Publications by authors named "Sven Clausen"

Background: Recent advancements in computed tomography (CT), notably in photon-counting CT (PCCT), are revolutionizing the medical imaging field. PCCT's spectral imaging can better visualize tissues based on their material properties. This research aims to establish a fundamental approach for the in vivo visualization of intracranial cerebrospinal fluid (CSF) using PCCT.

View Article and Find Full Text PDF

Background: Advances in computed tomography (CT) technology, particularly photon-counting CT (PCCT), are reshaping the possibilities for medical imaging. PCCT in spectral imaging enables the high-resolution visualization of tissues with material-specific accuracy. This study aims to establish a foundational approach for the in vivo visualization of intracranial blood using PCCT, focusing on non-enhanced imaging techniques and spectral imaging capabilities.

View Article and Find Full Text PDF
Article Synopsis
  • This study investigates using intraoperative radiotherapy (IORT) as an additional boost for high-risk breast cancer patients, combined with standard external beam radiotherapy (EBRT), and aims to evaluate treatment outcomes and side effects.
  • The study, known as TARGIT BQR, included 1133 patients across 10 centers from 2011 to 2020, assessing both acute and long-term toxicity following the IORT boost delivered immediately after tumor removal.
  • Findings showed that the IORT boost is feasible and generally safe, with low rates of serious side effects; however, some patients experienced mild to moderate acute and chronic effects such as erythema and fibrosis.
View Article and Find Full Text PDF

This brief report aimed to show the utility of photon-counting technology alongside standard cranial imaging protocols for visualizing shunt valves in a patient's cranial computed tomography scan. Photon-counting CT scans with cranial protocols were retrospectively surveyed and four types of shunt valves were encountered: proGAV 2.0, M.

View Article and Find Full Text PDF

This study provides an objective comparison of cranial computed tomography (CT) imaging quality and radiation dose between photon counting detectors (PCCTs) and energy-integrated detectors (EIDs). We retrospectively analyzed 158 CT scans from 76 patients, employing both detector types on the same individuals to ensure a consistent comparison. Our analysis focused on the Computed Tomography Dose Index and the Dose-Length Product together with the contrast-to-noise ratio and the signal-to-noise ratio for brain gray and white matter.

View Article and Find Full Text PDF

This study introduces an application of innovative medical technology, Photon Counting Computer Tomography (PC CT) with novel detectors, for the assessment of shunt valves. PC CT technology offers enhanced visualization capabilities, especially for small structures, and opens up new possibilities for detailed three-dimensional imaging. Shunt valves are implanted under the skin and redirect excess cerebrospinal fluid, for example, to the abdominal cavity through a catheter.

View Article and Find Full Text PDF

Detailed visualization of the cribriform plate is challenging due to its intricate structure. This study investigates how computed tomography (CT) with a novel photon counting (PC) detector enhance cribriform plate visualization compared to traditionally used energy-integrated detectors in patients. A total of 40 patients were included in a retrospective analysis, with half of them undergoing PC CT (Naeotom Alpha Siemens Healthineers, Forchheim, Germany) and the other half undergoing CT scans using an energy-integrated detector (Somatom Sensation 64, Siemens, Forchheim, Germany) in which the cribriform plate was visualized with a temporal bone protocol.

View Article and Find Full Text PDF

: The current prescription and the assessment of the delivered absorbed dose in intraoperative radiation therapy (IORT) with the INTRABEAM system rely mainly on depth-dose measurements in water. The accuracy of this approach is limited because tissue heterogeneity is ignored. It is also difficult to accurately determine the dose delivered to the patient experimentally as the steep dose gradient is highly sensitive to geometric errors.

View Article and Find Full Text PDF

Purpose: To design and manufacture a pelvis phantom for magnetic resonance (MR)-guided prostate interventions, such as MRGB (MR-guided biopsy) or brachytherapy seed placement.

Methods: The phantom was designed to mimic the human pelvis incorporating bones, bladder, prostate with four lesions, urethra, arteries, veins, and six lymph nodes embedded in ballistic gelatin. A hollow rectum enables transrectal access to the prostate.

View Article and Find Full Text PDF

Purpose: Robotic systems to assist needle placements for low-dose rate brachytherapy enable conformal dose planning only restricted to path planning around risk structures. We report a treatment planning system (TPS) combining multiple direction needle-path planning with inverse dose optimization algorithms.

Methods: We investigated in a path planning algorithm to efficiently locate needle injection points reaching the target volume without puncturing risk structures.

View Article and Find Full Text PDF

Clinical/methodological Issue: Multiparametric magnetic resonance imaging (mpMRI) of the prostate plays a crucial role in the diagnosis and local staging of primary prostate cancer.

