Left ventricular assist devices (LVAD) are used in the treatment of advanced left ventricular heart failure. LVAD can serve as a bridge to orthotopic heart transplantation or as a destination therapy in cases where orthotopic heart transplantation is contraindicated. Ventricular arrhythmias are frequently observed in patients with LVAD.
View Article and Find Full Text PDFThe year 2023 marks 60 years since the first pacemaker was implanted in Poland. The number of implantable cardiac electrotherapy devices (CIEDs), including pacemakers, cardioverter-defibrillators, and resynchronization therapy systems, has been systematically increasing in the subsequent decades. It is estimated that nearly 500,000 Poles have an implanted cardiac electrotherapy device, making optimal diagnostic imaging with the use of magnetic resonance imaging (MRI) a clinically and epidemiologically important issue.
View Article and Find Full Text PDFHis-bundle pacing (HBP) is a relatively new method of cardiac pacing, with recent studies showing an association between HBP and a lower risk of developing right ventricular heart failure compared to classical pacing methods. However, HBP is also associated with a higher risk of lead dislodgement, undersensing, and loss of capture. As such, a detailed assessment of pacing effectiveness in pacemaker patients is vital.
View Article and Find Full Text PDFModern cardiac pacemakers are equipped with a function that allows the heart rate to adapt to the current needs of the patient in situations of increased demand related to exercise and stress ("rate-response" function). This function may be based on a variety of mechanisms, such as a built-in accelerometer responding to increased chest movement or algorithms sensing metabolic demand for oxygen, analysis of intrathoracic impedance, and analysis of the heart rhythm (Q-T interval). The latest technologies in the field of rate-response functionality relate to the use of an accelerometer in leadless endocavitary pacemakers; in these devices, the accelerometer enables mapping of the mechanical wave of the heart's work cycle, enabling the pacemaker to correctly sense native impulses and stimulate the ventricles in synchrony with the cycles of atria and heart valves.
View Article and Find Full Text PDFAssess the diagnostic value of 18-F FDG PET/CT in cardiac implantable electronic devices (CIED) infections in facilitating diagnostic process and optimizing decision-making process.Study group (n = 21) patients with initial suspected diagnosis of CIED-related infection or fever of unknown origin and patients referred for device removal due to infection. Control group (n = 13) patients with implanted CIED, who underwent PET/CT due to other non-infectious indications and had no data for infectious process in follow-up.
View Article and Find Full Text PDFSubcutaneous implantable cardioverter-defibrillators are a modern alternative to classic cardioverter-defibrillators. Prior to implantation of the device, qualification based on assessment of the heart's specific rhythm shape during a resting electrocardiogram examination must be performed. In the presented case, a patient with a subcutaneous implantable cardioverter-defibrillator experienced numerous discharges during exercise.
View Article and Find Full Text PDF