J Synchrotron Radiat
November 2018
The combination of complementary techniques in the characterization of catalysts under working conditions is a very powerful tool for an accurate and in-depth comprehension of the system investigated. In particular, X-ray absorption spectroscopy (XAS) coupled with diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) and mass spectroscopy (MS) is a powerful combination since XAS characterizes the main elements of the catalytic system (selecting the absorption edge) and DRIFTS monitors surface adsorbates while MS enables product identification and quantification. In the present manuscript, a new reactor cell and an experimental setup optimized to perform time-resolved experiments on heterogeneous catalysts under working conditions are reported.
View Article and Find Full Text PDFThe European Synchrotron Radiation Facility has recently made available to the user community a facility totally dedicated to Time-resolved and Extreme-conditions X-ray Absorption Spectroscopy--TEXAS. Based on an upgrade of the former energy-dispersive XAS beamline ID24, it provides a unique experimental tool combining unprecedented brilliance (up to 10(14) photons s(-1) on a 4 µm × 4 µm FWHM spot) and detection speed for a full EXAFS spectrum (100 ps per spectrum). The science mission includes studies of processes down to the nanosecond timescale, and investigations of matter at extreme pressure (500 GPa), temperature (10000 K) and magnetic field (30 T).
View Article and Find Full Text PDFBM23 is the general-purpose EXAFS bending-magnet beamline at the ESRF, replacing the former BM29 beamline in the framework of the ESRF upgrade. Its mission is to serve the whole XAS user community by providing access to a basic service in addition to the many specialized instruments available at the ESRF. BM23 offers high signal-to-noise ratio EXAFS in a large energy range (5-75 keV), continuous energy scanning for quick-EXAFS on the second timescale and a micro-XAS station delivering a spot size of 4 µm × 4 µm FWHM.
View Article and Find Full Text PDFA new FReLoN (Fast-Readout Low-Noise) high-frame-rate detector adopted for the fast continuous collection of X-ray absorption spectra is presented. The detector is installed on the energy-dispersive X-ray absorption beamline ID24 at the ESRF and is capable of full time-resolved EXAFS spectra collection with over 4 kHz repetition rate and 0.2 ms exposure time.
View Article and Find Full Text PDFID29 is an ESRF undulator beamline with a routinely accessible energy range of between 20.0 keV and 6.0 keV (λ = 0.
View Article and Find Full Text PDF