High concentrations of Cd (II) in wastewater have been reported several times which attracted top research attention to mitigate the pollution impacts of the contaminant. Therefore, this study aimed to develop a Zn-doped NiFeO pinecone biochar composite (ZNiF@PB) for the adsorption of Cd (II) from wastewater. FTIR confirmed immobilization of PB on the surface of ZNiF by the presence of C = O at 1638 cm, COOH at 1385 cm, C-O at 1009 cm and Fe-O at 756 cm.
View Article and Find Full Text PDFComplications accompanying photocatalyst stability and recombination of exciton charges in pollutants degradation has been addressed through the construction of heterojunctions, especially S-scheme heterojunction with strong and distinctive redox centres. Herein, an S-scheme BiOBr (BOR) and g-CNPO (CNPO) catalyst (BORCNPO) with oxygen vacancy (Ov) was synthesized for levofloxacin (LVX) and oxytetracycline (OTC) photodegradation under visible light. The 3D/3D BORCNPO catalyst possessed C-O-Br bridging bonds for efficient charge transfer during the fabrication of S-scheme heterojunction.
View Article and Find Full Text PDFA facile interconnected nanofibre electrode material derived from polybenzimidazol (PBI) was fabricated for a supercapacitor using a centrifugal spinning technique. The PBI solution in a mixture of dimethyl acetamide (DMA) and N, N-dimethylformamide (DMF) was electrospun to an interconnection of fine nanofibres. The as-prepared material was characterised by using various techniques, which include scanning electron microscopy (SEM), X-ray diffractometry (XRD), Raman, X-ray photoelectron spectroscopy (XPS), and Brunauer-Emmett-Teller (BET) among others.
View Article and Find Full Text PDFHigh concentration of chromium in aquatic environments is the trigger for researchers to remediate it from wastewater environments. However, conventional water treatment methods have not been satisfactory in removing chromium from water and wastewater over the last decade. Similarly, many adsorption studies have been focused on one aspect of the treatment, but this study dealt with all aspects of adsorption packages to come up with a concrete conclusion.
View Article and Find Full Text PDFA 5-day test duration makes BOD measurement unsatisfactory and hinders the development of a quick technique. Protein-like fluorescence peaks show a strong correlation between the BOD characteristics and the fluorescence intensities. For identifying and measuring BOD in surface water, a simultaneous absorbance-transmittance and fluorescence excitation-emission matrices (A-TEEM) method combined with PARAFAC (parallel factor) and PLS (partial least squares) analyses was developed using a tyrosine and tryptophan (tyr-trpt) mix as a surrogate analyte for BOD.
View Article and Find Full Text PDF