Purpose: Dynamic chest radiography (DCR) is a novel imaging technique used to noninvasively evaluate pulmonary perfusion. However, the standard DCR protocol, which is roughly adapted to the patient's body size, occasionally causes over- or underexposure, which could influence clinical evaluation. Therefore, we proposed a refined protocol by increasing the number of patient body mass index (BMI) categories from three to seven groups and verified its usefulness by comparing the image sensitivity indicators (S-values) and entrance surface doses (ESDs) of the conventional protocol with those of our refined protocol.

View Article and Find Full Text PDF

Rationale And Objectives: Dual-energy subtraction (DES) imaging constitutes a technique that has demonstrated efficacy in enhancing the detectability of pulmonary nodules on chest radiographs. However, a simple and quantitative methodology for evaluating the clinical image quality of DES images is currently lacking. The objective of this study was to investigate the applicability of contrast-detail (C-D) phantom analysis to the visual clinical image quality evaluation of chest DES images.

View Article and Find Full Text PDF

This study aimed to develop an energy-based Hp(3) measurement method using a solid-state detector (SSD). Incident and entrance surface air kerma were measured using an ionization chamber placed free-in-air and in front of an anthropomorphic or slab phantom. Subsequently, three SSDs were placed free-in-air, and half-value layer and readings were obtained.

View Article and Find Full Text PDF

Objectives: This study conducted a receiver operating characteristic (ROC) analysis by applying improved cluster signal-to-noise (CSN) analysis to digital intraoral radiographs and develop an observer-free method of analyzing image quality related to the observer performance in the detection task.

Methods: Two aluminum step phantoms with a thickness interval of 1.0 mm were used for this study.

View Article and Find Full Text PDF

Objectives: This study aimed to quantitatively examine the effect of digital image processing of digital intraoral radiographic images on the resolution characteristics of the output image using a task transfer function (TTF).

Methods: A photostimulable phosphor system with three types of image processing filters, including periodontal, endodontic, and dentine-to-enamel junction filters, was used. Each filter can be used in conjunction with the sharpness filter (+ S).

View Article and Find Full Text PDF

Purpose: Recently developed and commercialized dual-layer flat panel detectors (DL-FPDs) with two indirect scintillators are capable of acquiring dual-energy X-ray images. However, in clinical practice, they are utilized to perform conventional radiography using diagnostic X-rays with a wide energy spectrum. The two layers of the DL-FPD may affect the obtained image quality, even when only using one layer for conventional image acquisition, and these effects are yet to be substantiated.

View Article and Find Full Text PDF

The objective of this study was to investigate the effects of (i) the difference in the beam qualities on the presampled modulation transfer function (MTF) using the edge method and (ii) the readout direction of the edge profile for the photostimulable phosphor (PSP) system. The International Electrotechnical Commission (IEC) defined a technique using the "radiation qualities based on a phantom made up of an aluminum added filter" (RQA). A general radiographic system with a tube voltage of 50 kV and 9.

View Article and Find Full Text PDF

Background: The purpose of the present study was to evaluate the accuracy of the measurements associated with leg alignment on a teleoroentgenogram and an orthoroentgenogram.

Methods: The models being irradiated were manufactured and represented 10° varus and 15° varus leg alignment, in which the true values of hip-knee-ankle angle (HKAA), mechanical axis (MA) length, and percentage of MA (%MA) were already known. HKAA, MA length, and %MA were measured in various radiographic conditions of the teleoroentgenogram and orthoroentgenogram.

View Article and Find Full Text PDF

This study aims to quantitatively evaluate the effect of additional copper-filters (Cu-filters) on the radiation dose and contrast-to-noise ratio (CNR) in a dental cone beam computed tomography (CBCT). The Cu-filter thickness and tube voltage of the CBCT unit were varied in the range of 0.00-0.

View Article and Find Full Text PDF

Objectives: To quantify and validate the effect of pixel size on a digital intraoral radiographic system according to International Electrotechnical Commission standards through physical and visual evaluations.

Methods: The digital intraoral radiographic system used was the photostimulable phosphor imaging plate and scanner system. The system had three image capture modes: high-speed (HS), high-resolution (HR), and super high-resolution (SHR) with different pixels.

View Article and Find Full Text PDF

Understanding the properties of slice sensitivity profile (SSP), or slice thickness, is crucial for an accurate and highly reproducible diagnosis using tomosynthesis imaging. The objectives of the present study are therefore to quantitatively evaluate how the SSP with the use of a small metal bead is affected by different settings of the height from the table and the height of the center of rotation (COR) in tomosynthesis imaging except for the digital breast tomosynthesis, and visually verify the effects on tomosynthesis images. The reconstruction filters used were three types of filtered back-projection and iterative reconstructions.

View Article and Find Full Text PDF

Real-time radiation dose management is important because staff members working in interventional radiology may be exposed to relatively high doses of primary and scattered radiation from the body of a patient. In this study, we investigated the dependence of energy and dose rate of the commercially available semiconductor detector named Pocket Geiger (POKEGA) for personal monitoring in diagnostic X-rays. In the energy-dependence study, a suitable metal filter and the threshold level were examined for energy compensation using a Monte Carlo calculation code.

View Article and Find Full Text PDF

Because of the more advanced and more complex procedures in interventional radiology, longer treatment times have become necessary. Therefore, it is important to determine the exposure doses received by operators and patients. The aim of our study was to evaluate an experimental production wireless dose monitoring system for pulse radiation in diagnostic X-ray.

View Article and Find Full Text PDF