Publications by authors named "Takero Hirata"

Article Synopsis
  • Radiotherapy can affect pacemakers and defibrillators, but its impact on patients with left ventricular assist devices (LVAD) is not well understood, prompting this study.
  • Three patients in their 50s and 60s with LVADs due to heart conditions underwent stereotactic ablative radiotherapy (SABR) for early-stage lung cancer, with careful planning to limit radiation exposure to the LVAD.
  • The treatment was completed without any immediate complications or LVAD malfunctions, and none of the patients experienced disease progression or long-term side effects during follow-up.
View Article and Find Full Text PDF

Background: Fractionated stereotactic radiosurgery (fSRS) is an important treatment strategy for unresected brain metastases. We previously reported that a good volumetric response 6 months after fSRS can be the first step for local control. Few studies have reported the association between gross tumor volume (GTV) dose, volumetric response, and local control in patients treated with the same number of fractions.

View Article and Find Full Text PDF

Purpose: Radiation therapy is widely used to treat head and neck squamous cell carcinoma (HNSCC). This study evaluated the association between circulating plasma programmed death-ligand 1 (PD-L1) and the outcomes of patients with HNSCC after radiation therapy.

Methods And Materials: In this retrospective observational study, plasma samples of 76 patients with HNSCC who underwent radiation therapy from June 2019 to August 2021 were analyzed.

View Article and Find Full Text PDF

Purpose: In this study, we developed in-house software to evaluate the effect of the lead block (LB)-inserted spacer on the mandibular dose in interstitial brachytherapy (ISBT) for tongue cancer. In addition, an inverse planning algorithm for LB attenuation was developed, and its performance in mandibular dose reduction was evaluated.

Methods: Treatment plans of 30 patients with tongue cancer treated with ISBT were evaluated.

View Article and Find Full Text PDF

Background: This dose-escalation study evaluated the toxicity and efficacy of different stereotactic body radiation therapy (SBRT) doses for selecting an optimal dose for prostatic adenocarcinoma (PCa).

Materials And Methods: This clinical trial was registered at UMIN (UMIN000014328). Patients with low- or intermediate-risk PCa were equally assigned to 3 SBRT dose levels: 35, 37.

View Article and Find Full Text PDF
Article Synopsis
  • - The study focuses on the immediate side effects from stereotactic radiotherapy (SRT) for brain metastases, analyzing data from 315 patients treated between May 2019 and February 2022.
  • - Out of 439 SRT sessions, only 3.6% of patients experienced significant side effects (Grade ≥ 2), with serious complications (Grade ≥ 3) found in just 1.6% of cases.
  • - Findings suggest that while SRT is generally safe, particularly for patients with multiple and large lesions, close monitoring for complications is still essential post-treatment.
View Article and Find Full Text PDF

Background: The CyberKnife system features a robotically-positioned linear accelerator to deliver real-time image-guided stereotactic ablative body radiotherapy (SABR). It achieves steep dose gradients using irradiation from hundreds of different directions and increases the central dose of the gross tumor volume (GTV) without increasing the marginal dose to the planning target volume. We evaluated the effectiveness and safety of SABR with a central high dose using CyberKnife for metastatic lung tumors.

View Article and Find Full Text PDF

Background/aim: This study evaluated the effects of the respiratory phase shifts between liver tumor and chest wall motions on the dose distribution for the CyberKnife Synchrony respiratory tracking system (SRTS).

Patients And Methods: Eight patients who received stereotactic body radiotherapy for hepatocellular carcinoma or liver metastases were analyzed. Three-dimensional (3D) motion of the implanted fiducial markers and vertical motion of the sternal bone were derived from the four-dimensional computed tomography (4D-CT) images acquired with a 320-row area detector CT.

