Publications by authors named "T S Axelrod"

Cigarette smoking is considered to be a risk factor for several chronic diseases and even premature death. However, despite the importance of this detrimental habit, little seems known in terms of the overall toxicity potential of its ingredients in humans. In this study, a panel of genetically modified bioluminescent bioreporter bacteria was used to evaluate its usefulness in estimating the cigarette smoke's complex molecular mixture on a bacterial toxicity-bioreporter panel, both filtered or unfiltered.

View Article and Find Full Text PDF

The COVID-19 pandemic is a demonstration of an unforeseen event that disrupts normal life routine and greatly affects medical training. With its outbreak, clinical studies in medical schools were discontinued throughout the country, and the pre-clinical studies channeled into online learning, like all other university teaching activities. Since similar situations occurred in most western countries, a methodological approach of online teaching is required - principles, goals and implementation, with reference to the tension between the duty of care versus the duty of maintaining the clinician's and student's health.

View Article and Find Full Text PDF

The lateral flow immunoassay (LFIA) is the most successful point-of-care testing (POCT) method to date. In the case of clinical biomarkers that require quantification, it remains a challenge to quantitate those biomarkers using the lateral flow immunoassay remains a challenge due to the cost of the reader and possibly the type of marker used. In the present work, a new concept of a platform LFIA device configuration is proposed in which different, aligned membrane components, some already existing in the classical lateral flow immunoassay, and the others created with special new functions in the present device.

View Article and Find Full Text PDF

Background: Proper glenoid position in total shoulder arthroplasty (TSA) is important. However, traditional glenoid version (GV) measurements overestimate retroversion on radiographs (XR) and computed tomography (CT).The fulcrum axis (FA) uses palpable surface landmarks and may be useful as an intra-operative guide.

View Article and Find Full Text PDF

Integrating a dissolvable membrane into a sensor allows the control of sample flow, location and duration in critical areas. These time-barrier films stop the flow of samples until the membrane has dissolved, thus, for example, allowing increased exposure time between immunoreagents for the formation of greater numbers of immuno-complexes, ensuring higher sensitivity, reactivity, and helping to reduce false-positive signals. In this study, dissolvable polyvinyl alcohol (PVA) films are used in a 3D-printed sensor holder, which enables film integration without the use of glue.

View Article and Find Full Text PDF