Publications by authors named "Takafumi Taniguchi"

Article Synopsis
  • The study aimed to evaluate the edge artifacts in PET images reconstructed using the point-spread function (PSF) algorithm at varying levels of radioactivity (SBRs).
  • Researchers used a body phantom with different sized spheres, acquiring PET data and comparing images reconstructed with OSEM and OSEM + PSF methods.
  • Results showed that as SBR increased, edge artifacts in the PSF images became more pronounced, particularly in smaller spheres, where a sharp peak was noted in low SBR conditions.
View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate the effect of the point spread function (PSF) and time of flight (TOF) on PET/CT images of overweight patients in relation to the iteration number and the acquisition time.

Methods: This study consisted of a phantom study and a clinical study. The NEMA IEC body phantom and a 40 cm diameter large phantom (LG phantom) simulating an overweight patient were used in this study.

View Article and Find Full Text PDF

Objective: We evaluated the accuracy of amplitude gating PET (AG-PET) compared with phase gating PET (PG-PET) in relation to respiratory motion patterns based on a phantom analysis.

Method: We used a NEMA IEC body phantom filled with an (18)F solution with a 4:1 sphere-to-background radioactivity ratio (12.6 and 2.

View Article and Find Full Text PDF

Unlabelled: The aim of this study was to evaluate the imaging performance of 39- and 52-ring time-of-flight (TOF) PET/CT scanners. We also assessed the potential of reducing the scanning time using a 52-ring TOF PET/CT scanner.

Methods: PET/CT scanners with 39- and 52-ring lutetium oxyorthosilicate detectors were evaluated.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the effects of point-spread function (PSF) and time-of-flight (TOF) on the standardized uptake value (SUV) of lymph node metastasis in FDG-PET/CT.

Materials And Methods: This study evaluated 41 lymph node metastases in 15 patients who had undergone (18)F-FDG PET/CT. The lesion diameters were 2.

View Article and Find Full Text PDF

Unlabelled: The PET image quality of overweight patients and patients who receive low injected doses deteriorates because of increases in statistical noise. The purpose of this study was to investigate the benefits of the point-spread function (PSF) and time-of-flight (TOF) for PET/CT image quality in such patients.

Methods: The PET images were reconstructed using the baseline ordered-subsets expectation-maximization algorithm (OSEM), OSEM + PSF, OSEM + TOF, and OSEM + PSF + TOF.

View Article and Find Full Text PDF

Unlabelled: The aim of this study was to investigate the effects of the point-spread function (PSF) and time-of-flight (TOF) on improving (18)F-FDG PET/CT images in relation to reconstruction parameters and noise-equivalent counts (NEC).

Methods: This study consisted of a phantom study and a retrospective analysis of 39 consecutive patients who underwent clinical (18)F-FDG PET/CT. The body phantom of the National Electrical Manufacturers Association and International Electrotechnical Commission with a 10-mm-diameter sphere was filled with an (18)F-FDG solution with a 4:1 radioactivity ratio compared with the background.

View Article and Find Full Text PDF