Publications by authors named "Szu-Wei Chou"

Article Synopsis
  • - The study addresses the limitations of traditional mass spectrometry (MS) for intact protein analysis, particularly due to large protein sizes and slow ion flight speeds which lead to low sensitivity and resolution.
  • - A new compact ion trap-mass spectrometry method is proposed to enhance the detection of protein ions, utilizing a specially designed radio frequency waveform to minimize ion motion disturbances and improve spectral quality.
  • - This method successfully measured cytochrome C proteins with a resolution of 20 Da and demonstrated quick scanning capabilities for other proteins, showcasing its potential for high-resolution protein analysis.
View Article and Find Full Text PDF

Detecting megadalton matrix-assisted laser desorption/ionization (MALDI) ions in an ion trap mass spectrometer is a technical challenge. In this study, megadalton protein and polymer ions were successfully measured by MALDI linear ion trap mass spectrometer (LIT-MS) for the first time. The LIT-MS is comprised of a Thermo linear ion trap mass analyzer and a highly sensitive charge-sensing particle detector (CSPD).

View Article and Find Full Text PDF

A laser-induced rf plasma (LIRFP) ion source was developed to ionize submicrometer-sized particles for the first time. The LIRFP ion source can increase the charge of those particles to several thousand charges via charge exchange reactions so that those particles can be trapped and analyzed with a charge detection quadrupole ion trap-mass spectrometer (CD QIT-MS). Different reagent gases for charge exchange reaction were investigated, viz.

View Article and Find Full Text PDF

Conventional linear ion trap mass analyzers (LIT-MS) provide high ion capacity and show their MS ability; however, the detection of high mass ions is still challenging because LIT-MS with secondary electron detectors (SED) cannot detect high mass ions. To detect high mass ions, we coupled a charge detector (CD) to a rectilinear ion trap mass spectrometer (RIT-MS). Immunoglobulin G ions (m/z ~150,000) are measured successfully with controlled ion kinetic energy.

View Article and Find Full Text PDF

Large biomolecules and bioparticles play a vital role in biology, chemistry, biomedical science and physics. Mass is a critical parameter for the characterization of large biomolecules and bioparticles. To achieve mass analysis, choosing a suitable ion source is the first step and the instruments for detecting ions, mass analyzers and detectors should also be considered.

View Article and Find Full Text PDF

We adopt an orthogonal wavelet packet decomposition (OWPD) filtering approach to cancel harmonic interference noises arising from an AC power source in time domain and remove the resulting rf voltage interference noise from the mass spectra acquired by using a charge detection frequency-scan quadrupole ion trap mass spectrometer. With the use of a phase lock resampling technique, the transform coefficients of the rf interference in signals become a constant, exhibiting a shift of the baseline in different rf phases. The rf interference is therefore removable by shifting the baselines back to zero in OWPD coefficients.

View Article and Find Full Text PDF