All major ear rots (, , and ) and their toxins are present in maize of preharvest origin in Hungary. Resistance can be an important tool in reducing the infection and toxin contamination from these rots in maize. Previous results identified resistance differences in maize hybrids that were suitable for use in evaluating their risk from toxigenic fungi and their toxins.
View Article and Find Full Text PDFCertain soil insects, such as the root-damaging larvae of the maize pest (Coleoptera: Chrysomelidae), are increasingly difficult to control because of recent bans of some insecticides. An alternative and safer approach may be the development of biopesticides based on entomotoxic defense proteins of higher fungi. Many of these potentially interesting proteins are protease inhibitors, and some have been shown to adversely affect insects.
View Article and Find Full Text PDFWe report on an optical architecture delivering sub-120 femtosecond laser pulses of 20 µJ tunable from 5.5 µm to 13 µm in the mid-infrared range (mid-IR). The system is based on a dual-band frequency domain optical parametric amplifier (FOPA) optically pumped by a Ti:Sapphire laser and amplifying 2 synchronized femtosecond pulses each with a widely tunable wavelength around 1.
View Article and Find Full Text PDFThe western corn rootworm (WCR) Diabrotica virgifera virgifera (Coleoptera: Chrysomelidae) remains one of the economically most important pests of maize (Zea mays) due to its adaptive capabilities to pest management options. This includes the ability to develop resistance to some of the commercial pesticidal proteins originating from different strains of Bacillus thuringiensis. Although urgently needed, the discovery of new, environmentally safe agents with new modes of action is a challenge.
View Article and Find Full Text PDFPost-compression of 12-fs laser pulses with multi-TW peak power from an optical parametric chirped pulse amplification (OPCPA) system was performed by using a single thin fused silica plate in a vacuum. By optimizing the input pulses in both spatial and temporal domains, after compression with customized chirped mirrors, we achieved pulses as short as 3.87 fs, in combination with 12-mJ energy.
View Article and Find Full Text PDFBackground: Organization of mass sport events in the COVID-19 era is utterly complicated. Containments measures, required to avoid a virus outbreak, force athletes to compete under circumstances they never experienced before, most likely having a deleterious effect on their performance.
Purpose: We aimed to design a so-called athlete-friendly bubble system for the International Swimming League 2020 event, which is strict enough to avoid a COVID-19 outbreak, but still provides a supportive environment for the athletes.
The calibration of an ion detection system was carried out for protons and carbon ions from a few tens of keV up to about 1 MeV energies. A Thomson spectrometer deflecting the particle beam accelerated from a laser plasma creates the ion spectra on a phosphor screen behind a micro-channel plate (MCP), which are recorded by a camera. During calibration, the ion spectra simultaneously hit the slotted CR-39 track detector installed in front of the MCP and, passing through the adjacent CR-39 stripes, the MCP.
View Article and Find Full Text PDFDuring liver transplantation, haemostasis is typically assessed by means of standard laboratory tests and viscoelastic tests, while dynamic monitoring of coagulation factor specific blood losses is an unusual, yet established approach. Our aim was to evaluate the volume-based haemostasis reserves in blood product free liver transplants in the first perioperative 48 hours, in association with the Child-Pugh score. Data of 59 blood product free liver transplanted patients' coagulation factor levels, viscoelastic parameters and coagulation factor specific blood losses according to Gross methodological, baseline and 'coagulopathic' trigger levels were analysed.
View Article and Find Full Text PDFIn the last decades, the results of liver transplantation have shown significant improvement. More patients are eligible for liver transplantation, while the indications are changing. The worldwide shortage of donor organs urges the profession for the development of new strategies.
View Article and Find Full Text PDFThis paper presents a single-shot technique for measuring CEP. The Temporal dispersion based One-shot Ultrafast Carrier envelope phase Analysis method (TOUCAN) is an arbitrary repetition rate single-shot CEP drift measurement technique based on dispersive Fourier transformations and has been experimentally tested at 100 kHz. TOUCAN was validated by a direct comparison of decimated data with an independent traditional CEP drift measurement technique.
View Article and Find Full Text PDFMachine perfusion of marginal grafts might be a possible solution to organ shortage and a promising tool for reducing waiting list morbidity and mortality. In recent years, optimizing the circumstances of organ preservation prior to implantation via machine perfusion has become a hot topic of research. Machine perfusion offers a platform for organ reconditioning, assessment of cell viability and function, pharmacological preconditioning, prolongation of preservation time (ischemia time) and finally reducing graft injury.
View Article and Find Full Text PDFThe scheme of cascaded extraction optical parametric amplifier (CE-OPA) has been proposed as a final amplifier for high peak power laser systems. 4D numerical simulations show that conversion efficiency of a CE-OPA system pumped with a temporal Gaussian pump pulse is as close to the theoretical limit of quantum efficiency as a conventional OPA pumped with temporal flat-top pump pulse. The CE-OPA system is also similar to the conventional scheme in output energy stability and alignment sensitivity of the phase-matching angles, too.
