Publications by authors named "Tachio Sato"

Unlabelled: We previously examined cerebral blood flow (CBF) with single-photon emission computed tomography (SPECT) in Alzheimer's disease (AD) with reference to drug treatment (donepezil) and psychosocial intervention.

Objective: The aim is to provide "brain-based" evidence for psychosocial interventions using SPECT.

Methods: The participants were 27 consecutive outpatients with AD who received the drug and psychosocial intervention, and SPECT three times (baseline, pre-/post-intervention) at 6 month-intervals.

View Article and Find Full Text PDF

Objective: Iodine-123 (123I)-labeled N-isopropyl-4-iodoamphetamine (IMP) has been used as a cerebral blood flow (CBF) tracer for single-photon emission computed tomography (SPECT). An autoradiographic (ARG) method has been developed for the quantitation of CBF by IMP and SPECT. Two IMPs (IMPA and IMPB) produced by different radiopharmaceutical companies are marketed in Japan.

View Article and Find Full Text PDF

Objectives: Three accumulative tracers, iodine-123-labeled N-isopropyl-p-iodoamphetamine (I-123-IMP), technetium-99m-labeled hexamethylpropyleneamineoxime (Tc-99m-HMPAO), and technetium-99m-labeled ethyl cysteinate dimer (Tc-99m-ECD) are widely used to measure cerebral blood flow (CBF) in single-photon emission computed tomography (SPECT). In the present study, normal regional distribution of CBF measured with three different SPECT tracers was entered into a database and compared with regional distribution of CBF measured by positron emission tomography (PET) with H2(15)O. The regional distribution of tissue fractions of gray matter determined by voxel-based morphometry was also compared with SPECT and PET CBF distributions.

View Article and Find Full Text PDF

Several studies using single photon emission tomography (SPECT) have shown changes in cerebral blood flow (CBF) with age, which were associated with partial volume effects by some authors. Some studies have also demonstrated gender-related differences in CBF. The present study aimed to examine age and gender effects on CBF SPECT images obtained using the 99mTc-ethyl cysteinate dimer and a SPECT scanner, before and after partial volume correction (PVC) using magnetic resonance (MR) imaging.

View Article and Find Full Text PDF

Objectives: Single-photon emission computed tomography (SPECT) with iodine-123 (123I)-labeled N-isopropyl-p-iodoamphetamine (IMP) is widely used in measuring the cerebral blood flow (CBF) response to acetazolamide stress for assessment of cerebral vascular reserve. To quantitate CBF by means of SPECT with IMP, an autoradiographic (ARG) method has been developed and is widely used. Because the relation between the brain counts on the SPECT scan and CBF is not linear in the ARG method, a mixture of gray and white matter in a pixel causes errors in the calculation of CBF.

View Article and Find Full Text PDF

Objectives: Iodine-123 (123I)-labeled N-isopropyl-p-iodoamphetamine (IMP) has been used as a cerebral blood flow (CBF) tracer for single-photon emission computed tomography (SPECT), and measurements of the CBF response to acetazolamide stress by SPECT with IMP are widely used to assess cerebral vascular reserve. To quantitate CBF by means of SPECT with IMP, an autoradiographic (ARG) method has been developed and is widely used. In the ARG method, CBF is calculated from the brain counts of the SPECT scan with an assumed distribution volume value of IMP (Vd).

View Article and Find Full Text PDF

A number of studies using single-photon emission tomography (SPET) have shown perfusion changes with age in several cortical and subcortical areas, which might distort the results of perfusion imaging studies of neuropsychiatric disorders. Technetium-99m labelled ethyl cysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO) are both used as markers of cerebral perfusion, but have different pharmacokinetics and retention patterns. The aim of this study was to determine whether age and gender effects on perfusion SPET differ depending on whether (99m)Tc-HMPAO or (99m)Tc-ECD is used.

View Article and Find Full Text PDF