Purpose: Unicompartmental knee arthroplasty (UKAs) are available in the market as fixed- and mobile-bearing (FB and MB) and can be characterised by a different set of design parameters in terms of geometries, materials and surgical approaches, with overall good clinical outcomes. However, clear biomechanical evidence concerning the consequences of variations of these features on knee biomechanics is still lacking; therefore, the present study aims to perform a sensitivity analysis to see which outcomes are affected by these variations.
Methods: For both MB-UKA and FB-UKA, five design and surgical parameters were defined (bearing insert thickness, tibial component material, implant components friction coefficient, antero-posterior slope angle and level of tibial bone resection).
Knee Surg Sports Traumatol Arthrosc
August 2024
Purpose: Patellofemoral pain, maltracking and instability remain common and challenging complications after total knee arthroplasty. Controversy exists regarding the effect of kinematic alignment on the patellofemoral joint, as it generally leads to more femoral component valgus and internal rotation compared to mechanical alignment. The aim of this systematic review is to thoroughly examine the influence of kinematic alignment on the third space.
View Article and Find Full Text PDFBackground: The objective of this study was to evaluate the correlation in measurements of the lower-limb coronal alignment between long-leg radiographs (LLRs) and computed tomography (CT) scanograms that were made during preoperative planning for robotic-arm-assisted knee arthroplasty. On the basis of published evidence demonstrating a good correlation between these imaging modalities in measuring the lower-limb mechanical axis, we hypothesized that there would be no significant differences between the 2 in the present study.
Methods: This multicenter cohort study across 3 tertiary centers included 300 patients undergoing primary robotic-arm-assisted total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA) for whom LLRs and CT scanograms were available preoperatively.
Purpose: The purpose of this study was to investigate the influence of increasing the tibial boundaries in functional alignment on femoral component orientation in total knee arthroplasty (TKA).
Methods: A retrospective review of a database of robotic-assisted TKAs using a digital joint tensioning device was performed (BalanceBot®; Corin). A total of 692 TKAs with correctable deformity were included.
Acta Orthop Belg
September 2023
Total knee arthroplasty (TKA) is a well-known surgical procedure performed to address end stage osteoarthritis. The main goal is to relieve pain, recover articular function and return to normal function as soon as possible. Over the years it is frequently performed in the elderly, but lately there is an increased demand in a younger and more active population.
View Article and Find Full Text PDF