Publications by authors named "Tadashi Inaba"

Introduction: Although kissing spine syndrome in the lumbar spinal region is a relatively common condition in older adults, no study examining its biomechanical characteristics has been reported. We hypothesized that kissing of the spinous processes during extension causes an increase in the flexural rigidity of the spine and significantly limits the deformation behavior of extension, which in turn might cause lower back pain.

Methods: Three test models (human cadavers A, B, and C) were prepared by removing supraspinal/interspinous ligaments between L4 and L5.

View Article and Find Full Text PDF

Background Many studies have been conducted on the biomechanics of the spine to elucidate the fixation properties of spinal fusion surgery and the causes of instrumentation failure. Among these studies, there are some studies on load sharing in the spine and measurement using strain gauges and pressure gauges, but there is a lack of research on axial compressive loads. Methods Axial compressive load tests were performed on human cadaveric injured lumbar vertebrae fixed with pedicle screws (PS).

View Article and Find Full Text PDF

Aim: To assess biomechanical problems related to pedicle screw (PS) systems.

Material And Methods: Functional spinal units (L3-4) of deer were evaluated using a 6-axis material testing machine. For the specimen models, we prepared an intact model, a damaged model, a PS model, and a crosslink model.

View Article and Find Full Text PDF

BACKGROUND Surgery with pedicle screw instrumentation does not provide sufficient torsional stability. This leads to pseudoarthrosis, loosening of the pedicle screws, and, ultimately, implant failure. MATERIAL AND METHODS Functional spinal units from 18 deer were evaluated using a 6-axis material testing machine.

View Article and Find Full Text PDF

Background: Several studies showed instantaneous axis of rotation (IAR) in the intact spine. However, there has been no report on the trajectory of the IAR of a damaged spine or that of a fixed spine with instrumentation. It is the aim of this study to investigate the trajectory of the IAR of the lumbar spine using the vertebra of deer.

View Article and Find Full Text PDF

Study Design: Biomechanical study of double-level pedicle screw constructs with or without crosslinks (CL) in an unstable model.

Objectives: The purpose of this study is to investigate the optimal position and orientation of the CL.

Summary Of Background Data: Several reports have described biomechanical research on such CL, but no definite consensus has been reached regarding the effects.

View Article and Find Full Text PDF

OBJECTIVE To assess effects of vertebral distraction-fusion techniques at a treated segment (C5-C6) and an adjacent segment (C4-C5) of canine cervical vertebrae. SAMPLE Cervical vertebrae harvested from cadavers of 10 skeletally mature Beagles. PROCEDURES Three models (intact, titanium plate, and polymethylmethacrylate [PM MA]) for stabilization of the caudal region of the cervical vertebrae (C4 through C7) were applied to the C5-C6 vertebral segment sequentially on the same specimens.

View Article and Find Full Text PDF

Background: In regard to the fixation using a pedicle screw (PS) and rod system, the mechanism from the onset of the clear zone up to the development of loosening of the pedicle screw is not completely clarified. The purpose of this study is to determine the cause of the pedicle screw loosening by performing a biomechanical study with three-dimensional movie analysis.

Methods: Ten PS fixation model of the lumbar spines (L3-4) of boar cadavers were used.

View Article and Find Full Text PDF

Purpose: There have been several reports on the pullout strength of cortical bone trajectory (CBT) screws, but only one study has reviewed the stability of functional spine units using the CBT method. The purpose of this study was to compare vertebral stability after CBT fixation with that after pedicle screw (PS) fixation.

Methods: In this study, 20 lumbar spine (L5-6) specimens were assigned to two groups: the CBT model group that underwent CBT screw fixation (n = 10) and the PS model group that underwent pedicle screw fixation (n = 10).

View Article and Find Full Text PDF

Various biomechanical investigations have attempted to clarify the aetiology of adjacent segment disease (ASD). However, no biomechanical study has examined in detail the deformation behaviour of the adjacent segments when both pure torque and an angular displacement load are applied to the vertebrae along multiple segments. The purpose of this study is to investigate the biomechanical effects of pedicle screw fixation on adjacent segments.

View Article and Find Full Text PDF

The internal fixing materials made from shape-memory alloys (SMAs) have recently been reported for long bone fracture. We present a new internal fixation technique using a cylindrical SMAs implant in a rat femoral fracture healing. The implant was designed in a shape to circumferentially fix the fractured bone using resilient SMA claws.

View Article and Find Full Text PDF

Lumbar fusion combined with unilateral pedicle screw fixation has received favourable clinical reports. However, there are very few reports about the biomechanical properties of this system. The purpose of this study was to compare the biomechanics of a unilateral pedicle screw system with a bilateral system.

View Article and Find Full Text PDF

Background: Although low back pain can be principally produced or increased during action, it may also be induced or enhanced in the morning after bed rest. During bed rest, tissue edema (increased water content) may occur. In this study, we measured the changes in water content in the intervertebral disc and the paravertebral muscle before and after bed rest using a magnetization transfer magnetic resonance imaging (MT-MRI) technique that permits measuring water content in tissues.

View Article and Find Full Text PDF

We describe the development of a new device that permits handy intraoperative measurement of lumbar segmental instability. The subjects comprised 80 patients with lumbar degenerative disease. Relationships between preoperative radiological assessments and extended distance as measured using our new device were investigated.

View Article and Find Full Text PDF

Purpose: This study was undertaken to evaluate the changes in the radiopacity and mechanics of polymethylmethacrylate (PMMA) bone cement with the addition of barium.

Materials And Methods: Barium sulfate powder was added to a PMMA bone cement with an initial 10% barium concentration. The changes in radiopacity and strength were evaluated by testing cement blocks containing four barium concentrations (10%, 20%, 30%, 40%).

View Article and Find Full Text PDF

Background: There have been reports of serious complications associated with pedicle screw fixation, including nerve root injuries caused by accidental screw insertion. We have developed a new system of lumbar spinal instrumentation that we call Tadpole system. The purposes of this report were to show the results of a biomechanical study and the short-term outcome of a clinical study, as well as to determine the usefulness of this system.

View Article and Find Full Text PDF

Sentinel lymph node biopsy (SLNB) is an important technique for detecting axillary lymph node metastasis in breast carcinoma patients. However, false-negative results are a problem. Equivalent cross-relaxation rate (ECR) imaging (ECRI) is a measurement method that can be used to quantitatively evaluate a change in the structural organization of lymph nodes by magnetic resonance imaging (MRI).

View Article and Find Full Text PDF

In the breast carcinamas, sentinel lymph node biopsy (SLNB) attracts attention as technique to be settled by axillary lymph node metastasis, but existence of a false negative case is a problem. Equivalent cross relaxation rate image (ECRI) is the measurement method that we can evaluate a change of organization structure quantitatively by magnetic resonance imaging. We executed axillary ECRI as a purpose with decreasing a false negative case of SLNB.

View Article and Find Full Text PDF