Background: The aim of the study was to validate a software-based planning method for the Schoettle Point and to evaluate precision and time efficiency of its live overlay on the intraoperative X-ray.
Methods: A software-based method was compared with surgeons' manual planning in an inter- and intrarater study. Subsequently, K-wire placement was performed with and without an overlay of the planning.
Background: For the temporary treatment of ankle fracture dislocations (AFDs), previous studies indicate higher rates of secondary loss of reduction (LOR) with splint immobilization, prompting consideration for expanding indications for external fixation (ExFix). However, these studies did not investigate the influence of fracture morphology to further improve patient selection. The aim of this study was to investigate the influence of Lauge-Hansen injury type on the LOR rate in bimalleolar or trimalleolar AFDs for temporary cast vs ExFix immobilization.
View Article and Find Full Text PDFBackground: Type C pelvic fractures (AO/OTA) are severe injuries that frequently lead to bleeding and hemodynamic instability. Pelvic binders play a crucial role in their initial management. Placement at the correct level in the prehospital setting is challenging.
View Article and Find Full Text PDFBackground: Medical photography plays a pivotal role in modern health care, serving multiple purposes ranging from patient care to medical documentation and education. Specifically, it aids in wound management, surgical planning, and medical training. While digital cameras have traditionally been used, smartphones equipped with specialized apps present an intriguing alternative.
View Article and Find Full Text PDFPurpose: Intraoperative 3D imaging has become a valued tool in assessing the quality of reduction and implant placement in orthopedic trauma surgery. In our institution, 3D imaging is used routinely since 2001. To evaluate the intraoperative findings and consequences of this technique, intraoperative revision rates in cases with 3D imaging were analyzed.
View Article and Find Full Text PDFIn clinical routine, wound documentation is one of the most important contributing factors to treating patients with acute or chronic wounds. The wound documentation process is currently very time-consuming, often examiner-dependent, and therefore imprecise. This study aimed to validate a software-based method for automated segmentation and measurement of wounds on photographic images using the Mask R-CNN (Region-based Convolutional Neural Network).
View Article and Find Full Text PDFIntroduction: Although intraoperative imaging is important for assessing the quality of several steps during fracture fixation, most trainees and surgeons have received little formal education on this topic and report they learn "on the job" and "through practice". A planning committee of orthopedic trauma surgeons was established to design a curriculum using "backward planning" to identify patient problems, identify gaps in surgeons' knowledge and skills, and define competencies as a framework for education in order to optimize patient care.
Materials And Methods: The committee defined 8 competencies related to intraoperative imaging, with detailed learning objectives for each one (e.
Background: Despite a substantial improvement in the operative treatment of tibial plateau fractures, the surgical procedure remains controversial and is generally challenging, as patients may develop postoperative arthritis and functional impairment of the knee joint.
Hypothesis: In the surgical treatment of tibial plateau fractures the intraoperative reposition quality has the greatest influence on the postoperative outcome, whereby misalignments of≥2mm lead to a worse result.
Patients And Methods: Forty-one patients with tibial plateau fractures were postoperatively examined.
The aim of our study was to evaluate whether software-based artifact reduction can achieve an improved image quality, using intraoperative 3D imaging in spinal surgery. A total of 49 intraoperative 3D image datasets of patients, who underwent surgery with pedicle screw placement, were retrospectively evaluated. The visibility of anatomical structures and the diameter of the pedicle screws were examined, with and without the application of the artifact reduction software.
View Article and Find Full Text PDFBackground: Currently available procedures for the treatment of minimally displaced acetabular fractures include conservative treatment and minimally invasive percutaneous screw fixation. Screw fixation of acetabular fractures allows patients' early full-weight bearing due to improved biomechanic stability. Can the range of motion, pain and mobility and quality of life in patients with acetabular fractures be improved by minimally invasive screw fixation, compared to conservative treatment in the long term?
Methods: Patients treated for a minimally displaced acetabular fracture, either conservatively or by closed reduction percutaneous screw fixation, in the period from 2001 to 2013 were included in this retrospective study.
Purpose: Acute unstable syndesmotic lesions are regularly treated with closed or open reduction and fixation with either a positioning screw or tight rope. Conventional fluoroscopy is limited to identify a malreduction of the ankle mortise. The aim of the study was to validate the reduction criteria of intraoperative cone beam CT in unstable syndesmotic injuries by analyzing the clinical outcome.
View Article and Find Full Text PDFIn order to achieve a clinically satisfying result and to prevent posttraumatic osteoarthritis in the treatment of unstable syndesmotic injuries, anatomically correct reduction is crucial. The objective of the study was to investigate three different reduction methods of the ankle mortise in unstable syndesmotic injuries. In a specimen model with 38 uninjured fresh-frozen lower legs, a complete syndesmotic dissection was performed.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
August 2021
Purpose: The aim of the study is to identify an ideal location to measure fibular rotation in the ankle joint using axial computed tomography (CT) scans. Another objective was to detect the average fibular rotation in the uninjured ankle joint in a large cohort.
Methods: Standardised axial CT with coronal/sagittal reconstructions was performed in healthy ankle joints.
The reconstruction of anatomical joint surfaces, limb alignment and rotational orientation are crucial in the treatment of fractures in terms of preservation of function and range of motion. To assess reduction and implant position intra-operatively, mobile C-arms are mandatory to immediately and continuously control these parameters.Usually, these devices are operated by OR staff or radiology technicians and assessed by the surgeon who is performing the procedure.
View Article and Find Full Text PDFBackground: A virtual guidance framework is used to assist the conventional method of virtual implant planning system (VIPS). The study null hypothesis was that its screw placement accuracy is equal to that of conventional VIPS.
Methods: In 34 distal radius sawbone models, 3D implant planning was performed.
Background: In acetabular fractures, the assessment of reduction and implant placement has limitations in conventional 2D intraoperative imaging. 3D imaging offers the opportunity to acquire CT-like images and thus to improve the results. However, clinical experience shows that even 3D imaging has limitations, especially regarding artifacts when implants are placed.
View Article and Find Full Text PDFBackground: The aim of this study is to determine the functional long-term outcome after non-operative and operative treatment of radial neck fractures in adults.
Methods: Thirty-four consecutive patients with a mean age of 46.4 (18.
Background: Indirect screw fixation of the sustentaculum tali in the lateral-medial direction can be challenging due to the complex calcaneal anatomy. A novel 2-dimensional (2D) projection-based software application detects Kirschner wires (K-wires) and visualizes their intended direction as a colored trajectory. The aim of this prospectively randomized cadaver study was to investigate whether the software would facilitate the indirect K-wire placement in the sustentaculum tali.
View Article and Find Full Text PDFBackground: The intraoperative assessment of the articular surface in displaced intra-articular distal tibia fractures can be challenging using conventional fluoroscopy. The aim of the study was to determine the frequency and the method of intraoperative corrections of fracture reductions or implant placements during open reduction, internal fixation by using cone beam computed tomography (CT) after conventional fluoroscopy.
Methods: Displaced intra-articular distal tibia fractures were retrospectively analyzed from August 2001 until December 2011.