View Article and Find Full Text PDFpCAMBIA vectors have become popular for their easy handling, stability and the existence of a range of selection and reporter genes. However, these vectors have yet to integrate the Gateway® cloning system, which has enabled site-specific recombination without the need for restriction enzymes and ligases. This paper sets out to convert the pCambia2300 binary vector into a destination vector with the Gateway® cassette driven by the CaMV35S promoter.
View Article and Find Full Text PDFBesides orthotopic liver transplantation (OLT) there is no long-term and effective replacement therapy for severe liver failure. Artificial extracorporeal liver supply devices are able to reduce blood toxin levels, but do not replace any synthetic function of the liver. Molecular adsorbent recirculating system (MARS) is one of the methods that can be used to treat fulminant acute liver failure (ALF) or acute on chronic liver failure (AoCLF).
View Article and Find Full Text PDFUnlabelled: Liver transplantation is a routinely used therapeutic choice in the treatment of end stage liver disease. Portal vein stenosis is a rare vascular complication after liver transplantation. We report the interventional radiological management of three cases of portal vein stenosis.
View Article and Find Full Text PDFBecause of the long waiting time for pediatric liver transplantation, new techniques of liver transplantation were invented. Split and living-donor related liver transplantation are common today and the Kaplan-Meier (3 years) overall survival is over 80%. By splitting the liver, two recipients can be transplanted.
View Article and Find Full Text PDFIntroduction: The authors summarize the characteristics of biliary complications following liver transplantation in the Hungarian liver transplant program. Aims were to analyze the frequency and the types of biliary complications as well as their effect on the patient and graft survival. The authors observed the known risk factors in the Hungarian practice, and they also try to find unknown risk factors for biliary complications.
View Article and Find Full Text PDFUnlabelled: Liver resection is the curative therapeutic option for hepatocellular carcinoma, biliary tumors, metastases of colorectal and other extrahepatic tumors, living donor liver transplantation and other benign liver diseases.
Aim Of Study: To summarize the evaluation methods of liver function before living donor liver transplantation and liver resection.
Method: We summarize the literature about the evaluation of liver function.
The living related donor mortality after liver donation could occur as a result of postoperative cardiovascular and thromboembolic complication; which could be minimized by detailed preoperative assessment of the living donor. The preoperative functional tests evaluate the physiological reserve or identify the living donors with limited response to the surgical stress. Based on the results of CT volumetry, MRI and liver functional reserve capacity test (indocyanine green retention ratio) the liver resection can be done safely.
View Article and Find Full Text PDFIt is generally assumed that the developmental program of embryogenesis relies on epigenetic mechanisms. However, a mechanistic link between epigenetic marks and cell fate decisions had not been established so far. In a recent article, Torres-Padilla and colleagues show that epigenetic information and, more precisely, histone arginine methylation mediated by CARM1 could contribute to cell fate decisions in the mouse 4-cell-stage embryo.
View Article and Find Full Text PDFThe Ca2+ oscillations initiated by the fertilizing sperm (but terminating concomitant with pronucleus formation) apparently ensure that the events constituting egg activation occur in the correct temporal order; early events (e.g., cortical granule exocytosis) require fewer oscillations than later events (e.
View Article and Find Full Text PDFEgg activation in mammals is caused by cytosolic Ca(2+) oscillations that are essential for development. However, despite increasing knowledge about signal transduction mechanisms, the functional linkage between frequency number, amplitude and duration of the Ca(2+) signal and the kinetics of pronucleus formation has not yet been defined. While a wide range of Ca(2+) signal parameters are efficient in causing egg activation, the basic rules governing how the egg integrates these signalling events are not yet clear.
View Article and Find Full Text PDFBackground: The low-pressure water dissection technique of Toth, first reported in 1987, is a method to cautiously open neurosurgical cleavage planes such as the sylvian fissure or the interhemispheric space, and the interfaces between extraparenchymal masses and the adjacent brain. The aim of this technical report is to present our long-term experience with this simple and elegant asset of microneurosurgery and to promote its widespread use.
Method: Water is injected under microscopic control by a hand-held syringe with a blunt needle or by an irrigating balloon applying repeated injections of physiological saline into the cleavage plane to open it.
Although the dynamics of oscillations of cytosolic Ca2+ concentration ([Ca2+]cyt) play important roles in early mammalian development, the impact of the duration when [Ca2+]cyt is elevated is not known. To determine the sensitivity of fertilization-associated responses [i.e.
View Article and Find Full Text PDFIn the past decade, owing to the advance of epilepsy surgery, growing knowledge has accumulated on the role of the supplementary motor area, described by Penfield and coworkers in the early fifties, in movement regulation and on the characteristics of seizures involving this area. In the Hungarian neurological literature this topic--despite its neurophysiological and practical clinical importance--has been hardly touched. The authors, based on their own experience obtained from surgeries performed within the framework of the "Co-operative Epilepsy Surgery Program", describe the electrophysiological features of this area, its role in movement regulation and the symptoms of epileptic seizures stemmed from or spread onto this area.
View Article and Find Full Text PDF