Introduction: To understand the behavior of platelet volume indices and the von Willebrand factor (VWF), in vitro experiments using whole human blood were performed with extracorporeal circulation (ECC) circuits, including membrane oxygenators coated with acrylate copolymer (ACP) or immobilized heparin (IHP).

Methods: Heparinized blood was circulated through two distinct experimental circuits: an ACP-coated reservoir and tubes, as well as membranes coated with either ACP or IHP (comprising five pieces of each type). The platelet distribution width, mean platelet volume (MPV), platelet large cell ratio (P-LCR), VWF quantity (VWFQ), and VWF activity (VWFA) were measured at 0, 8, 16, 24, and 32 h in each experiment.

View Article and Find Full Text PDF

Introduction: The membrane oxygenator in extracorporeal circulation circuits is coated with acrylate-copolymer (ACP) or immobilized heparin (IHP) to enhance hemocompatibility. To evaluate the relative features of both coatings, we compared blood components circulated in the circuits with ACP-and IHP-coated membranes in vitro using whole human blood.

Methods: Whole human blood was heparinized and circulated in two experimental circuits with an ACP-coated reservoir, tubes, and an ACP- or IHP-coated membrane.

View Article and Find Full Text PDF

Introduction: We performed experiments using whole human blood without anticoagulants to clarify the activity of anticoagulant proteins on membranes coated with acrylate-copolymer (ACP) with a hydrophilic blood-contacting layer compared to those coated by immobilizing heparin (IHP) in extracorporeal circulation.

Methods: Whole human blood from healthy volunteers was recirculated in two types of experimental circuits with an ACP-coated reservoir and tubes and an ACP-coated or IHP-coated membrane. To compare the fluctuation of anticoagulant proteins, the circuit pressure at the inlet and outlet of the membrane was measured every 5 min; antithrombin antigen (ATQ), antithrombin activity, protein-C quantitation (PCQ), protein-C activity, protein-S free antigen (PSQ), and protein-S activity were measured at 0, 30, 60, 120, and 180 min in each experiment ( = 5).

View Article and Find Full Text PDF

Introduction: A hemodialysis room has pipes connecting the console and central fluid equipment. While these pipes require disinfection, reports detailing disinfection strategies are unavailable. Therefore, we aimed to compare two easy disinfection strategies differing in sanitization frequency and sanitizer concentration.

View Article and Find Full Text PDF

Objective: Currently, the foreign surfaces of extracorporeal circulation devices are coated with an acrylate-based copolymer that creates a hydrophilic blood-contacting layer to enhance biocompatibility. Several reports of acrylate-based copolymer with respect to biocompatibility have been published; however, the adsorption of peptide compounds on acrylate-based copolymer-coated membranes still requires clarity. In this study, we aimed to understand the adsorption of several peptide compounds of various molecular weights, including albumin, lysozyme, and vancomycin, on acrylate-based copolymer-coated membranes using in vitro studies.

View Article and Find Full Text PDF

Objective:: Extracorporeal circulation devices are coated with a biocompatible polymer coating agent (BPCA) that has a hydrophilic blood-contacting layer, but hemofilters are not. We aimed to investigate the antithrombotic properties of a BPCA-coated hemofilter.

Methods:: Four experiments using BPCA-coated circuits and non-coated hemofilters and four experiments using BPCA-coated circuits and BPCA-coated hemofilters were performed with whole human blood and compared by measuring the circuit pressure every 5 min, antithrombin activity every 40 min, and thrombin-antithrombin complex every 40 min, for a total of 240 min of recirculation.

View Article and Find Full Text PDF