Objectives: Considering The pivotal role of biochemical testing for the management of diabetes mellitus, we studied the current status of diabetes testing and reporting in three countries of the Asia-Pacific region.
Methods: A survey of 254 practicing pathology laboratories comprising of 40, 11 and 203 laboratories from Sri Lanka, Singapore and the Philippines was conducted under the auspices of the Asia-Pacific Federation for Clinical Biochemistry and Laboratory Medicine (APFCB) Working Group for Diabetes Testing Harmonization using Survey Monkey and Google Forms.
Results: The country response rate varied from 40% to 88%.
Urine albumin concentration and albumin-creatinine ratio are important for the screening of early-stage kidney damage. Commutable urine certified reference materials (CRMs) for albumin and creatinine are necessary for standardization of urine albumin and accurate measurement of albumin-urine ratio. Two urine CRMs for albumin and creatinine with certified values determined using higher-order reference measurement procedures were evaluated for their commutability on five brands/models of clinical analyzers where different reagent kits were used, including Roche Cobas c702, Roche Cobas c311, Siemens Atellica CH, Beckman Coulter AU5800, and Abbott Architect c16000.
View Article and Find Full Text PDFFront Endocrinol (Lausanne)
April 2022
The management of diabetes mellitus in an insulin-dependent patient is challenging in the setting of concomitant antibody-mediated-insulin hypersensitivity. We report a case of a 62-year-old woman with pre-existing type 2 diabetes mellitus of 10 years duration who developed type 3 hypersensitivity reaction to insulin analogue detemir, and subsequently, severe diabetic ketoacidosis (DKA). She was C-peptide negative and was diagnosed with insulin-dependent diabetes.
View Article and Find Full Text PDFBackground: Lipaemic interference on automated analysers has been widely studied using soy-based emulsion such as Intralipid. Due to the greater adoption of fish oil-based lipid emulsion for total parenteral nutrition in view of improved clinical outcomes, we seek to characterize the optical properties of SMOFlipid 20% (Fresenius Kabi, Bad Homburg, Germany), a fish oil-based emulsion, on the Roche Cobas 6000 chemistry analyser (Roche Diagnostic, Basel, Switzerland).
Method: Various amounts of SMOFlipid were spiked into pooled serums.
Introduction And Objectives: Identification of the J-point and measurement of ST segment elevation at the J-point are important for the diagnosis of ST-elevation myocardial infarction (STEMI). We conducted a study to determine the inter-rater reliability (IRR) of J-point location and measurement of the magnitude of ST elevation at the J-point on ECGs of patients with STEMI by emergency department (ED) doctors.
Subjects And Methods: Each participant examined 20 STEMI ECGs during a 1-month period in 2013.