Article Synopsis
  • This study examines how environmental factors, like lighting and wall color, affect image quality in mammography quality assurance processes.
  • Nine test images were analyzed under various conditions, revealing that wall color and illumination significantly influence the visibility of structures in the images.
  • Results recommend using grey wall colors and low lighting to enhance image visibility, suggesting a need for standardizing these factors in breast imaging rooms for better quality control.
View Article and Find Full Text PDF

Introduction: Patients receiving end-of-life care often undergo medical imaging examinations in hospitals to inform symptom management and care. Yet little is known about the experiences of the radiography workforce who deliver it. This study aims to describe and explore experiences of the UK radiography workforce delivering medical imaging as part of patients' end-of-life care.

View Article and Find Full Text PDF

Introduction: Acceptance of new technologies in health care, by those who use them as part of their role, is challenging with confounding contextual factors surrounding the acceptance of technology. As healthcare is rapidly digitising, stakeholder groups should be included in each stage of evaluation and implementation to allow opportunities to influence and contribute to digital health policies. This research employed a case study methodology to initiate an exploration into the factors associated with implementing a digital application into a mammography service.

View Article and Find Full Text PDF

Introduction: People nearing the end of life often require medical imaging in hospitals to manage symptoms and care, despite this little is known about the experiences of those delivering it. The aim of this study is therefore to explore the experiences of the radiography workforce delivering medical imaging as part of patients' end-of-life care.

Method: Qualitative design using semi-structured interviews and thematic analysis.

View Article and Find Full Text PDF

Skin tears are classed as traumatic wounds mainly caused by shearing and frictional forces. Incidences of skin tears are noted to be significant mostly in the elderly population and those with fragile and vulnerable skin. Individuals undergoing mammography are susceptible to skin tears due to factors associated with skin breakdown such as thinning of the epidermis, use of steroids, presence of moisture, but this, when compounded with the procedure of mammography can increase the risk further.

View Article and Find Full Text PDF

Introduction: Pain and discomfort has a negative impact on a patient's overall experience and may impact on subsequent re-attendance to mammography. Pain during mammography remains a significant issue. Assessment of interventions to reduce levels of pain associated with mammography are essential to increase attendance to breast services and improve user experience.

View Article and Find Full Text PDF

Introduction: Hydatidiform moles are the most common type of gestational trophoblastic disease. Internationally the incidence of hydatidiform moles is 1-2:1000 pregnancies. Early detection of women with hydatidiform moles is preferential, as these women are at a higher risk of developing other gestational trophoblastic disease.

View Article and Find Full Text PDF

Introduction: Pressure ulcers present significant trauma to patients and are expensive to manage. In medical imaging (MI), no study has been conducted to rigorously investigate interface pressure (IP) risk on MI table surfaces. IP is defined as the pressure between human body and a supporting surface.

View Article and Find Full Text PDF

Purpose: Two types of CT images (modalities) are acquired in PET/CT: for attenuation correction (AC) and diagnosis. The purpose of the study was to compare nodule detection and localization performance between these two modalities.

Methods: CT images, using both modalities, of an anthropomorphic chest phantom containing zero or more simulated spherical nodules of 5, 8, 10 and 12 mm diameters and contrasts -800, -630 and 100 HU were acquired.

View Article and Find Full Text PDF

Introduction: Effective dose (ED) estimation in CT examinations can be obtained by combining dose length product (DLP) with published ED per DLP coefficients or performed using software. These methods do not account for tube current (mA) modulation which is influenced by patient size. The aim of the work was to compare different methods of organ and ED estimation to measured values when using mA modulation in CT chest, abdomen and pelvis examinations.

View Article and Find Full Text PDF

Purpose: Planar bone scans play an important role in the staging and monitoring of malignancy and metastases. Metastases in the lumbar spine are associated with significant morbidity; therefore, accurate diagnosis is essential. Supplementary imaging after planar bone scans is often required to characterize lesions; however, this is associated with additional radiation dose.

View Article and Find Full Text PDF

Purpose: To evaluate nodule detection in an anthropomorphic chest phantom in computed tomography (CT) images reconstructed with adaptive iterative dose reduction 3D (AIDR(3D)) and filtered back projection (FBP) over a range of tube current-time product (mAs).

Methods: Two phantoms were used in this study: (i) an anthropomorphic chest phantom was loaded with spherical simulated nodules of 5, 8, 10, and 12 mm in diameter and +100, -630, and -800 Hounsfield units electron density; this would generate CT images for the observer study; (ii) a whole-body dosimetry verification phantom was used to ultimately estimate effective dose and risk according to the model of the BEIR VII committee. Both phantoms were scanned over a mAs range (10, 20, 30, and 40), while all other acquisition parameters remained constant.

View Article and Find Full Text PDF

Objective: To measure the organ dose and calculate effective dose from CT attenuation correction (CTAC) acquisitions from four commonly used gamma camera single photon emission CT/CT systems.

