A 53-year-old woman with recurrent stomatitis, genital ulcers, and folliculitis was admitted to our hospital after experiencing visual disturbances for the past two weeks, and a non-throbbing headache for the past three days. She had also developed numbness in her left extremities. An ophthalmological examination revealed inflammatory changes in the eye.
View Article and Find Full Text PDFRev Sci Instrum
September 2023
A retroreflector array, composed of a cluster of small retroreflectors, is experimentally studied for application to a Michelson-type interferometer system in the fusion plasma experiment. Such a new-type reflector has the potential to be a vital and effective tool at a spatially limited location, such as on the vacuum chamber wall of plasma experimental devices. To investigate the effect of retroreflector array on the reflected beam properties, a tabletop experiment is performed with the retroreflector array composed of 4 mm corner-cube retroreflectors and with a 320-GHz (λ ∼ 0.
View Article and Find Full Text PDFA signal separation system is constructed on the multi-pass Thomson scattering system of Heliotron J to solve the problem of overlapping scattered light signals for the electron temperature anisotropy measurement. The phenomenon of overlapping scattered light signals is relieved by operating the signal separation system. A Raman scattering experiment is undertaken to verify the separation effect of the signal separation system.
View Article and Find Full Text PDFThis paper proposes a design of dual scattering angles multi-path Thomson scattering system with a signal separation function to solve the overlapping phenomenon of scattered light signals and to increase the measurement accuracy for the investigation of anisotropic electron velocity distribution. Furthermore, an optical path design is proposed to demonstrate how overlapping scattered light signals can be separated by setting the optical path in a limited room with a compact layout, which makes the incident interval between two overlapping scattered light signals 1.7 times longer than that of our current system.
View Article and Find Full Text PDFThe Pa line (1875.13 nm) in the near-infrared (NIR) region was evaluated to apply Stark broadening of the line spectrum to the electron density measurement of the small-pellet ablation cloud in Heliotron J, a medium-sized helical-axis heliotron device. Pa is three-to-four times broader than the visible H line (486.
View Article and Find Full Text PDF