Orthodontic implants may fracture at the cortical bone level upon rotational torque. The impacted fragment can be detached by a range of methods, which are all more or less time-consuming and injurious to the cortical bone. The aim of this study was to compare three different methods for detaching an orthodontic implant impacted in cortical bone.
View Article and Find Full Text PDFWe investigated the effects of CO2 laser irradiation combined with acidulated phosphate fluoride (APF) application on the demineralization of enamel. APF gel was applied to the buccal enamel of human premolars and CO2 laser was applied. After the specimens were immersed in demineralization solution for 72 h, they were subjected to depth-dependent micro-CT and nanoindentation analyses.
View Article and Find Full Text PDFThis study investigated the effect of immediate force on bone adaptations surrounding miniscrew implants. Ten miniscrew implants were placed on the mandibles in three beagle dogs. Five pairs of miniscrew implants were immediately loaded with 150 g of continuous force using nickel-titanium coil springs for 8 weeks.
View Article and Find Full Text PDFIn this work, a bioactive glass was deposited on the alumina disk specimens by radio-frequency magnetron sputtering to study crystal formation ability in artificial saliva. Bioactive glass-coated specimens were immersed in artificial saliva for 1 week and 6 months. The specimens were observed with a scanning electron microscope (SEM) and the composition was determined by energy dispersive spectroscopy (EDS).
View Article and Find Full Text PDFThis study investigated fluoride release, acid resistance and shear bond strength (SBS) of new 4-META/MMA-TBB-based fluoride-containing resin adhesive (Super-Bond/F3). Super-Bond, Transbond Plus and Fuji Ortho LC were selected for comparison. Fluoride release into distilled water during 6-month period was measured using disk-shaped specimens.
View Article and Find Full Text PDFThis study examined the influence of the quantity and quality of cortical bone on the failure force of miniscrew implants. Twenty-six titanium alloy miniscrew implants (AbsoAnchor) 1.4mm in diameter and 5 or 7 mm long were placed in cross-sectioned maxillae (n = 6) and mandibles (n = 20) of human cadavers.
View Article and Find Full Text PDFThe aim of this study was to investigate the effect of immediate loading on the biomechanical properties of bone surrounding a miniscrew implant. Forty titanium alloy miniscrew implants were placed on the buccal side of the maxillae and mandibles in four beagle dogs. Twelve pairs of miniscrew implants were immediately loaded with approximately 150 g of continuous force using nickel-titanium coil springs and the remaining 16 implants were left unloaded for 8 weeks.
View Article and Find Full Text PDFObjective: To determine if a new experimental resin-based material containing Portland cement (PC) can help prevent enamel caries while providing adequate shear bond strength (SBS).
Materials And Methods: Brackets were bonded to human premolars with experimental resin-based adhesive pastes composed of three weight rations of resin and PC powder (PC 30, 7:3; PC 50, 5:5; PC 70, 3:7; n = 7). Self-etching primer (SEP) adhesive (Transbond Plus) and resin-modified glass ionomer cement (RMGIC) adhesive (Fuji Ortho FC Automix) were used for comparison.
This study investigated the effects of a diamond-like carbon (DLC) coating on frictional and mechanical properties of orthodontic brackets. DLC films were deposited on stainless steel brackets using the plasma-based ion implantation/deposition (PBIID) method under two different atmospheric conditions. As-received metal brackets served as the control.
View Article and Find Full Text PDFObjective: To determine the effect of coating on the properties of two esthetic orthodontic nickel-titanium wires.
Materials And Methods: Woowa (polymer coating; Dany Harvest) and BioForce High Aesthetic Archwire (metal coating; Dentsply GAC) with cross-section dimensions of 0.016 × 0.
Objective: To determine if the enamel around orthodontic brackets is significantly altered after demineralization followed by application of adhesives with and without fluoride-releasing ability.
Materials And Methods: One hundred eight noncarious human premolars were divided into six groups of 18 each and exposed to a demineralization solution. Stainless steel brackets were bonded using two conventional composite resin etch-and-rinse systems, three self-etching primer (SEP) composite resin systems, and one resin-modified glass ionomer cement (RMGIC) system.