View Article and Find Full Text PDF
Article Synopsis
  • The radiation recall phenomenon (RRP) is a rare complication that can occur after radiation therapy, sometimes triggered by treatments like anticancer drugs or COVID-19 vaccines.
  • A case study involving a 50-year-old woman showed that after her larynx radiation therapy and treatment with ramucirumab, she experienced RRP, characterized by symptoms like sore throat and mucosal bleeding.
  • After receiving the Pfizer-BioNTech COVID-19 vaccine, her symptoms worsened, leading to hospitalization and steroid treatment, highlighting the need to consider RRP as a potential risk when administering vaccines to patients with a history of radiation therapy.
View Article and Find Full Text PDF

Background/aim: This study aimed to evaluate the treatment outcomes of radiation therapy (RT) for localized prostate cancer in elderly patients aged ≥75 years.

Patients And Methods: We retrospectively investigated data of patients aged ≥75 years with prostate cancer who underwent intensity-modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT) with doses of 70-78 Gy in 35-39 fractions between September 2008 and June 2016. Overall survival (OS), recurrence-free (RF) rates, and occurrence rates of toxicities were calculated.

View Article and Find Full Text PDF

Background And Purpose: Few reports include volumetric measurements as endpoints after stereotactic radiotherapy (SRT) despite the importance of such measurements. This study aimed to (1) investigate the impact of the volumetric response (specifically, an over 65% and over 90% volume reduction in brain metastases) at 6 months post-SRT on local control and (2) identify the predictive factors for a volumetric response of over 65% and over 90%.

Materials And Methods: This study included 250 unresected brain metastases (>0.

View Article and Find Full Text PDF

Purpose: This study introduced an A-mode portable ultrasound bladder scanner, the Lilium® α-200 (here after Lilium; Lilium Otsuka, Kanagawa, Japan), for the treatment of prostate cancer patients with hypofractionated volumetric modulated arc therapy to improve the reproducibility of bladder volume (BV).

Materials And Methods: Thirty patients were advised to maintain full BV prior to computed tomography (CT) simulation and daily treatment. Among these, the BV of 15 patients was measured using Lilium until a BV of 80% in the simulation was achieved (with the Lilium group).

View Article and Find Full Text PDF

Background/aim: We evaluated the effectiveness and safety of stereotactic ablative radiotherapy (SABR) delivered using Cyberknife in patients with stage I non-small-cell lung cancer.

Patients And Methods: The clinical results of 153 patients with 161 lung cancers treated with CyberKnife between May 2014 and August 2020 at the Osaka University Hospital were retrospectively analyzed. The median age was 80 years (range=48-99 years).

View Article and Find Full Text PDF

Previous studies have reported conflicting results for the effect of overall treatment time with stereotactic body radiotherapy on tumor control in early-stage non-small-cell lung cancer. To examine this effect, we conducted a propensity score-weighted, retrospective, observational study at a single institution. We analyzed the data of 200 patients with early-stage non-small-cell lung cancer who underwent stereotactic body radiotherapy (48 Gy in 4 fractions) at our institution between January 2007 and October 2013.

View Article and Find Full Text PDF
Article Synopsis
  • The study evaluates the image quality and respiratory motion of hepatocellular carcinoma with portal vein tumor thrombosis (PVTT) using a new imaging technique called contrast-enhanced four-dimensional dual-energy computed tomography (CE-4D-DECT).
  • The results show that the optimal virtual monochromatic image (O-VMI) at 60 keV has significantly higher contrast to noise ratio and overall image quality compared to the standard virtual monochromatic image (S-VMI) at 77 keV.
  • Additionally, the diaphragm's motion during respiration was found to be greater than that of the tumor, indicating the need for careful localization in radiotherapy to ensure accurate targeting.
View Article and Find Full Text PDF

In this study, we evaluated the inter-unit variability of the lateral response artifact for multiple flatbed scanners, focusing on the dual-channel method, and investigated the correction method of the lateral non-uniformity. Four scanners with A3+ paper-size and five scanners with A4 paper-size were evaluated. To generate the dose-response curves, small pieces of the Gafchromic EBT3 and EBT-XD films were irradiated, and five of the pieces were repeatedly scanned by moving them on the scanner to evaluate the lateral non-uniformity.

