Background: Numerous studies have indicated that increased obesity in patients with established peripheral artery disease (PAD) is inversely associated with disease prognosis, a phenomenon coined as the "obesity paradox". A major cause of criticism in studies investigating the obesity paradox is the use of body mass index (BMI) as a surrogate marker in defining and quantifying the degree or severity of obesity. We conducted a retrospective review to verify whether the obesity paradox persists in patients with PAD when using body surface area (BSA) as an alternative anthropometric measure.
View Article and Find Full Text PDFObjectives: This study assess the feasibility of integrating virtual reality (VR) simulation into the central venous catheter (CVC) placement training curriculum.
Design: The study consists of 3 parts: (1) Evaluating current manikin-based training for CVC placement through surveys for senior first-year anesthesia residents and cardiac anesthesia faculty who supervise resident performing the procedure; (2) Interventional study training novice trainees with VR simulator and assessing their reaction satisfaction; and (3) pilot study integrating VR training sessions into CVC training curriculum for first-year anesthesia residents.
Setting: Conducted at a single academic-affiliated medical center from December 2022 to August 2023.
New artificial intelligence tools have been developed that have implications for medical usage. Large language models (LLMs), such as the widely used ChatGPT developed by OpenAI, have not been explored in the context of anesthesiology education. Understanding the reliability of various publicly available LLMs for medical specialties could offer insight into their understanding of the physiology, pharmacology, and practical applications of anesthesiology.
View Article and Find Full Text PDFDouble orifice mitral valve is a rare congenital anomaly that is often associated with other congenital cardiac abnormalities. Patients may present with valvular dysfunction or may be asymptomatic and have an incidental diagnosis of double outlet mitral valve. Whether symptoms due to this pathology are present or not it is important to accurately characterize this lesion.
View Article and Find Full Text PDFInvasive procedures are associated with adverse events that are both hazardous to patients and expensive to treat. A trainee is expected to perform complex sterile invasive procedures in a dynamic environment under time pressure while maintaining patient safety at the highest standard of care. For mastery in performing an invasive procedure, the automatism of the technical aspects is required, as well as the ability to adapt to patient conditions, anatomic variability, and environmental stressors.
View Article and Find Full Text PDFTranscatheter edge-to-edge repair (TEER) of the mitral valve is a complex procedure requiring continuous image guidance with 2-dimensional and 3-dimensional transesophageal echocardiography. In this context, the role of the echocardiographer is of paramount importance. Training in interventional echocardiography for procedures such as TEER requires comprehending the complicated workflow of the hybrid operating room and advanced imaging skills that go beyond traditional echocardiography training to guide the procedure.
View Article and Find Full Text PDFJ Cardiothorac Vasc Anesth
September 2023
Simulation-based training is an essential component in the education of transthoracic echocardiography (TTE). Nevertheless, current TTE teaching methods may be subject to certain limitations. Hence, the authors in this study aimed to invent a novel TTE training system employing three-dimensional (3D) printing technology to teach the basic principles and psychomotor skills of TTE imaging more intuitively and understandably.
View Article and Find Full Text PDFThe clinical utility of transesophageal echocardiography (TEE) is well-established for patients undergoing cardiac surgery. With the increase in percutaneous structural heart disease procedures that rely on TEE for procedural guidance, the use of TEE probes is expanding. Although there are well-established protocols for routine cleaning and decontaminating TEE probes between patient use, there is a lack of awareness and misconceptions about maintaining TEE probes' structural and electrical integrity.
View Article and Find Full Text PDFTransseptal puncture is an increasingly common procedure undertaken to gain access to the left side of the heart during structural heart disease interventions. Precision guidance during this procedure is paramount to ensure success and patient safety. As such, multimodality imaging, such as echocardiography, fluoroscopy, and fusion imaging, is routinely used to guide safe transseptal puncture.
View Article and Find Full Text PDFJ Community Hosp Intern Med Perspect
January 2023
The aim of this report is to explore the direct and long-term outcome in a high risk patient who was treated with rotational atherectomy (RA) to assist the placement of drug eluting stents in heavily calcified lesions. The patient presented with acute STEMI and had severely calcified Left main stem (LMS) disease, requiring plaque modification before coronary angioplasty and stent implantation. As the patient was elderly, with multiple comorbids including a number of coronary interventions, a decision of conservative management was made.
View Article and Find Full Text PDF