Using rotors to expose animals to different levels of hypergravity is an efficient means of understanding how altered gravity affects physiological functions, interactions between physiological systems and animal development. Furthermore, rotors can be used to prepare space experiments, e.g.
View Article and Find Full Text PDFBackground: Short periods of fasting and/or low-carbohydrate diet have been proven beneficial for decreasing the myocardial uptake of F-fluorodeoxyglucose (F-FDG) and enhancing the detection of inflammatory heart diseases by F-FDG positron emission tomography (PET). This study aimed at determining whether this benefit is increased when a low-carbohydrate ketogenic diet is prolonged up to 7 days.
Methods: Wistar rats underwent serial F-FDG-PET imaging after an 18-hour fasting period and after 2, 4 and 7 days of a ketogenic diet (3% carbohydrate) and they were compared to rats submitted to the same protocol but with normal diet (44% carbohydrate).
Purpose: 6-[F]fluoro-L-DOPA ([F]FDOPA), a positron emission tomography (PET) amino-acid tracer of brain decarboxylase activity, is used to assess the brain dopaminergic system. Using a voxel-based semi-quantitative analysis, this study aimed to determine whether a current brain uptake index of [F]FDOPA, expressed relative to the occipital background level, varies according to age and gender.
Procedures: One hundred and seventy-seven subjects were retrospectively included.
Background: Tracers triggering αvβ3 integrins, such as certain RGD-containing peptides, were found promising in previous pilot studies characterizing high-grade gliomas. However, only limited comparisons have been performed with current PET tracers. This study aimed at comparing the biodistribution of F-fluorodeoxyglucose (F-FDG) with that of Ga-NODAGA-RGD, an easily synthesized monomeric RGD compound with rapid kinetics, in two different rodent models of engrafted human glioblastoma.
View Article and Find Full Text PDFBackground: The mismatch between traditional in vitro cell culture conditions and targeted chronic hypoxic myocardial tissue could potentially hamper the therapeutic effects of implanted bone marrow mesenchymal stem cells (BMSCs). This study sought to address (i) the extent of change to BMSC biological characteristics in different in vitro culture conditions and (ii) the effectiveness of permanent hypoxic culture for cell therapy in treating chronic myocardial infarction (MI) in rats.
Methods: rat BMSCs were harvested and cultured in normoxic (21% O2, n=27) or hypoxic conditions (5% O2, n=27) until Passage 4 (P4).
This study describes the synthesis and radiosynthesis of eight new [F]fluoro-inositol-based radiotracers in myo- and scyllo-inositol configuration. These radiotracers are equipped with a propyl linker bearing fluorine-18. This fluorinated arm is either on a hydroxyl group, i.
View Article and Find Full Text PDFPurpose: The Statistical Parametric Mapping (SPM) software is frequently used for the quantitative analysis of patients' brain images obtained from 2-deoxy-2-[F]fluoro-D-glucose positron emission tomography ([F]FDG PET). However, its adaptation to small animals is difficult, particularly for the initial step of spatial normalization which requires a specific brain anatomical template. This study was aimed at determining whether SPM analysis can be applied to rat, and more specifically to the lithium-pilocarpine model of epilepsy, by using an adaptive template.
View Article and Find Full Text PDFPurpose: Gamma-cameras, with Cadmium-Zinc-Telluride (CZT) detectors, allow to perform myocardial perfusion imaging (MPI) with limited injected activities and recorded times. This study aimed at determining whether the routine assessment of left ventricular (LV) function with such limited counts protocols compares well with reference values from cardiac MRI.
Methods: The study included patients who have undergone cardiac MRI and an MPI routinely planned on a CZT camera with a low-dose protocol (120 MBq of Sestamibi for stress and 360 MBq at rest for 75 kg body weight), while targeting the recording of only 500 myocardial kcounts in order to limit the recording times (<10 minutes for stress, <4 minutes for rest).
Introduction: Statistical parametric mapping (SPM) provides useful voxel-by-voxel analyses of brain images from (18)F-fluorodesoxyglucose positron emission tomography (FDG-PET) after an initial step of spatial normalization through an anatomical template model. In the setting of the preoperative workup of patients with temporal epilepsy, this study aimed at assessing a block-matching (BM) normalization method, where most transformations are computed through small blocks, a principle that minimizes artefacts and overcomes additional image-filtering.
