Nihon Hoshasen Gijutsu Gakkai Zasshi
December 2024
Purpose: The purpose of this study was to evaluate the effect of patient transfer slide boards with automatic couch height positioning compensation (AHC) on image quality and radiation dose during computed tomography (CT) examinations.
Methods: The chest phantom for Kyoto Kagaku (Kyoto) Type PBU-SS 2 was performed helical scan using a Canon Medical Systems (Tochigi) 80-row CT Aquilion Prime SP/i Edition. Scan parameters were tube voltage: 120 kV, tube current: min 50 mA max 500 mA with AHC for noise index: 15, slice thickness: 5.
We compared the computed tomography (CT) numbers from monochromatic images obtained using the first-generation (Discovery CT750 HD: GE Healthcare, Milwaukee, WI) and second-generation (Revolution CT: GE HealthCare) dual-energy CT (first and second DECT) scanners in phantom and clinical studies. In a polypropylene phantom, eight polypropylene tubes containing iodine at various concentrations (0.5, 1, 2, 5, 10, 12, 20, 30 mg I per ml) were arranged in an outer circle.
View Article and Find Full Text PDFEquivalent doses for the eye lenses, thyroid, and mammary glands were measured and compared between one adult and three pediatric anthropomorphic phantoms during chest computed tomography (CT) using 40 mm volume helical scan on the Aquilion ONE GENESIS Edition CT equipment. Placing an optically stimulated luminescence dosemeter (OSLD) on the eye lenses, thyroid, and mammary gland, we measured and compared the equivalent dose of OSLD among different phantoms during chest CT using a helical scan. Compared with adults, the equivalent doses to the eye lens, thyroid, and mammary glands were ~81%, 77%, and 63% lower in newborns, 1-year-olds, and 5-year-olds using comparable image noise during chest CT.
View Article and Find Full Text PDFBackground: Reports comparing field lens doses between helical scans with a 40-mm detector width and axial scans with a 160-mm detector width using different computed tomography (CT) scanners are currently scarce.
Objective: To compare scatter doses for lenses between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width when using different CT scanners in the context of pediatric chest examinations.
Materials And Methods: Two different CT machines were used: Revolution CT (GE Healthcare, Waukesha, WI) with a 256-row, 0.
Pepper mild mottle virus (PMMoV) has been proposed as a potential indicator of human enteric viruses in environmental water and for viral removal during drinking water treatment. To investigate the occurrence and present forms of PMMoV and quantitative relations to norovirus GII and rotavirus A (RVA) in surface waters, 147 source water samples were collected from 21 drinking water treatment plants (DWTPs) in Japan between January 2018 and January 2021, and the concentrations of viruses in suspended and dissolved fractions were measured using real-time RT-PCR. PMMoV was detected in 81-100 % of samples in each sample month and observed concentrations ranged from 3.
View Article and Find Full Text PDFThe purpose of this study was to investigate the risk of overexposure associated with automatic tube current modulation (ATCM) and automatic couch height positioning compensation mechanism (AHC) in computed tomography (CT) systems, particularly in scenarios involving a gap between the subject and the couch. Results revealed that when AHC was enabled, CT dose index volume (CTDI) increased by approximately 10% at 2.5 cm, 20% at 5.
View Article and Find Full Text PDFBackground: Adaptive collimation reduces the dose deposited outside the imaged volume along the z-axis. An increase in the dose deposited outside the imaged volume (to the lens and thyroid) in the z-axis direction is a concern in paediatric computed tomography (CT).
Objective: To compare the dose deposited outside the imaged volume (to the lens and thyroid) between 40-mm and 80-mm collimation during thoracic paediatric helical CT.
Nihon Hoshasen Gijutsu Gakkai Zasshi
February 2024
The purpose of this study was to investigate the correlation between patient characteristics and contrast enhancement during the hepatic arterial phase (HAP) and portal venous phase (PVP) CT scanning. All were examined using a hepatic dynamic CT protocol; the scanning parameters were tube voltage 120 kVp, tube current 50 to 600 mA (noise index 8.0 HU), 0.
View Article and Find Full Text PDFTo determine whether using lower-tube voltage reduces the scattered dose for the lens during paediatric thoracic computed tomography (CT). Two paediatric anthropomorphic phantoms (ATOM Phantom, CIRS, Norfolk, Virginia, USA) representing a newborn and 5-year-old were placed on the gantry of CT scanner, and optically stimulated luminescence dosemeters were placed on the left and right lenses, in front of the left and right thyroid glands, in front of the left and right mammary glands, and in front of and behind the mammary gland level and we measured scattered dose of the optically stimulated luminescence dosemeter was compared for each phantom between 80 and 120 kVp. Significant differences were observed in the scatter doses for the lens between 80 and 120 kVp (p < 0.
