Publications by authors named "T F Fok"

This paper discusses the results of the micro-Raman analysis performed on paper-like graphene oxide (GO) samples consisting of many functionalised graphene layers and annealed at moderate temperatures (≤500 °C) under vacuum conditions (p ≃ 10 mbar). The analysis of the standalone samples revealed that the obtained material is characterised by a noticeable disorder level but still stays below the commonly accepted threshold of high or total disorder. GO formed in a simple way showed two spectral bands above 1650 cm recorded very rarely or not at all and their origin has been discussed in detail.

View Article and Find Full Text PDF

The development of the broad-bandwidth photon sources emitting in the soft X-ray range has attracted great attention for a long time due to the possible applications in high-resolution spectroscopy, nano-metrology, and material sciences. A high photon flux accompanied by a broad, smooth spectrum is favored for the applications such as near-edge X-ray absorption fine structure (NEXAFS), extended X-ray absorption fine structure (EXAFS), or XUV/X-ray coherence tomography (XCT). So far, either large-scale facilities or technologically challenging systems providing only limited photon flux in a single shot dominate the suitable sources.

View Article and Find Full Text PDF

The introduction of online motion synchronizing system on helical tomotherapy paves way for robust motion tracking. A recent upgrade launches modifications on both hardware and software of the kV tracking system. An evaluation on the kV subsystems, prior (Version1) and post upgrade (Version2), was performed to compare tracking accuracy by means of fiducial tracking error and resulted root-mean-square (RMS).

View Article and Find Full Text PDF

Purpose: The Synchrony tracking system of Radixact is capable of real-time tumor tracking by building a correlation model between external light-emitting diodes on the patient's chest and an internal marker. A phase shift between the chest wall and a lung tumor has been reported. Hence, this study focused on evaluating the accuracy of the tracking system, especially under a patient-specific breathing pattern with respiratory phase shifts.

View Article and Find Full Text PDF

A near 1-keV photons from the Xe/He plasma produced by the interaction of laser beam with a double stream gas puff target were employed for studies of L absorption edges of period 4 transitional metals with atomic number Z from 26 to 30. The dual-channel, compact NEXAFS system was employed for the acquisition of the absorption spectra. L absorption edges of the samples were identified in transmission mode using broadband emission from the Xe/He plasma to show the applicability of such source and measurement system to the NEXAFS studies of the transition metals, including magnetic materials.

View Article and Find Full Text PDF