Background: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is increasingly being used for temporary bleeding control in patients with trauma with non-compressible truncal hemorrhage (NCTH). In recent years, the technique is gaining popularity in postpartum hemorrhage and non-traumatic cardiac arrest, although still underutilized. In other surgical fields, however, there is not yet much awareness for the possible advantages of this technique.
View Article and Find Full Text PDFBackground: Technology improves accessibility of psychological interventions for youth. An ecological momentary intervention (EMI) is a digital intervention geared toward intervening in daily life to enhance the generalizability and ecological validity, and to be able to intervene in moments most needed. Identifying working mechanisms of the use of ecological momentary interventions might generate insights to improve interventions.
View Article and Find Full Text PDFBackground: Truncal and junctional hemorrhage is the leading cause of potentially preventable deaths in trauma patients. To reduce this mortality, the application of advanced bleeding control techniques, such as resuscitative endovascular balloon occlusion of the aorta (REBOA), junctional tourniquets, Foley catheters, or hemostatic agents should be optimized. This study aimed to identify trauma patients with non-compressible truncal and junctional hemorrhage (NCTJH) who might benefit from advanced bleeding control techniques during initial trauma care.
View Article and Find Full Text PDFJ Trauma Acute Care Surg
April 2023
Background: Prompt bleeding control in the prehospital phase is essential to improve survival from catastrophic junctional hemorrhage. This study aimed to compare the effectiveness and practicality of Foley catheter balloon tamponade (FCBT), Celox-A, and XSTAT for the treatment of catastrophic hemorrhage from penetrating groin injuries with a small skin defect in a live-tissue porcine model. In addition, this study aimed to determine whether a training program could train military personnel in application of these advanced bleeding control adjuncts.
View Article and Find Full Text PDFIntroduction: Prompt and effective hemorrhage control is paramount to improve survival in patients with catastrophic bleeding. In the ever-expanding field of bleeding control techniques, there is a need for a realistic training model to practice these life-saving skills. This study aimed to create a realistic perfused post-mortem human specimen (PMHS) flow model that is suitable for training various bleeding control techniques.
View Article and Find Full Text PDFPurpose: To gain insight into anatomical variations between sexes and different age groups in intraluminal distances and anatomical landmarks for correct insertion of resuscitative endovascular balloon occlusion of the aorta (REBOA) without fluoroscopic confirmation.
Materials: All non-trauma patients receiving a computed tomography angiography (CT-A) scan of the aorta, iliac bifurcation and common femoral arteries from 2017 to 2019 were eligible for inclusion.
Methods: Central luminal line distances from the common femoral artery (CFA) to the aortic occlusion zones were measured and diameters of mid zone I, II and III were registered.
Background: Hemorrhage from truncal and junctional injuries is responsible for the vast majority of potentially survivable deaths in combat casualties, causing most of its fatalities in the prehospital arena. Optimizing the deployment of the advanced bleeding control modalities required for the management of these injuries is essential to improve the survival of severely injured casualties. This study aimed to establish consensus on the optimal use and implementation of advanced bleeding control modalities in combat casualty care.
View Article and Find Full Text PDFPurpose: Use of Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) as adjunct for temporary hemorrhage control in patients with exsanguinating torso hemorrhage is increasing. Characteristics of aortic occlusion balloons (AOB) are diverse and evolving as efforts are made to improve the technology. It is important to select a device that fits the requirements of the medical situation to minimize the risk of failure and complications.
View Article and Find Full Text PDF