The expected role of medical technologists within diabetes mellitus education teams was surveyed. In addition to items regarding laboratory examinations and results themselves, good communication with patients and education team members was highly required. When medical technologists sufficiently follow this role, it would aid patients to cope with life with diabetes mellitus.
View Article and Find Full Text PDFA fast, simple, and sensitive flow injection analysis method was developed for the measurement of semicarbazide-sensitive amine oxidase (SSAO) activity in human serum. Benzaldehyde, generated by the action of SSAO after incubation of serum with benzylamine, was derivatized with a novel aromatic aldehyde-specific reagent (1,2-diaminoanthraquinone) and the fluorescent product was measured by fluorescence detection at excitation and emission wavelengths of 390 and 570nm, respectively. Serum SSAO activity was defined as benzaldehyde (nmol) formed per milliliter serum per hour.
View Article and Find Full Text PDFAcrolein is a major unsaturated aldehyde that is generated during the lipid peroxidation process. The measurement of acrolein in biological samples should be useful to estimate the degree of lipid peroxidation and to evaluate the effect of hazardous properties of acrolein on human health. In this study, a highly sensitive and selective high-performance liquid chromatography with fluorescence detection method was developed for the determination of acrolein in human serum.
View Article and Find Full Text PDF4-Hydroxy-2-nonenal (4HNE) is a major aldehyde generated during lipid peroxidation. The clinical monitoring of 4HNE in biological fluids could be useful for the early diagnosis of several diseases involving lipid peroxidation, such as rheumatoid arthritis, Parkinson's disease and cancer. In this study, an HPLC with fluorescence detection method was developed for the determination of 4HNE in human serum.
View Article and Find Full Text PDF4-Hydroxy-2-nonenal (4HNE) is a major aldehyde generated during lipid peroxidation. The clinical monitoring of 4HNE in biological fluids should be useful for the early diagnosis of several diseases involving lipid peroxidation, such as rheumatoid arthritis, Parkinson's disease and cancer. In this study, an HPLC with fluorescence detection method was developed for the determination of 4HNE in human serum.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
March 2014
A highly sensitive, selective and reproducible chromatographic method is described for determination of low-molecular mass unsaturated aliphatic aldehydes in human serum. The method combines fluorescent labeling using 4-(N,N-Dimethylaminosulfonyl)-7-hydrazino-2,1,3-benzoxadiazole with peroxyoxalate chemiluminescence. The derivatives were separated on a reversed-phase column C8 isocratically using a mixture of acetonitrile and 90mM imidazole-HNO3 buffer (pH 6.
View Article and Find Full Text PDFA simple and selective HPLC-fluorescence (FL) method with FL probe, 4-[4-(4-dimethylaminophenyl)-5-phenyl-1H-imidazol-2-yl]benzoic acid methyl ester (DAPIM), for simultaneous determination of mercaptalbumin (HMA) and nonmercaptalbumin (HNA1) was developed. After HMA and HNA1 were separated on an ion-exchange column, they were on-line and post-column mixed with DAPIM. The DAPIM-albumin complex produces FL (λex 370nm and λem 510nm); however, DAPIM solution never gives the FL.
View Article and Find Full Text PDFVitamin K is a fat-soluble vitamin involved in blood coagulation and bone metabolism. The detection and monitoring of vitamin K homologues in rheumatoid arthritis (RA) patients is a challenging problem due to the smaller concentrations of vitamin K and the presence of several interfering medications. Therefore, this study aimed to develop a new highly sensitive and selective chemiluminescence (CL) method designated to quantify vitamin K homologues in plasma of RA patients including phylloquinone (PK, vitamin K(1)), menaquinone-4 (MK-4, vitamin K(2)) and menaquinone-7 (MK-7, vitamin K(2)).
View Article and Find Full Text PDFObjective: The aim of this study was to evaluate whether serum COMP can estimate the therapeutic response of RA after 6 months of treatment with etanercept.
Methods: Forty-five RA patients receiving 25 mg of etanercept twice a week for 6 months were registered in this prospective observational study. Clinical response to the therapy was evaluated by DAS 28.
Background: There is a growing evidence that reactive oxygen species (ROS) may cause many pathologic conditions including chronic diseases, neurodegenerative disorders, cancer and aging. There are a number of methods to measure the total antioxidative activity of the serum. However, since the lifetime and oxidative activity of various types of ROS are all different, to measure simply the total antioxidative activity of the serum is not enough.
View Article and Find Full Text PDFWe investigated the effects of anti-IL-6 receptor antibody, tocilizumab (TCZ), on lipid metabolism. Nineteen patients with rheumatoid arthritis (RA), entered in clinical case-control study of SAMURAI trial at Sasebo Chuo Hospital, were examined. Nine patients received TCZ monotherapy at 8 mg/kg intravenously every 4 weeks (TCZ group) and 10 patients received conventional DMARDs (control group).
View Article and Find Full Text PDF