Methods: Brain FDG-PET images from 31 patients with well-characterised temporal lobe epilepsy and among whom 22 had common mesial temporal lobe epilepsy were retrospectively analysed using both BM and conventional SPM normalization methods and with PET images from age-adjusted controls.
This work describes the development of new 6-[(18) F]fluoro-carbohydrate-based prosthetic groups equipped with an azido arm that are able to participate in copper(I)-catalyzed cycloadditions for (18) F labeling of biomolecules under mild conditions. The radiolabeling in high radiochemical yields (up to 68 ± 6%) of these different prosthetic groups is presented. The flexibility of the azido arm introduced on the carbohydrate moieties allows efficient click reactions with different alkyne functionalized peptides such as gluthation or Arg-Gly-Asp derivatives in order to prepare glycopeptides.
View Article and Find Full Text PDFIntroduction: The impact of age is crucial and must be taken into account when applying a voxel-based quantitative analysis on brain images from [¹⁸F]-fluorodeoxyglucose Positron Emission Tomography (FDG-PET). This study aimed to determine whether age-related changes in brain FDG-PET images are more accurately assessed when the conventional statistical parametric mapping (SPM) normalization method is used with an adaptive template, obtained from analysed PET images using a Block-Matching (BM) algorithm to fit with the characteristics of these images.
Methods: Age-related changes in FDG-PET images were computed with linear models in 84 neurologically healthy subjects (35 women, 19 to 82-year-old), and compared between results provided by the SPM normalization algorithm applied on its dedicated conventional template or on the adaptive BM template.
Purpose: Effective doses of 14 mSv or higher are currently being attained in patients having stress and rest myocardial perfusion imaging (MPI) single photon emission computed tomography (SPECT) performed on the same day with conventional protocols. This study aimed to assess the actual reduction in effective doses as well as diagnostic performances for MPI routinely planned with: (1) high-sensitivity cadmium zinc telluride (CZT) cameras, (2) very low injected activities and (3) a stress-first protocol where the normality of stress images may lead to avoiding rest imaging.
Methods: During a 1-year period, 2,845 patients had MPI on a CZT camera, a single-day stress-first protocol and low injected activities (120 MBq of (99m)Tc-sestamibi at stress for 75 kg body weight and threefold higher at rest).
Geant4 application for tomographic emission (GATE), a Monte-Carlo simulation platform, has previously been used for optimizing tomoscintigraphic images recorded with scintillation Anger cameras but not with the new-generation heart-centric cadmium-zinc-telluride (CZT) cameras. Using the GATE platform, this study aimed at simulating the SPECT recordings from one of these new CZT cameras and to assess this simulation by direct comparison between simulated and actual recorded data, ranging from point sources to human images. Geometry and movement of detectors, as well as their respective energy responses, were modeled for the CZT 'D.
View Article and Find Full Text PDFBackground: 18F-FDG PET can be used to aid in the diagnosis of Alzheimer's disease (AD) and clarify the diagnosis and prognosis of patients with mild cognitive impairment (MCI).
Purpose: To compare the results of a quantitative analysis of FDG-PET brain images to a standard visual analysis (SVA) with regards to the detection of MCI-like hypometabolic pattern in elderly patients with hypertension and subjective, isolated memory complaints.
Material And Methods: FDG-PET brain was performed in 71 patients (mean age, 76.
Spontaneously hypertensive heart failure rats (SHHF) appear to constitute an original model for analyzing the evolution of the metabolic syndrome towards heart failure. This study aimed to characterize early cardiac dysfunction and remodeling in SHHF rats: (1) as compared with spontaneously hypertensive rats (SHR) and with a control group of Kyoto rats (WKY), and (2) by using the 3-dimensional quantitative analysis provided by acipimox-enhanced positron emission tomography (PET) with (18)F-fluorodesoxyglucose (FDG). Left ventricular (LV) ejection fraction (EF) and volume were quantified by automatic software on the FDG-PET images recorded in SHR (n = 20), SHHF (n = 18) and WKY-rats (n = 19) at ages 3 or 10 months old.