View Article and Find Full Text PDF

Background: Previous studies reported that cigarette smoking during radiation therapy was associated with unfavorable outcomes in various cancers using medical interviewing or monitoring of cotinine. Here, we evaluated the effect of smoking cessation on definitive radiation therapy for early stage glottic carcinoma by monitoring expiratory carbon monoxide (CO).

Material And Methods: We enrolled 103 patients with early glottic carcinoma (T1N0/T2N0 = 79/24) who underwent conventional radiotherapy between 2005 and 2016.

View Article and Find Full Text PDF

Background/aim: The aim of this retrospective study was to detect the frequency, reasons, and significant factors for not receiving immunotherapy after chemoradiotherapy in non-small cell lung cancer (NSCLC) patients.

Patients And Methods: Thirty-four patients with NSCLC received definitive chemoradiotherapy. The endpoint of this study was receiving durvalumab within 45 days after chemoradiotherapy for NSCLC.

View Article and Find Full Text PDF

Purpose: This study investigated the characteristics of a new shielded diode detector, microSilicon X (model 60022: MSX), for small-field and large-field dosimetry.

Methods: The percent depth dose (PDD), beam profiles, detector output factor (OF ), temperature dependence, dose rate dependence, dose-per-pulse (DPP) dependence, and dose-response linearity of MSX were evaluated in Cyberknife and TrueBeam photon beams and compared with various detectors including microDiamond (PTW model 60019: MD), Sun Nuclear EDGE detector, Photon diode (PTW model 60016: PD), and semiflex ionization chamber (PTW model 31010: IC).

Results: For field sizes ranging from 50 × 50 mm to 400 × 400 mm , MSX-measured OF values were within 1% of the IC-measured values.

View Article and Find Full Text PDF

The goal of total body irradiation (TBI) is to deliver a dose to the whole body with uniformity within ±10%. The purpose of this study was to establish the technique of TBI using plastic bead bags. A lifting TBI bed, Model ORP-TBI-MN, was used.

View Article and Find Full Text PDF
Article Synopsis
  • * Among 391 patients treated between 2006 and 2014, a significant number died from various causes, with notable risk factors identified as having a previous surgery for esophageal cancer and receiving simultaneous RT for synchronous esophageal cancer.
  • * The findings suggest that while RT can preserve the larynx in HSC patients, it should be approached carefully in those with a history of esophageal cancer-related treatments due to increased risks of non-cancer deaths.
View Article and Find Full Text PDF
Article Synopsis
  • * CT scans showed cancer returning, compressing the left internal carotid artery, leading to a diagnosis of tumor-induced carotid sinus syndrome (tiCSS).
  • * After starting palliative intensity-modulated radiotherapy (IMRT), his symptoms improved within ten days, demonstrating that this minimally invasive treatment is a viable option for similar patients with poor prognosis.
View Article and Find Full Text PDF

Background: The present study aimed to evaluate the toxicity and efficacy of stereotactic body radiotherapy (SBRT) for localized prostate cancer.

Patients And Methods: We investigated 25 patients treated with SBRT of 35 Gy per five fractions from May 2014 to March 2015.

Results: The median age of patients was 70 years, four (16%) patients were low risk and 21 (84%) were intermediate risk.

View Article and Find Full Text PDF

The prognosis of hepatocellular carcinoma (HCC) with portal vein tumour thrombus (PVTT) is poor. We conducted a prospective study to evaluate the efficacy and safety of tri-modality therapy, including preoperative stereotactic body radiotherapy (SBRT) and surgery, followed by hepatic arterial infusion chemotherapy (HAIC) in HCC patients with PVTT. In this report, we investigated the pathology of the irradiated PVTT specimen in resected cases and SBRT-related acute toxicity.

View Article and Find Full Text PDF

Background: The present study aimed to estimate geometric changes in applicators and prostate over 3 days in patients with high-dose-rate brachytherapy (HDR-BT) and to assess the need for daily replanning.

Patients And Methods: This study retrospectively investigated 18 patients who underwent HDR-BT as monotherapy from February 2016 to October 2018.

Results: Without replanning, the planning target volume coverage significantly worsened on day 2 (p<0.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session5u58g9c5drtk82e148ok169g9rq10aht): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once