Background: This study sought to evaluate the safety, efficacy, and resource utilization of a pilot outpatient surgery program for total hip arthroplasty compared to traditional inpatient total hip arthroplasty performed via the posterolateral approach.
Methods: A cohort of 68 patients from two sites were enrolled in a regional pilot project for outpatient total hip arthroplasty (THA) and matched 1:1 against a cohort of patients undergoing routine inpatient THA. Data was extracted retrospectively from patient and hospital charts including adverse events (AE), readmission within 90 days, emergency room (ER) visits, patient calls, patient-reported outcome measures, length of stay, and multiple surgical variables.
Aims: A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis.
Methods: Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component.
Aims: The primary aim of this trial was to compare the subsidence of two similar hydroxyapatite-coated titanium femoral components from different manufacturers. Secondary aims were to compare rotational migration (anteversion/retroversion and varus/valgus tilt) and patient-reported outcome measures between both femoral components.
Methods: Patients were randomized to receive one of the two femoral components (Avenir or Corail) during their primary total hip arthroplasty between August 2018 and September 2020.
Aims: Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design.
View Article and Find Full Text PDFBackground: Hemiarthroplasty is a common treatment for displaced femoral neck fractures, but limited Canadian data are available about hemiarthroplasty failure. We evaluated the frequency and predictors of hemiarthroplasty failure in Manitoba.
Methods: In this retrospective multicentre province-wide study, billing and joint registry databases showed 4693 patients who had hemiarthroplasty for treatment of femoral neck fracture in Manitoba over an 11-year period (2005-2015), including 155 hips with subsequent reoperations (open or closed) for treatment of hemiarthroplasty failure.