Methods: CTAC dosimetry data was collected using thermoluminescent dosemeters on GE Healthcare's Infinia™ Hawkeye™ (GE Healthcare, Buckinghamshire, UK) four- and single-slice systems, Siemens Symbia™ T6 (Siemens Healthcare, Erlangen, Germany) and the Philips Precedence (Philips Healthcare, Amsterdam, Netherlands). Organ and effective dose from the administration of (99m)Tc-tetrofosmin and (99m)Tc-sestamibi were calculated using International Commission of Radiological Protection reports 80 and 106.

View Article and Find Full Text PDF

Rationale And Objectives: The purpose of this study was to compare lesion-detection performance when interpreting computed tomography (CT) images that are acquired for attenuation correction when performing single photon emission computed tomography/computed tomography (SPECT/CT) myocardial perfusion studies. In the United Kingdom, there is a requirement that these images be interpreted; thus, it is necessary to understand observer performance on these images.

Materials And Methods: An anthropomorphic chest phantom with inserted spherical lesions of different sizes and contrasts was scanned on five different SPECT/CT systems using site-specific CT protocols for SPECT/CT myocardial perfusion imaging.

View Article and Find Full Text PDF

Purpose: Compression is necessary in mammography to improve image quality and reduce radiation burden. Maximizing the amount of breast in contact with the image receptor (IR) is important. To achieve this, for the craniocaudal projection, there is no consensus within the literature regarding how the IR should be positioned relative to the inframammary fold (IMF).

View Article and Find Full Text PDF

Objective: To perform a calibration study to provide data to help improve consistency in the pressure that is applied during mammography.

Methods: Automatic readouts of breast thickness accuracy vary between mammography machines; therefore, one machine was selected for calibration. 250 randomly selected patients were invited to participate; 235 agreed, and 940 compression data sets were recorded (breast thickness, breast density and pressure).

View Article and Find Full Text PDF

ROCView has been developed as an image display and response capture (IDRC) solution to image display and consistent recording of reader responses in relation to the free-response receiver operating characteristic paradigm. A web-based solution to IDRC for observer response studies allows observations to be completed from any location, assuming that display performance and viewing conditions are consistent with the study being completed. The simplistic functionality of the software allows observations to be completed without supervision.

View Article and Find Full Text PDF

Purpose: To establish a simple method to determine breast readout accuracy on mammography units.

Methods: A thickness measuring device (TMD) was used in conjunction with a breast phantom. This phantom had compression characteristics similar to human female breast tissue.

View Article and Find Full Text PDF

Objective: To quantify neutrophil migration into the lungs of patients with chronic pulmonary obstructive disease (COPD).

Methods: Neutrophil loss via airways was assessed by dedicated whole-body counting 45 min, 24 h and 2, 4, 7 and 10 days after injection of very small activities of (111)In-labelled neutrophils in 12 healthy nonsmokers, 5 healthy smokers, 16 patients with COPD (of whom 7 were ex-smokers) and 10 patients with bronchiectasis. Lung accumulation of (99m)Tc-labelled neutrophils was assessed by sequential SPECT and Patlak analysis in six COPD patients and three healthy nonsmoking subjects.

View Article and Find Full Text PDF

Background: There is increasing interest in the 'homing' of neutrophils to bone marrow. The aim of this study was to measure the whole-body redistribution of (111) In using a whole-body counter following the administration of ultra-small activities of (111) In-labelled neutrophils.

Methods: The detectors of a dedicated whole-body counter were fitted with lead collimators.

View Article and Find Full Text PDF

Objective: The clearance rate of inhaled 99mTc-sestamibi from the lungs of healthy nonsmoking individuals is much slower than would be expected from its physical properties. The clearance rate is even slower in healthy cigarette smokers. As 99mTc-sestamibi is a substrate for P-glycoprotein (P-gp), pulmonary P-gp may be influential in 99mTc-sestamibi clearance and may be upregulated in smokers.

View Article and Find Full Text PDF

What Is Already Known About This Subject: * Very little is known about the physiology of P-glycoprotein (P-gp) expression in the lungs. * Ex vivo evidence based on resected lung tissue suggests that pulmonary P-gp is upregulated by cigarette smoke, but there are no in vivo studies to date.

What This Study Adds: * The novel observation that healthy cigarette smokers have a delayed pulmonary elimination rate of inhaled (99m)Tc-sestamibi, a P-gp substrate, provides for the first time a potential method for quantifying functional pulmonary P-gp expression that may inform about drug therapy by inhalation as well as provide a non-invasive, quantitative, human biomarker for assessing P-gp modulators.

View Article and Find Full Text PDF

Question: Does passive smoking have a measurable effect on lung function in otherwise healthy subjects? There is current interest concerning passive smoking but no objective evidence showing that it has any impact on lung function.

Methods: The pulmonary clearance rate of (99m)Tc-DTPA was measured in 21 healthy volunteers after inhalation as a radio-aerosol and compared between healthy cigarette smokers, passive smokers and non-smokers. All volunteers had normal lung function.

View Article and Find Full Text PDF