View Article and Find Full Text PDFPurpose: Injected doses are difficult to optimize for exercise SPECT since they depend on the myocardial fraction of injected activity (MFI) that is detected by the camera. The aim of this study was to analyse the factors affecting MFI determined using a cardiac CZT camera as compared with those determined using conventional Anger cameras.
Methods: Factors affecting MFI were determined and compared in patients who had consecutive exercise SPECT acquisitions with (201)Tl (84 patients) or (99m)Tc-sestamibi (87 patients) with an Anger or a CZT camera.
Background: Adenosine may have beneficial effects on left ventricular function after myocardial infarction (MI), but the magnitude of this effect on remote and MI areas is controversial. We assessed the long-term effects of adenosine after MI using electrocardiogram-triggered 18 F-fluorodeoxyglucose positron emission tomography.
Methods: Wistar rats were subjected to coronary ligation and randomized into three groups treated daily for 2 months by NaCl (control; n = 7), 2-chloroadenosine (CADO; n = 8) or CADO with 8-sulfophenyltheophilline, an antagonist of adenosine receptors (8-SPT; n = 8).
This study aimed at comparing long-term variations in the perfusion of chronic myocardial infarction (MI) areas after local injections of autologous bone marrow stem cells (BMSCs). 14 coronary ligated rats with transmural chronic MI (4 months) were used: a control group (n = 7) versus a treated group (n = 7) in which (111)In labeled-BMSCs were directly engrafted on MI areas. By using (111)In/(99m)Tc SPECT and Sestamibi gated-SPECT,.
View Article and Find Full Text PDFPurpose: The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity.
Methods: The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving (201)Tl (n = 120) or (99m)Tc-sestamibi injected at low dose at stress ((99m)Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ((99m)Tc-High; rest/stress 1-day or 2-day protocol; n = 46).
Background: Tissue engineering scaffold constitutes a new strategy of myocardial repair. Here, we studied the contribution of a patch using autologous mesenchymal stem cells (MSCs) seeded on collagen-1 scaffold on the cardiac reconstruction in rat model of chronic myocardial infarction (MI).
Methods: Patches were cultured with controlled MSCs (growth, phenotype and potentiality).
Unlabelled: Differences in the performance of cadmium-zinc-telluride (CZT) cameras or collimation systems that have recently been commercialized for myocardial SPECT remain unclear. In the present study, the performance of 3 of these systems was compared by a comprehensive analysis of phantom and human SPECT images.
Methods: We evaluated the Discovery NM 530c and DSPECT CZT cameras, as well as the Symbia Anger camera equipped with an astigmatic (IQ x SPECT) or parallel-hole (conventional SPECT) collimator.
Background: Myocardial depression is a frequent event during septic shock and may mimic a cardiogenic shock state with decreased cardiac output. Nevertheless, data are scarce regarding the myocardial effects of vasopressors used to treat hypotension. In this study, the authors compared the effects of three commonly used vasopressors acting on different adrenergic receptors on myocardial function in a rodent model of septic shock, as explored with conductance catheter and positron emission tomography.
View Article and Find Full Text PDFObjective: Statistical Parametric Mapping (SPM) is widely used for the quantitative analysis of brain images from ¹⁸F fluorodeoxyglucose positron emission tomography (FDG PET). SPM requires an initial step of spatial normalization to align all images to a standard anatomic model (the template), but this may lead to image distortion and artifacts, especially in cases of marked brain abnormalities. This study aimed at assessing a block-matching (BM) normalization algorithm, where most transformations are not directly computed on the overall brain volume but through small blocks, a principle that is likely to minimize artifacts.
View Article and Find Full Text PDFRadiotherapy is an integral part of overall cancer therapy. One of the most serious adverse effects of irradiation concern, for long-term survivors, the development of post-radiation sarcoma (PRS) in healthy tissues located within the irradiated area. PRS have bad prognosis and are often detected at a late stage.
View Article and Find Full Text PDFThe rat myocardial infarction (MI) model is widely used to study left ventricular (LV) remodeling. In this study, acipimox-enhanced (18)F-Fluorodeoxyglucose (FDG) gated-positron emission tomography (PET) was assessed for characterizing and predicting early remodeling in the rat infarct model. Nineteen Wistar rats had surgical occlusion of the left anterior descending coronary artery and 7 were sham-operated.
View Article and Find Full Text PDF