Background: This study evaluated the use of an augmented reality navigation system that provides a markerless registration system using stereo vision in oral and maxillofacial surgery.

Method: A feasibility study was performed on a subject, wherein a stereo camera was used for tracking and markerless registration. The computed tomography data obtained from the volunteer was used to create an integral videography image and a 3-dimensional rapid prototype model of the jaw.

View Article and Find Full Text PDF

To evaluate the feasibility and accuracy of a three-dimensional augmented reality system incorporating integral videography for imaging oral and maxillofacial regions, based on preoperative computed tomography data. Three-dimensional surface models of the jawbones, based on the computed tomography data, were used to create the integral videography images of a subject's maxillofacial area. The three-dimensional augmented reality system (integral videography display, computed tomography, a position tracker and a computer) was used to generate a three-dimensional overlay that was projected on the surgical site via a half-silvered mirror.

View Article and Find Full Text PDF

We have developed a new generation device called rigid-flexible outer sheath with multi-piercing surgery (MPS) to solve the issues of tissue closure, triangulation, and platform stability in natural orifice transluminal endoscopic surgery (NOTES), and the problems of restricted visual field, organ damage, and removing a resected organ from body in needlescopic surgery (NS). The shape of the flexible outer sheath can be selectively locked by a novel pneumatic shapelocking mechanism. Major features include four directional flexion at the distal end, four working channels, and suction and water jet functions.

View Article and Find Full Text PDF

Background: During endoscopic surgical procedures, surgeons must manipulate an endoscope inside the body cavity to observe a surgical area while estimating the distance between that area and the surgical instruments by reference to a monitor on which the movement and size of the surgical instruments are displayed in 2-D endoscopic images. Therefore, there is a risk of the endoscope or instruments physically damaging body tissues. To overcome this problem, we developed a Ø5-mm, 3-D endoscope using a single 1/10-inch CCD camera and pneumatic vibration mechanism.

View Article and Find Full Text PDF

Minimally invasive surgery is a widely used medical technique, one of the drawbacks of which is the loss of direct sense of touch during the operation. Palpation is the use of fingertips to explore and make fast assessments of tissue morphology. Although technologies are developed to equip minimally invasive surgery tools with haptic feedback capabilities, the majority focus on tissue stiffness profiling and tool-tissue interaction force measurement.

View Article and Find Full Text PDF

Conventional surgical navigation requires for surgeons to move their sight and conscious off the surgical field when checking surgical tool's positions shown on the display panel. Since that takes high risks of surgical exposure possibilities to the patient's body, we propose a novel method for guiding surgical tool position and orientation directly in the surgical field by a laser beam. In our navigation procedure, two cross-sectional planar laser beams are emitted from the two laser devices attached onto both sides of an optical localizer, and show surgical tool's entry position on the patient's body surface and its orientation on the side face of the surgical tool.

View Article and Find Full Text PDF

Purpose: In endoscopic surgery, surgeons must manipulate an endoscope inside the body cavity to observe a large field-of-view while estimating the distance between surgical instruments and the affected area by reference to the size or motion of the surgical instruments in 2-D endoscopic images on a monitor. Therefore, there is a risk of the endoscope or surgical instruments physically damaging body tissues. To overcome this problem, we developed a Ø7- mm 3-D endoscope that can switch between providing front and front-diagonal view 3-D images by simply rotating its sleeves.

View Article and Find Full Text PDF

Single port access (SPA) surgery is a laparoscopic procedure using only one transumbilical-placed port. Natural orifice transluminal endoscopic surgery (NOTES) offers the possibility of surgery without visible scars. To address the access and stability problems in SPA and NOTES, we developed a device called rigid-flexible outer sheath.

View Article and Find Full Text PDF

We present an augmented reality system for oral and maxillofacial surgery in this paper. Instead of being displayed on a separated screen, three-dimensional (3D) virtual presentations of osseous structures and soft tissues are projected onto the patient's body, providing surgeons with exact knowledge of depth information of high risk tissues inside the bone. We employ a 3D integral imaging technique which produce motion parallax in both horizontal and vertical direction over a wide viewing area in this study.

View Article and Find Full Text PDF

Background: To develop a new endoscope for performing simple surgical tasks inside the blood-filled cardiac atrium/chamber, that is, "off-pump" cardiac surgeries.

Methods: We developed the endoscope system with plasma flushing and coaxial round jet nozzle. The "plasma flushing" system was invented to observe the interior of the blood-filled heart by displacing blood cells in front of the endoscope tip.

View Article and Find Full Text PDF
Article Synopsis
  • Developed an autostereoscopic display that allows viewers to see 3D images without glasses or trackers, using a novel CG image generation method.
  • The images are created through a pixel distribution algorithm specifically for integral photography (IP) and integral videography (IV).
  • This technology enables long-distance, 3D visualization with minimal distortion, resulting in images that appear three-dimensional with significant depth when viewed from various angles.
View Article and Find Full Text PDF

One of the greatest difficulties in endoscopic surgery is the limited field-of-view (FOV) of endoscopes. During endoscopic manipulation in body cavities to expand the FOV, there is the risk of inadvertent damage to body tissues, nerves, and internal organs. The risk increases especially in surgery that is performed inside a very small cavity, or in which body tissues are very fragile.

