Aims: The aim of this study was to create artificial intelligence (AI) software with the purpose of providing a second opinion to physicians to support distal radius fracture (DRF) detection, and to compare the accuracy of fracture detection of physicians with and without software support.
Methods: The dataset consisted of 26,121 anonymized anterior-posterior (AP) and lateral standard view radiographs of the wrist, with and without DRF. The convolutional neural network (CNN) model was trained to detect the presence of a DRF by comparing the radiographs containing a fracture to the inconspicuous ones.
Introduction: Over the past years, different fixation techniques focused on rotational stability in order to increase stability and stimulate union rates. Additionally, extracorporeal shockwave therapy (ESWT) has gained importance in the treatment of delayed and nonunions. Purpose of this study was to compare the radiological and clinical outcome of two headless compression screws (HCS) and plate fixation in scaphoid nonunions, in combination with intraoperative high energy ESWT.
View Article and Find Full Text PDFObjective: To evaluate the impact of immediate (first day after surgery) mobilization compared to standard five weeks cast immobilization on the functional outcome after volar locking plate fixation of distal radius fractures.
Design: Prospective randomized parallel group comparative trial.
Setting: Trauma Hospital, Austria.
Background: The aims of this study are to determine (i) SARS-CoV-2 antibody positive employees in Austrian trauma hospitals and rehabilitation facilities, (ii) number of active virus carriers (symptomatic and asymptomatic) during the study, (iii) antibody decline in seropositive subjects over a period of around 6 months, (iv) the usefulness of rapid antibody tests for outpatient screening.
Method: A total of 3301 employees in 11 Austrian trauma hospitals and rehabilitation facilities of the Austrian Social Insurance for Occupational Risks (AUVA) participated in this open uncontrolled prospective cohort study. Rapid lateral flow tests, detecting a combination of IgM and IgM against SARS-CoV-2), two different types of CLIA (Diasorin, Roche), RT-PCR tests and serum neutralization tests (SNTs) were performed.
Case Description: Osseointegration is a relatively new technique for prosthetic limb attachment that offers various improvements for patients with amputation and facilitates joint preservation. We present a case of implant loosening during rehabilitation in a patient with transtibial amputation that was successfully managed through a combination of measures, aiming to promote re-osseointegration of the implant.
Objectives: Not much is known about structured management of adverse events after osseointegration.