Standard Radiological Methods: Image-guided biopsy techniques such as MRI-ultrasound fusion not only allow guidance for targeted tissue sampling of index lesions for diagnostic confirmation, but also improve the detection of clinically significant prostate cancer.

Methodological Innovations: Minimally invasive, focal therapies of localized prostate cancer complement the treatment spectrum, especially for low- and intermediate-risk patients.

View Article and Find Full Text PDF

Background: The spine is the most frequent location of bone metastases. Local treatment aims at palliation of pain and, given the increased likelihood of long-term cancer survival, at local control. Kyphoplasty and intraoperative radiotherapy (Kypho-IORT) provided instantaneous pain relief in 70% of patients at the first day after the intervention and resulted in local control rates of > 93% at 1 year in a recently conducted phase I/II trial.

View Article and Find Full Text PDF

Purpose: Partial breast irradiation using intraoperative radiotherapy (IORT) after breast-conserving surgery could be sufficient for a selected group of breast cancer patients. We report the results of a cohort of patients from a single center treated as part of the randomized phase-3 TARGIT-A trial.

Methods: Patients (≥50 years) with cT1 cN0 cM0 and invasive ductal histology on biopsy were randomized between IORT with 20 Gy (arm-A) or postoperative whole-breast RT (WBRT) up to 56 Gy in 2 Gy fractions (arm-B).

View Article and Find Full Text PDF

Background: The median time to recurrence of glioblastoma (GB) following multimodal treatment is ∼7 mo. Nearly all cancers recur locally, suggesting that augmenting local treatments may improve outcomes.

Objective: To investigate whether intraoperative radiotherapy (IORT) to the resection cavity is safe and effective.

View Article and Find Full Text PDF

Objective: Intraoperative radiotherapy (IORT) after surgical resection using a low-kV-X-ray source is a proven method used in cancer treatment. However, the shape and size of the targeted surface area are limited to the size of the available applicators. This can lead to nonconformal and therefore suboptimal treatment for many patients.

View Article and Find Full Text PDF

Background Context: Spinal metastases occur in 30%-50% of patients with systemic cancer. The primary goals of palliation are pain control and prevention of local recurrence.

Purpose: This study aimed to test the safety and efficacy of a combined modality approach consisting of kyphoplasty and intraoperative radiotherapy (Kypho-IORT).

View Article and Find Full Text PDF

Background: To the present date, IORT has been eye and hand guided without treatment planning and tissue heterogeneity correction. This limits the precision of the application and the precise documentation of the location and the deposited dose in the tissue. Here we present a set-up where we use image guidance by intraoperative cone beam computed tomography (CBCT) for precise online Monte Carlo treatment planning including tissue heterogeneity correction.

View Article and Find Full Text PDF

Patients diagnosed with glioblastoma multiforme receiving stereotactic biopsy only either due to tumor localization or impaired clinical status face a devastating prognosis with very short survival times. One strategy to provide an initial cytoreductive and palliative therapy at the time of the stereotactic biopsy is interstitial irradiation through the pre-defined trajectory of the biopsy channel. We designed a novel treatment planning system and evaluated the treatment potential of a fixed-source and a stepping-source algorithm for interstitial radiosurgery on non-spherical glioblastoma in direct adjacency to risk structures.

View Article and Find Full Text PDF

Background: Glioblastoma multiforme (GBM) is the most frequent primary malignant brain tumor in adults. Despite multimodal therapies, almost all GBM recur within a narrow margin around the initial resected lesion. Thus, novel therapeutic intensification strategies must target both, the population of dispersed tumor cells around the cavity and the postoperative microenvironment.

View Article and Find Full Text PDF

Purpose: Second cancer risk after breast conserving therapy is becoming more important due to improved long term survival rates. In this study, we estimate the risks for developing a solid second cancer after radiotherapy of breast cancer using the concept of organ equivalent dose (OED).

Materials And Methods: Computer-tomography scans of 10 representative breast cancer patients were selected for this study.

View Article and Find Full Text PDF

The use of IORT as a treatment modality for patients with close or positive margins has increased over the past decade. For situations where a flat area (up to 6 cm in diameter) has to be treated intraoperatively, new applicators for superficial treatment with a miniature X-ray source (INTRABEAM system) were developed. Here we report our evaluation of the dosimetric characteristics of these new applicators and their first clinical use.

View Article and Find Full Text PDF

Background: Intraoperative radiotherapy (IORT) using the INTRABEAM(®) system promises a flexible use regarding radiation protection compared to other approaches such as electron treatment or HDR brachytherapy with (192)Ir or (60)Co. In this study we compared dose rate measurements of breast- and Kypho-IORT with C-arm fluoroscopy which is needed to estimate radiation protection areas.

Materials And Methods: C-arm fluoroscopy, breast- and Kypho-IORTs were performed using phantoms (silicon breast or bucket of water).

View Article and Find Full Text PDF