View Article and Find Full Text PDF

A 3-D augmented reality navigation system using autostereoscopic images was developed for MRI-guided surgery. The 3-D images are created by employing an animated autostereoscopic image, integral videography (IV), which provides geometrically accurate 3-D spatial images and reproduces motion parallax without using any supplementary eyeglasses or tracking devices. The spatially projected 3-D images are superimposed onto the surgical area and viewed via a half-silvered mirror.

View Article and Find Full Text PDF

This paper describes a precision-guided surgical navigation system for minimally invasive surgery. The system combines a laser guidance technique with a three-dimensional (3D) autostereoscopic image overlay technique. Images of surgical anatomic structures superimposed onto the patient are created by employing an animated imaging method called integral videography (IV), which can display geometrically accurate 3D autostereoscopic images and reproduce motion parallax without the need for special viewing or tracking devices.

View Article and Find Full Text PDF

The purpose of this study is to develop a new endoscope for performing simple surgical tasks inside a cardiac atrium/chamber filled with blood, i.e., for performing "off-pump" cardiac surgeries.

View Article and Find Full Text PDF
Article Synopsis
  • Developed a nonmagnetic outer sheath that can switch between rigid and flexible modes for surgical use.
  • The device has a controlled bending distal end driven by nylon wires and is made from MRI-compatible plastics.
  • In tests on swine, it effectively inserted a flexible endoscope and biopsy forceps into hard-to-reach areas of the body, proving its utility for surgical procedures.
View Article and Find Full Text PDF

In this paper, we describe a rigid endoscope that transmits a laser beam coaxially to arbitrary points in the endoscopic view, mainly for treatment of twin-to-twin transfusion syndrome. The endoscope consists of a hotmirror for coaxial transmission of visible light and a Nd:YAG laser beam, and galvanometers for controlling the beam irradiation angle. We evaluated the transmission efficiency of the laser power, the spot size through the endoscope and accuracy in positioning the beam.

View Article and Find Full Text PDF

In this paper, detection of edges in oriented fields is addressed. In some applications such as vessel segmentation because of the intrinsic orientation of the structures, edge detection is only demanded in a particular subspace. This is specially usefull when a curve evolution is chosen for segmentation since gradients in parallel to vessel orientation may stop the contour.

View Article and Find Full Text PDF
Article Synopsis
  • Minimally invasive endoscopic fetal surgery is a technique that allows for safer intrauterine interventions with lower risks for both the mother and fetus, facilitated by a new surgical manipulator designed to stabilize the fetus.
  • The prototype manipulator features flexible joints, bending mechanisms, and a soft balloon stabilizer, enabling it to navigate the confined uterine space effectively under ultrasound guidance.
  • Initial accuracy tests show promising results, with small error margins, and the manipulator was successfully controlled with ultrasound guidance during experiments, indicating its potential for future use in fetal surgery with some needed refinements.
View Article and Find Full Text PDF

In this paper, a level-set-based geometric regularization method is proposed which has the ability to estimate the local orientation of the evolving front and utilize it as shape induced information for anisotropic propagation. We show that preserving anisotropic fronts can improve elongations of the extracted structures, while minimizing the risk of leakage. To that end, for an evolving front using its shape-offset level-set representation, a novel energy functional is defined.

View Article and Find Full Text PDF
Article Synopsis
  • A new adaptive 4D MR imaging method was developed for real-time visualization of respiratory organ motion during MRI-guided therapy, allowing for synchronization with actual organ movement.
  • This method was tested using phantoms and patients, demonstrating a low position error of 1.9 mm and successfully capturing 4D images of a liver tumor under clinical conditions.
  • The image quality varied based on factors like encoding direction and slice orientation, but overall, the method proved feasible for providing accurate dynamic 3D images for surgical navigation.
View Article and Find Full Text PDF

Evolutionary schemes based on the level set theory are effective tools for medical image segmentation. In this paper, a new variational technique for edge integration is presented. Region statistical measures and orientation information from ramp-like edges, are fused within an energy minimization scheme that is based on a new interpretation of edge concept.

View Article and Find Full Text PDF

We demonstrated that placing a pair of prism sheets in front of a display and rotating them overcomes the upper resolution limit of Integral Photograpy (IP) / Integral Videography (IV) imposed by the Nyquist sampling theorem. A pair of prism sheet with the same pitch placed in front of an IP or IV display parallel-shifts the light rays in the 3D space. Rotating the pair shifts the light rays, causing them to appear to rotate around their original positions.

View Article and Find Full Text PDF

The objective of this paper is to develop an outer sheath for flexible endoscopic manipulators. This sheath can switch two states including flexible and rigid, and make a rigid curved path for inserting manipulators. The flexible mode can be curved into a required shape.

View Article and Find Full Text PDF