounds. However, the effects of NPWT on bacterial colonisation and infection of traumatic wounds has been controversial. The aim of this study is to evaluate the impact of NPWT treatment in rabbits with a contaminated full-thickness wound on bacterial behaviour, including colony morphology, spatial distribution, fissional proliferation, and bacterial bioburden.
View Article and Find Full Text PDF