When screening microbial populations or consortia for interesting cells, their selective retrieval for further study can be of great interest. To this end, traditional fluorescence activated cell sorting (FACS) and optical tweezers (OT) enabled methods have typically been used. However, the former, although allowing cell sorting, fails to track dynamic cell behavior, while the latter has been limited to complex channel-based microfluidic platforms.
View Article and Find Full Text PDFWe present an innovative, simple, and versatile hydrophobic valve enabling all-important complex liquid manipulations on self-powered, channel-based microfluidic devices and as such being extremely valuable for the design of highly demanding point-of-care (POC) platforms. The presented hydrophobic valve is made of filter paper treated with a fluorinated compound (i.e.
View Article and Find Full Text PDFDetection methods that do not rely on the amplification of DNA but can reach sensitivity, specificity and throughput of gold standard methods, such as qPCR, have been extensively explored in recent years. Here, we present a hydrophilic-in-hydrophobic (HIH)-microwell array platform that empowers a panel of different amplification-free DNA bioassays: digital enzyme-linked oligonucleotide assay (ELONA), ligation-assisted (LA) digital ELONA and so-called 'analog' bioassays. We developed all three bioassays by using magnetic beads for capturing DNA target, followed by hybridization of enzyme-labelled detection probes and sealing of the built complexes into the femtoliter HIH microwells to achieve the fluorescent readout of single DNA molecules.
View Article and Find Full Text PDFIn this work, we present a new iSIMPLE concept (infusion Self-powered Imbibing Microfluidic Pump by Liquid Encapsulation), which requires no external power for activation nor liquid manipulation, it is easy to use while its fabrication method is extremely simple, inexpensive and suited for mass replication. The pump consists of a working liquid, which is - after finger activation - absorbed in a porous material (e.g.
View Article and Find Full Text PDFThe lab-on-a-chip (LOC) field has witnessed an excess of new technology concepts, especially for the point-of-care (POC) applications. However, only few concepts reached the POC market often because of challenging integration with pumping and detection systems as well as with complex biological assays. Recently, a new technology termed SIMPLE was introduced as a promising POC platform due to its features of being self-powered, autonomous in liquid manipulations, cost-effective and amenable to mass production.
View Article and Find Full Text PDFAmphotericin B (AmB) induces oxidative and nitrosative stresses, characterized by production of reactive oxygen and nitrogen species, in fungi. Yet, how these toxic species contribute to AmB-induced fungal cell death is unclear. We investigated the role of superoxide and nitric oxide radicals in AmB's fungicidal activity in using a digital microfluidic platform, which enabled monitoring individual cells at a spatiotemporal resolution, and plating assays.
View Article and Find Full Text PDFBead-based microwell array technology is growing as an ultrasensitive analysis tool as exemplified by the successful commercial applications from Illumina and Quanterix for nucleic acid analysis and ultrasensitive protein measurements, respectively. High-efficiency seeding of magnetic beads is key for these applications and is enhanced by hydrophilic-in-hydrophobic microwell arrays, which are unfortunately often expensive or labor-intensive to manufacture. Here, we demonstrate a new single-step manufacturing approach for imprinting cheap and disposable hydrophilic-in-hydrophobic microwell arrays suitable for digital bioassays.
View Article and Find Full Text PDFDigital microfluidics has emerged in the last years as a promising liquid handling technology for a variety of applications. Here, we describe in detail how to build up an electrowetting-on-dielectric-based digital microfluidic chip with unique advantages for performing single-molecule detection. We illustrate how superparamagnetic particles can be printed with very high loading efficiency (over 98 %) and single-particle resolution in the microwell array patterned in the Teflon-AF surface of the grounding plate of the chip.
View Article and Find Full Text PDFThe detection of single molecules in magnetic microbead microwell array formats revolutionized the development of digital bioassays. However, retrieval of individual magnetic beads from these arrays has not been realized until now despite having great potential for studying captured targets at the individual level. In this paper, optical tweezers were implemented on a digital microfluidic platform for accurate manipulation of single magnetic beads seeded in a microwell array.
View Article and Find Full Text PDFDigital microfluidics (DMF) has emerged as a promising liquid handling technology for a variety of applications, demonstrating great potential both in terms of miniaturization and automation. DMF is based on the manipulation of discrete, independently controllable liquid droplets, which makes it highly reconfigurable and reprogrammable. One of its most exclusive advantages, compared to microchannel-based microfluidics, is its ability to precisely handle solid nano- and microsized objects, such as magnetic particles.
View Article and Find Full Text PDFReliable, autonomous, internally self-powered microfluidic pumps are in critical demand for rapid point-of-care (POC) devices, integrated molecular-diagnostic platforms, and drug delivery systems. Here we report on a Self-powered Imbibing Microfluidic Pump by Liquid Encapsulation (SIMPLE), which is disposable, autonomous, easy to use and fabricate, robust, and cost efficient, as a solution for self-powered microfluidic POC devices. The imbibition pump introduces the working liquid which is sucked into a porous material (paper) upon activation.
View Article and Find Full Text PDFMagnetic Resonance (MR) microscopy is a noninvasive tool that enables high resolution imaging of water concentration in non-magnetic materials. In this study, water migration in a dense porous material (dental cement) was monitored by 1D MR microscopy. The measured concentration profiles were later analyzed via three different migration models: an imbibition model, a diffusion model and a combined model.
View Article and Find Full Text PDF