Currently, the OECD has adopted three defined approaches (DAs) for eye hazard identification of non-surfactant liquids and solids (TG467) according to the three UN GHS categories (Cat.1, Cat.2, No Cat.
View Article and Find Full Text PDFThe Short Time Exposure (STE) test evaluates eye irritation potential using a 3-(4,5-di-methylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. MTT assays may underpredict results for some substances that directly reduce MTT (i.e.
View Article and Find Full Text PDFThe Short Time Exposure (STE) test method is an in vitro method for assessing the eye irritation potential of chemicals and is used to classify the Globally Harmonized System of Classification and Labelling of Chemicals (GHS) Category 1 and No Category (NC). The method has been adopted by the Organisation for Economic Co-operation and Development (OECD) as test guideline (TG) 491 since 2015. While this method can be used to classify GHS NC, it is not suitable for testing highly volatile substances and solids other than surfactants.
View Article and Find Full Text PDFThe Short Time Exposure (STE) test method is an alternative method for assessing eye irritation potential using Statens Seruminstitut Rabbit Cornea cells and has been adopted as test guideline 491 by the Organisation for Economic Co-operation and Development. Its good predictive performance in identifying the Globally Harmonized System (GHS) No Category (NC) or Irritant Category has been demonstrated in evaluations of water-soluble substances, oil-soluble substances, and water-soluble mixtures. However, the predictive performance for oil-soluble mixtures was not evaluated.
View Article and Find Full Text PDFThe Short Time Exposure (STE) test is an in vitro eye irritation test based on the cytotoxicity in SIRC cells (rabbit corneal cell line) following a 5 min treatment of chemicals. This study evaluated the predictive performance of the STE test to identify the globally harmonized system (GHS) Not Classified category and other irritant categories (i.e.
View Article and Find Full Text PDFThe Short Time Exposure (STE) test is a simple and easy-to-perform in vitro eye irritation test, that uses the viability of SIRC cells (a rabbit corneal cell line) treated for five minutes as the endpoint. In this study, our goal was to define the applicability domain of the STE test, based on the results obtained with a set of 113 substances. To achieve this goal, chemicals were selected to represent both different chemical classes and different chemical properties, as well as to cover, in a balanced manner, the categories of eye irritation potential according to the Globally Harmonised System (GHS).
View Article and Find Full Text PDFFor the assessment of eye irritation, one alternative test may not completely replace the rabbit Draize test. In the present study, we examined the predictive potential of a tiered approach analyzing the results from several alternatives (i.e.
View Article and Find Full Text PDFFor the evaluation of eye irritation, one in vitro alternative test may not completely replace the Draize test. Therefore, a tiered approach combining several in vitro assays, including cytotoxicity assays, is proposed in order to estimate the eye irritation potential of a wide range of chemical classes. The Short Time Exposure (STE) test, a relatively newer alternative eye irritation test, involves exposing Statens seruminstitut rabbit cornea (SIRC) cells for 5 min to two concentrations (5% and 0.
View Article and Find Full Text PDFShort Time Exposure (STE) test is an easy in vitro eye irritation test that assesses cytotoxicity in SIRC cells (rabbit corneal cell line) following a 5 min dose treatment. To assess intra-laboratory reproducibility, medium control, three vehicles (saline, saline containing 5% (w/w) dimethyl sulfoxide, and mineral oil) and three standard chemicals (sodium lauryl sulfate, calcium thioglycolate, and Tween 80) were evaluated. Assessments were repeated 30 times for vehicles and 18 times for standard chemicals; resulting in almost the same cell viability and a low coefficient of variation value.
View Article and Find Full Text PDF