Statement Of Problem: There are no data available on whether or to what extent hydrofluoric acid affects the marginal integrity of dentin-bonded composite restorations when it is used instead of phosphoric acid in the total-etch technique.
Purpose: This in vitro study examined the etching effects of phosphoric acid versus a combination of phosphoric and hydrofluoric acid by evaluation of microleakage in a composite restoration bonded with different dentin adhesive systems.
Material And Methods: Extracted teeth (n = 90) containing 2 class II preparations, mesial occlusal (MO) and distal occlusal (DO) standarized (cervical margins in dentin) were perfused with Ringer solution and etched in 1 of 2 ways: with phosphoric acid only or with phosphoric combined with hydrofluoric acid.
Statement Of Problem: There is no evidence-based information on how ceramic restorations with an adhesive bond between restoration material and composite cement may be influenced by a silicone disclosing agent.
Purpose: The aim of this study was to determine the effects of the silicone disclosing procedure on the shear bond strength of composite cements in the luting of industrial sintered and laboratory sintered ceramic restorations.
Material And Methods: Thirty standardized (15 x 10 x 9 mm) prefabricated ceramic specimens (Groups 1, 3, 5) and 30 standardized (15 x10 x 9 mm) conventionally sintered ceramic specimens (Groups 2, 4, 6) were roughened with sandpaper (800-grit).
This investigation was designed to test the cellular toxicity of two medicated (Roeko activ point and Roeko Calcium Hydroxide) and four nonmedicated brands of gutta-percha (GP) points (Antaeos, DeTrey White, Roeko color, and Roeko Top color). The test points were transferred into a culture medium including the GP-point material with a concentration of 6 mg/ml, and eluates were obtained after 72 h. Five milliliters of each eluate were pipetted onto fibroblast cultures, incubated, and subsequently stained.
View Article and Find Full Text PDFThis study investigated changes in the dimensions of Class II cavities following the removal of amalgam, glass ionomer and compomer restorations. In 30 extracted caries-free human molars, preparation for 60 mesio-occlusal and occluso-distal cavities (two cavities per tooth) occurred. With a CEREC 3 laser triangulation sensor and software-based construction analysis, the dimensions of the cavities at seven defined sites were measured.
View Article and Find Full Text PDFThe present investigation was designed to test cellular toxicity of modern dentin adhesives. With the use of the products Ariston Liner, Etch & Prime 3.0, Optibond Solo, Prime & Bond NT, Scotchbond 1, and Syntac Sprint, test specimens were prepared according to the manufacturers' instructions and transferred into a culture medium.
View Article and Find Full Text PDF