Background: Wearable devices have been found effective in training ankle control in patients with neurological diseases. However, the neural mechanisms associated with using wearable devices for ankle training remain largely unexplored. This study aimed to investigate the ankle tracking performance and brain white matter changes associated with ankle tracking learning using a wearable-device system and the behavior-brain structure relationships in middle-aged and older adults.
View Article and Find Full Text PDFThe population loss rate of a honey bee colony is a critical index to verify its health condition. Forecasting models for the population loss rate of a honey bee colony can be an essential tool in honey bee health management and pave a way to early warning methods in the understanding of potential abnormalities affecting a honey bee colony. This work presents a forecasting and early warning algorithm for the population daily loss rate of honey bee colonies and determining warning levels based on the predictions.
View Article and Find Full Text PDFIn plant factories, plants are usually cultivated in nutrient solution under a controllable environment. Plant quality and growth are closely monitored and precisely controlled. For plant growth evaluation, plant weight is an important and commonly used indicator.
View Article and Find Full Text PDFThe intracellular ice formation (IIF) behavior of Haliotis diversicolor (small abalone) eggs is investigated in this study, in relation to controlling the cooling rate and the concentration of dimethyl sulfoxide (DMSO). The IIF phenomena are monitored under a self-developed thermoelectric cooling (TEC) cryomicroscope system which can achieve accurate temperature control without the use of liquid nitrogen. The accuracy of the isothermal and ramp control is within ±0.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
September 2013
In this paper, both hardware and software design to develop a wearable walking monitoring system for gait analysis are presented. For hardware, the mechanism proposed is adaptive to different individuals to wear, and the portability of the design makes it easy to perform outdoor experiments. Four force sensors and two angle displacement sensors were used to measure plantar force distribution and the angles of hip and knee joints.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2013
The EMG signal is a well-known and useful biomedical signal. Much information related to muscles and human motions is included in EMG signals. Many approaches have proposed various methods that tried to recognize human motion via EMG signals.
View Article and Find Full Text PDFWe herein introduce an automated three-dimensional (3D) locomotion tracking and pose reconstruction system for rodents with superior robustness, rapidity, reliability, resolution, simplicity, and cost. An off-the-shelf composite infrared (IR) range camera was adopted to grab high-resolution depth images (640×480×2048 pixels at 20Hz) in our system for automated behavior analysis. For the inherent 3D structure of the depth images, we developed a compact algorithm to reconstruct the locomotion and body behavior with superior temporal and solid spatial resolution.
View Article and Find Full Text PDFJ Opt Soc Am A Opt Image Sci Vis
April 2011
In this research we propose a fast and robust ellipse detection algorithm based on a multipass Hough transform and an image pyramid data structure. The algorithm starts with an exhaustive search on a low-resolution image in the image pyramid using elliptical Hough transform. Then the image resolution is iteratively increased while the candidate ellipses with higher resolution are updated at each step until the original image resolution is reached.
View Article and Find Full Text PDFMagn Reson Imaging
December 2009
Chemical shift imaging (CSI) relies on a strong and homogeneous main field. Field homogeneity ensures adequate coherence between the precessions of individual spins within each voxel. Variation of field strength between different voxels causes geometric distortion and intensity variation in chemical shift images, resulting in errors when analyzing the spatial distribution of specific chemical compounds.
View Article and Find Full Text PDF