View Article and Find Full Text PDFThe aim of this study was to estimate the effect of tube voltage on the scattered dose in a computed tomography (CT) room. To this end, we conducted experiments using anthropomorphic phantoms and a CT scanner at different tube voltages during CT. The scattered dose was measured using an electronic pocket dosemeter at 50-cm intervals from the centre of the gantry.
View Article and Find Full Text PDFObjectives: To evaluate the depiction of wrist tendons in virtual monochromatic images (VMIs) during a dual-energy CT (DE-CT) with the VMI image of conventional equivalent to 120 kVp.
Materials And Methods: Using Catphan600 and phantom analysis software for CT evaluation, measurements of VMI in a DE-CT were performed corresponding to the tube voltages of single-energy CT at 120 kVp. Using a Discovery CT750 HD CT scanner (GE Healthcare) with DE-CT technology, 73 patients were scanned.
Objectives: This study aimed to investigate whether machine learning (ML) is useful for predicting the contrast material (CM) dose required to obtain a clinically optimal contrast enhancement in hepatic dynamic computed tomography (CT).
Methods: We trained and evaluated ensemble ML regressors to predict the CM doses needed for optimal enhancement in hepatic dynamic CT using 236 patients for a training data set and 94 patients for a test data set. After the ML training, we randomly divided using the ML-based (n = 100) and the body weight (BW)-based protocols (n = 100) by the prospective trial.
We investigated the effect of electrocardiographic (ECG) mA-modulation of ECG-gated scans of computed tomography (CTA) on radiation dose and image noise at high heart rates (HR) above 100 bpm between helical pitches (HP) 0.16 and 0.24.
View Article and Find Full Text PDFTo propose reference values for air-kerma at the reference point (Ka,r), air-kerma area product (PKA), fluoroscopy time (FT) and number of cine images (CI) for four age groups in Japan, a nationwide questionnaire was posted to 132 pediatric catheterisation of certified facility in Japan, using the conventional post system, to which 43 facilities responded. For diagnostic cardiac angiography, reference values were as follows: Ka,r: 86, 102, 165 and 264 mGy; PKA: 9.3, 9.
View Article and Find Full Text PDFTo evaluate the effects of various patient characteristics on vessel enhancement on arterio-venous fistula (AVF) computed tomography (CT) angiography (AVF-CT angiography). A total of 127 patients with suspected or confirmed shunt stenosis and internal AVF complications were considered for inclusion in a retrospective cohort study. The tube voltage was 120 kVp, and the tube current was changed from 300 to 770 mA to maintain the image quality (noise index: 14) using automatic tube current modulation.
View Article and Find Full Text PDFTo compare the radiation dose and diagnostic ability of the 100-kVp protocol, based on the contrast noise ratio (CNR) index, during coronary artery bypass graft (CABG) vessels with those of the 120-kVp protocol. For the 120-kVp scans (150 patients), the targeted image level was set at 25 Hounsfield units (HU) (CNR120 = iodine contrast/25 HU). For the 100-kVp scans (150 patients), the targeted noise level was set at 30 HU to obtain the same CNR as in the 120-kVp scans (i.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
May 2023
Purpose: To compare the diagnostic capabilities of orbital synchronized helical scanning at lower extremity computed tomography angiography between the Add/Sub software and the deformable image registration.
Methods: From March 2015 to December 2016, 100 dialysis patients underwent orbital synchronized lower limb CT subtraction angiography and lower limb endovascular treatment within 4 months. For the visual evaluation of blood vessels in the lower extremities, a stenosis rate of 50% or more was considered to be stenosis.
Background: To investigate optimizing the use of different beam shaping filters (viz. small, medium and large) when using different tube voltages during the newborn chest computed tomography (CT) on a GE Lightspeed VCT scanner.
Methods: We used pediatric anthropomorphic phantoms with a 64 detector-row CT scanner while scanning the chest.
To compare the computed tomography (CT) number and the radiation dose between the 64 (group A) and 80-detector row (group B) during lower extremity computed tomography angiography (LE-CTA). We enrolled 144 patients underwent LE-CTA and compared the CT number for the popliteal arteries, radiation dose and the rate of the optimal CT number during the LE-CTA exceeding 200 HU between the two groups. The CT number for the popliteal arteries and mean dose-length product was significantly higher in Group A than in Group B (P < 0.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
January 2023
The radiological technologists often assist patients near the X-ray area during mobile radiography. Therefore, it is expected that the lens of eye of radiological technologists is exposed to much radiation. The purposes of this study were to measure the lens dose received by radiological technologists during mobile radiography using radiation protection goggles with a personal dosimeter and a small optically stimulated luminescence dosimeter and discuss the need for radiation protection goggles and additional radiation protection measures.
View Article and Find Full Text PDF